All Categories

History

Spectrometer/Spectrometer Highly sensitive, high performance spectrometer (including for Raman spectroscopy measurement) Spectrometer for Brillouin scattering measurement Brillouin HYPERFINE-HF-8999-488-AUTO
Spectrometer/Spectrometer Highly sensitive, high performance spectrometer (including for Raman spectroscopy measurement) Spectrometer for Brillouin scattering measurement Brillouin HYPERFINE-Tokyo Instruments, Inc

Spectrometer/Spectrometer Highly sensitive, high performance spectrometer (including for Raman spectroscopy measurement) Spectrometer for Brillouin scattering measurement Brillouin HYPERFINE
Tokyo Instruments, Inc

Tokyo Instruments, Inc's Response Status

Response Rate

100.0%

Response Time

30.7hours

Relatively Fast Response


About This Product

■Spectrometer for Brillouin scattering measurement Brillouin HYPERFINE

Ultra-high resolution sub-GHz, equipped with laser line removal function, PC-controlled alignment

■Spectrometer for Brillouin scattering measurement "Brillouin HYPERFINE" Product overview

This product from LightMachinery is a specially designed spectrometer developed to measure, with ultra-high resolution, Brillouin scattered light, where excitation laser light interacts with sound waves in materials and is scattered with a slight frequency shift. It's a vessel. Inside the main body of the spectrometer, there is a spectroscopic optical system with "Brillouin VIPA (Virtually Imaged Phased Array) technology" (patented) that enables ultra-high resolution sub-GHz resolution measurements, and a spectroscopic optical system that cuts the excitation laser beam with high precision. It has a built-in "double-pass Fabry-Perot etalon optical system (Green Killer)" for this purpose. Brillouin scattered light observed in the vicinity of the excitation laser wavelength becomes difficult to measure if the excitation laser is not sufficiently removed if the reflected light from the opaque sample surface is strong. Therefore, by adding an external Green Killer unit as a separate option, it is possible to build an optical system that passes through the excitation laser cutting optical system a total of two times, resulting in a design that can handle even higher-level laser line removal. I am. Excitation wavelengths can be selected from four types: 488nm, 532nm, 660nm, and 780nm. In addition to the standard 1GHz resolution, you can choose from 0.6GHz, 0.3GHz (488nm/532nm), or 0.25GHz (660nm/780nm). The wavelength range for simultaneous measurement in one shot is >2 THz, making it possible to measure a wide range of wavelengths. We also support the design of 2D mapping systems by special order. Special optical design for Buroulian scattering measurements

■Main body

Built-in patented VIPA technology optics and double-pass Fabry-Perot etalon optics (Green Killer).

■External excitation laser removal Green Killer unit

Further options can be added. It is designed to handle high-level laser line removal.

  • Product

    Spectrometer/Spectrometer Highly sensitive, high performance spectrometer (including for Raman spectroscopy measurement) Spectrometer for Brillouin scattering measurement Brillouin HYPERFINE

Share this product


50+ people viewing

Last viewed: 2 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Spectrometer/Spectrometer Highly sensitive, high performance spectrometer (including for Raman spectroscopy measurement) Spectrometer for Brillouin scattering measurement Brillouin HYPERFINE

Image Part Number Price (excluding tax) Equipment size, weight Excitation wavelength filter suppression Excitation light suppression filter width Excitation light suppression filter variable range Excitation laser wavelength Resolution selection Input method Dynamic range (@6GHz) Interface Option
Spectrometer/Spectrometer Highly sensitive, high performance spectrometer (including for Raman spectroscopy measurement) Spectrometer for Brillouin scattering measurement Brillouin HYPERFINE-Part Number-HF-8999-488-AUTO

HF-8999-488-AUTO

Available upon quote

71×71×15 cm, 25 kg

>30dB

0.5pm

±1 nm

488nm

1GHz (FSR 50GHz)
0.6 GHz (FSR 30GHz)
0.3 GHz (FSR 15GHz)

Single mode fiber launch

Effective contrast at 6 GHz is >80 dB (or >110 dB with additional external GK)

USB3.1

External GreenKiller unit
HF-10237-488-AUTO

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Spectroscopes Products

Other products of Tokyo Instruments, Inc

Reviews shown here are reviews of companies.


View more products of Tokyo Instruments, Inc

About Company Handling This Product

Response Rate

100.0%


Response Time

30.7hrs

Company Overview

Tokyo Instruments, Inc., established in 1981, and headquartered in Tokyo, Japan, is a manufacturer of opto-ele...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree