All Categories
History
Product
A flow rate monitor suitable for monitoring circulating cooling water and water-soluble coolant liquid for the FA industry.Capacitive electromagnetic flow monitor FMO (FMO) CXHandling Company
Aichi Watch Electric Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply | Piping characteristics | Measuring fluid | Display Display update count | Display Integrated flow rate display | Display Integrated flow rate unit | Display Instantaneous flow rate unit | Repeatability | Accuracy guaranteed flow range | Instantaneous flow rate display | Temperature characteristics Fluid temperature | Temperature characteristics Ambient temperature | Fluid temperature range | Fluid conductivity range | Detection method | Maximum working pressure | Responsiveness (damping time) | Pressure loss (at maximum flow rate with guaranteed accuracy) | Caliber | Storage ambient temperature range | Operating ambient temperature/humidity range | Low flow cutoff flow rate (3% of flow range maximum flow rate) | Main screen | Switch output | Switch input short circuit current | Switch input input time | Sub screen | Cable (accessory) | Analog output voltage/current | LED display |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX10 |
Available upon quote |
24V DC±10%, ripple P-P±10% or less |
・±5.0%F.S. |
Conductive fluid that does not corrode wetted parts (cold and hot water, etc.) |
5 times/sec |
4 digit display |
Standard settings: L, kL, ML (selection), special settings: gal, kgal, Mgal |
Standard setting: L/min, special setting: gal/min |
±2.0%F.S. |
0.5~15L/min |
0.0~18L/min |
±5.0%F.S. (Relative error of fluid temperature 1℃ or 85℃ with respect to standard fluid temperature 25℃) |
±5.0%F.S. (Relative error of ambient temperature 10℃ and 50℃ with respect to standard ambient temperature 25℃) |
0~+85℃ (Do not freeze) |
5μS/cm~3mS/cm |
Capacitive electromagnetic |
0~1.0MPa (0~+85℃), 0~2.0MPa (0~+50℃) |
63% response to step input Can be set from 0.25, 0.5, 1, 2, 5s (Standard: 1s) |
20kPa or less |
10mm |
-10~+60℃ |
0~+50℃ 35~85%RH (no condensation) |
0.45L/min |
Instantaneous flow rate value or total integrated value display |
・NPN or PNP transistor output *Please select when ordering |
Approximately 2mA DC |
20ms or more |
Output mode, input mode, flow direction, arbitrary characters (selection) |
Cable length: Approximately 3m (with the end coated removed) Outer diameter φ6.7 Connector: M12 |
1~5V DC load impedance: 50kΩ or more or 4~20mA DC load impedance: 500Ω or less *Please select when ordering |
Main screen: 4 digits, 7 segments (green/red two-color display) Sub screen: 6 digits, 11 segments (white) |