All Categories
History
Response Rate
100.0%
Response Time
39.1hours
Product
Batch counter CU-675Handling Company
U-Inix Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Measurement display range | Measurement error display | Display accuracy (integration) | End signal display | Deceleration signal display | Normal stop display | Decimal point display | Control signal display | Deviation error display | Signal output end signal | Signal output Deceleration signal | Signal output Control signal | Signal input Abnormal signal | Signal input Reset signal | Signal input Stop signal | Signal input Start signal | Manual display | Sensor power supply | Sensor input abnormality detection | Sensor input response | Sensor input signal | Scaling (converted value) | Overrun correction | Analog input display | TOTAL indicator | SV setting range | SV display (target value) | PV display (measured value) | PV display reset | CH display |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CU-675 |
Available upon quote |
0~999,999 |
ALM lamp lights up (red 3φLED) |
Scaling (converter) ±0 at 1 (current position correction display, when function is stopped) |
END lamp lights up (green 3φLED) |
SLW lamp lights up (green 3φLED) |
STP lamp lighting (green 3φLED) |
Display can be selected from 1 to 3 digits after the decimal point |
RUN lamp lights up (green 3φLED) |
STS lamp lighting (red 3φLED) |
Relay 1a contact output AC 250V (DC30V) 3A MAX (resistive load) |
Relay 1c contact output AC 250V (DC30V) 5A MAX (resistive load) |
Relay 1c contact output AC 250V (DC30V) 5A MAX (resistive load) |
Sink current: MIN 10mA or more |
Terminal block input is ON for 100ms or more |
Accepts NPN open collector output or contact output |
Terminal block input is ON for 100ms or more |
MAN lamp lights up (orange 3φLED) |
DC +12V (±10%) 100mA MAX (regulated) |
If the set number of pulses are not input within the set time, a measurement error signal is output, the measurement error display (ALM) is lit, and batch control is stopped. |
LOW: 0.01Hz ~ 50Hz |
NPN open collector pulse: MIN 10mA or more (sink current) |
Arbitrary setting of magnification per signal from 1×10^-9 to 9,999 |
Correct values that exceed the SV value (target value) |
ANA lamp lights up (orange 3φLED) |
Upper row: 6 digit red LED, character height 10mm |
0~999,999 |
Lower row: 6 digits red LED, character height 8mm |
Middle row: Red LED 6 digits, character height 10mm |
(When selecting reset start) |
Lower row: Red LED 1 digit, character height 8mm |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
39.1hrs