All Categories
History
Response Rate
100.0%
Response Time
8.6hours
Fast Response
Product
Instrumentation system equipment differential pressure/pressure transmitter EJX110L wireless battery-powered typeHandling Company
Yonei Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Static pressure accuracy (EJX110L) | Explosion-proof structure | Long-term stability (zero point) | Communication speed | Communication protocol | Diagnostic function | Accuracy | Wireless module compliance standards | Wireless security | Update cycle | Wetted temperature | External power drive | External zero adjustment mechanism | Frequency band | Ambient humidity | Ambient temperature | Output power | Output mode | Protection class | Working pressure | General safety standards | Battery pack | Software download function | Zero point transition possible range | Antenna | EMC compliance standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
EJX110L |
Available upon quote |
±0.5% |
TIIS Intrinsically Safe |
±0.1% / 1 year |
250kbps |
Compatible with ISA100.11a (IEEE802.15.4) |
Capsule abnormality, amplifier abnormality, process abnormality (device specification range exceeded), set value abnormality, remaining battery level, wireless communication abnormality. |
±0.1% |
This product uses specified radio equipment (certification number: 007WWCUL0480) that has received technical standards compliance certification based on the Radio Law. |
AES 128bit encryption |
Set in the range of 0.5 seconds ~ 60 minutes |
-40 ~ 120°C (general type) |
Rated voltage: 10.5 ~ 30VDC |
Continuously variable. The amount of zero point transition changes depending on the speed at which the zero adjustment shaft is turned. |
2,400 - 2,83.5MHz |
0~100%RH |
-40 ~ 85 °C |
Maximum 11.6dBm (fixed) |
Proportional/square root selection |
IP66/IP67, NEMA4X |
2.7kPa abs or more |
EN61010-1, EN61010-2-030 |
Uses 2 lithium thionyl chloride batteries |
It is possible to update the software inside wireless field devices via ISA100.11a wireless communication. |
Both the negative direction transition amount and the positive direction transition amount can be set as long as the lower and upper limits of the measurement range do not exceed the measurement range of each capsule. |
#ERROR! |
EEN61326-1 Class A, Table 2 (industrial use), EN61326-2-3 |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
8.6hrs