Meter relay for analog input SP-323Handling Company
U-Inix Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Alarm output method | Alarm output comparison method | Alarm output maximum rating | Alarm output output mode | Measurement type | Measurement method | Display | Display switching | Instantaneous display accuracy | Instantaneous display range | Instantaneous display sampling time | Instantaneous display Area zero display function | Instantaneous display Least significant digit | Instantaneous display Decimal point position | Instantaneous display Zero adjustment function | Instantaneous display scaling | Instantaneous display Over display | Percentage display range | Percentage display lamp | Percentage display Conversion method | Percentage display Over display | Linearization setting method | Linearize function selection | Sensor input temperature characteristics | Sensor input method | Sensor input disconnection detection function | Sensor supply power | Sensor GND switching selection | EXT input signal | EXT input operation selection |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SP-323 |
Available upon quote |
Relay 1c contact output (×2) |
Compare display value and preset value |
[Rated control capacity/maximum allowable power] |
Select from Compare/Keep |
Instant measurement (displays proportional to input voltage and current) |
A/D conversion method |
Red LED 5 digits Character height: 14mm |
Instantaneous display, percentage display |
For full scale span analog input, |
(-4) -9,999~9,999 |
Averaged over 0.1 seconds ~ 10.0 seconds |
Displays “0” between two arbitrarily set display points. (Requires setting in “Mode No. 1” scaling setting area zero minimum/maximum display) |
Usually 0 (fixed), 0 or 5 |
(-4) 10^-1, 10^-2, 10^-3, none |
If you press the "Shift" key + "Up" key for more than 2 seconds while the measurement is displayed, the current display will be adjusted to "0" (setting is required in "Mode No. 3") |
Set analog minimum/maximum input value and minimum/maximum display value |
(-4) "-9,999" or "9,999" flashing OV lamp lit |
-999.9~999.9 |
Lights up while displaying the percentage display value (switch to instantaneous display using the "Enter" key on the front panel) |
Display scaling conversion between two points of instantaneous display value at 0.0% and 100.0% |
-999.9" or "999.9" flashes OV lamp lights up |
Broken line approximate value (21ch setting possible) |
Select enable/disable of linearize function (select with “Mode No.0”) |
A2~A6 type: ±50ppm/℃ (0 ~ 50℃) |
Select from A2~A7 types (see analog input options) |
When "input signal ≦ -20%F.S.", it is determined that the wire is disconnected, and "- - - - -" flashes on both the instantaneous display and percentage display (valid for A2 and A3 types) |
DC 24V (±5%) 150mA |
Short/open switching between terminal 9 (LO) and terminal 7 (sensor power supply GND) can be selected using the sensor GND selection switch (only for A2 to A5 types) |
NPN open collector or contact output (HD lamp lights up when ON) |
Display hold, peak hold, bottom hold, input width display, forced zero |