Ultra-high-efficiency air cooling/heating The definitive solution for CO2 reduction/decarbonization, extreme heat countermeasures, and BCP countermeasures. Demand-kun HYPER-DMDHYP-01
Ultra-high-efficiency air cooling/heating The definitive solution for CO2 reduction/decarbonization, extreme heat countermeasures, and BCP countermeasures. Demand-kun HYPER-MDI Co., Ltd.

Ultra-high-efficiency air cooling/heating The definitive solution for CO2 reduction/decarbonization, extreme heat countermeasures, and BCP countermeasures. Demand-kun HYPER
MDI Co., Ltd.

MDI Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

47.3hours


About This Product

■When using well water or tap water

Using water at 15℃ and only 30 liters/minute provides the following effects. ・32℃ air → dehumidified air conditioner outputs 22℃ cold air ・-24.7KW air conditioner ・No air conditioner required + zero humidification ・Large air volume 6,000m3/h + dehumidification cooling ・Power consumption 600W ・COP40 Even using chiller water, power consumption is reduced by 18 to 30% compared to air conditioners. By using the cooling tower return water at 25°C, air that is below 5°C in winter can be output to 18~21°C. Seawater, hot spring water, sewage heat, geothermal heat, and exhaust heat can also be used.

■Characteristics/Design philosophy

・A water/antifreeze heat exchanger is included to prevent water scale and slime. ・For air side dirt cleaning, aluminum corrosion-free cleaning liquid [Dynamic GCS] is used, and the fin design is strong enough to be used for jet cleaning. ・Large air volume fan ・Movable, can be used in both summer and winter

■Main uses

・Well water heat source dehumidification cooling/boiler feed water heating ・Heating assistance by using cooling water at 25℃ in winter - Cooling assistance by using tap water at 22℃ in summer ・Ultra high efficiency air conditioning using chiller water at 7℃ ・Heat exchanger for heat source for heat pump ・Cold air device for preventing pinholes in corrosive environments ・Large factories, around heating furnaces ・Gymnasium, facilities, indoor parking lot ・Installed at the air handle inlet for pre-cooling and pre-heating ・Exhaust gas heat recovery ・Odor removal effect due to condensation ・For steam and steam heat recovery

  • Product

    Ultra-high-efficiency air cooling/heating The definitive solution for CO2 reduction/decarbonization, extreme heat countermeasures, and BCP countermeasures. Demand-kun HYPER

Share this product


30+ people viewing

Last viewed: 5 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Ultra-high-efficiency air cooling/heating The definitive solution for CO2 reduction/decarbonization, extreme heat countermeasures, and BCP countermeasures. Demand-kun HYPER

Image Part Number Price (excluding tax) Power supply Operating sound (dB) Design temperature (℃) Design pressure (mpaG) Air flow rate (m3/h) Kinds Full water mass (kg) Water side pressure loss (kPa) Material Air heat exchanger Material Water heat exchanger Material Antifreeze Material fan Material saddle External dimensions (mm) Total power consumption (kW) Available water volume L/min. Dry mass (kg) Maintenance service (optional) Optional parts and specifications
Ultra-high-efficiency air cooling/heating The definitive solution for CO2 reduction/decarbonization, extreme heat countermeasures, and BCP countermeasures. Demand-kun HYPER-Part Number-DMDHYP-01

DMDHYP-01

Available upon quote

3 phase 200V

50~72

0~60

0.4

6,000 (during load operation)

Water heat source temperature control device

178

4~120

Aluminum

SUS316/with copper brazing

LLC coolant

Iron + painting

Iron + painting

W816×D650×1,397

600~800W (varies depending on fan model selection and rotation speed)

10~60
Optional heat exchanger available to handle water quality and dirt

158

・Water heat exchanger cleaning, inspection, and replacement
・Air heat exchanger cleaning, inspection, antifreeze replacement
・Fan inspection and replacement
・Pump inspection and replacement

・Change of fan shape and wind output direction
・Changing the material, shape, and capacity of the water heat exchanger
・Fan circulator cover
・Automatic temperature adjustment control (fan control)
・Construction of chiller or exhaust heat recovery system

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Heat Exchangers Products

Other products of MDI Co., Ltd.

Reviews shown here are reviews of companies.


View more products of MDI Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

47.3hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree