All Categories

History

Cylinder switch for hydraulic/pneumatic equipment Magnetic proximity type/non-contact (cutting oil resistant specification) WS type-WS215 (flex tube type)
Cylinder switch for hydraulic/pneumatic equipment Magnetic proximity type/non-contact (cutting oil resistant specification) WS type-TAIYO Co., Ltd.

Cylinder switch for hydraulic/pneumatic equipment Magnetic proximity type/non-contact (cutting oil resistant specification) WS type
TAIYO Co., Ltd.

TAIYO Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

43.2hours


About This Product

■Notes

- Connect correctly according to the color coding of the lead wires. When making connections, be sure to turn off the device power to the electrical circuit to be connected. Incorrect wiring or short-circuiting of the load may cause damage to the switch and load-side electrical circuit. Even a momentary short circuit can lead to burnout of the output circuit. Additionally, working while the power is on may cause damage to the switch and load-side electrical circuit. - Separate the switch cord from the power source of other electrical equipment as much as possible. If wires are bundled or wired close together, induced current will adversely affect the switch and load. Output protection circuit

■When connecting and using inductive loads (relays, solenoid valves, etc.)

A surge voltage is generated when the switch is OFF, so be sure to provide a protection circuit on the load side.

■When connecting a capacitive load (capacitor, etc.) or extending the cord over 10m

An inrush current will occur when the switch is turned on, so be sure to install a protection circuit (resistor or choke coil) as shown in the diagram.

■Wiring

Do not apply any load to the switch cord, such as bending or pulling it. In particular, take measures such as fixing the switch cord so that no load is applied to the base of the switch cord.

■Detectable cylinder piston speed

- When setting the switch to an intermediate position, please keep the cylinder maximum speed within 300mm/s due to the response speed of load relays, etc. ・Please note that if the piston speed is too fast, the switch will operate, but the time the switch will operate will be short and loads such as relays may not operate.

■Installation location

・In locations where strong magnetic fields are generated in the surrounding area, provide a magnetic shield with an iron plate, etc. - Do not bring ferromagnetic materials (such as iron) close to the outer circumference of the cylinder body or near the switch. As a guide, keep the distance approximately 20mm apart. - Do not use in locations where the switch and wiring may be submerged in water or oil. Please install with care.

  • Product

    Cylinder switch for hydraulic/pneumatic equipment Magnetic proximity type/non-contact (cutting oil resistant specification) WS type

Share this product


40+ people viewing

Last viewed: 11 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Cylinder switch for hydraulic/pneumatic equipment Magnetic proximity type/non-contact (cutting oil resistant specification) WS type

Image Part Number Price (excluding tax) Applicable load Load voltage/current Indicator light Withstand voltage Shockproof Vibration resistance Insulation resistance Wiring method Leakage current Response time Hysteresis Ambient temperature Internal voltage drop Protection method Format
Cylinder switch for hydraulic/pneumatic equipment Magnetic proximity type/non-contact (cutting oil resistant specification) WS type-Part Number-WS215 (flex tube type)

WS215 (flex tube type)

Available upon quote

Small relay
programmable controller

DC10~30V・6~20mA

Operating range: red light emitting diode lighting
Optimal position: Green light emitting diode lights up

AC1,500V, no abnormality for 1 minute
(between case and code)

490m/s2
(non-repeat)

Double amplitude 0.6mm, 10~200Hz
1 hour log sweep in each direction of X, Y, Z

DC500V mega time MIN.100MΩ or more
(between case and code)

0.3㎟, 2 cores, outer diameter φ4mm
Oil-resistant cabtire cord

1mA or less

1ms or less

1mm or less

-10~+60℃
(However, no freezing)

4V or less

IP67G (JEM standard) (oil resistant)

With cord (5m)

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Magnetic Sensors Products

Other products of TAIYO Co., Ltd.

Reviews shown here are reviews of companies.


View more products of TAIYO Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

43.2hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree