All Categories
History
Product
Ultrasonic flow meter for fuel gas management (screw connection) ATZTA UX40/50Handling Company
Aichi Watch Electric Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply | Piping connections | Compatible standards | Mass | Accuracy | Gas type to be measured | Temperature and pressure correction | Flow rate range (actual flow rate) City gas, nitrogen, argon | Flow range (actual flow rate) Butane/Propane | Fluid temperature | Maximum working pressure | Conversion accuracy | Output communication | Output analog | Protective structure | Operating environment temperature and humidity | Main display | Sub display section | Dc power supply | AC power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
UX40 |
Available upon quote |
Dedicated lithium battery (5 years life at 20℃, 65%RH) |
Screwed in, Rc1・1/2 |
CE/UKCA *Only compatible with battery/DC power type. However, it does not comply with the ATEX (Explosion Protection) Directive (2014/34/EU). |
Approximately 4.7kg |
・Qmax~Qmax/10: ±4%RD |
City gas (13A), butane (70% butane, 30% propane), propane (98% propane, 2% butane), nitrogen, argon |
Without (actual flow rate type), with (normal/standard conversion) |
1.6~80m3/h |
1.6~80m3/h |
-10~+60℃ No freezing |
100kPa |
±1.5%RD (at 23℃, 100kPa) |
- (Power supply only) Compliant with RS485 Modbus/RTU |
・ (Power supply only) 4~20mADC: Load resistance 400Ω or less |
Indoor/Outdoor IP64 (JIS C 0920) |
-10~+60℃ 90%RH or less No condensation |
・Accumulated flow rate (actual flow rate) 8 digits integer, 2 digits decimal, (converted flow rate) 8 digits integer, 1 digit decimal, (Trip total) 7 digits integer, 2 digits decimal |
Instantaneous flow rate: 5 digits Temperature: 3 digits Pressure: 5 digits |
24VDC±10% 2W or less (at voltage 26.4V current output 22mA) |
100VAC±15% 10W or less (at current output 22mA) |