Digital panel meter instantaneous integration measurement SP-597Handling Company
U-Inix Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply | Mass/Dimensions | Alarm output selection | Alarm output display | Alarm output terminal | Alarm output method | Alarm output judgment | Alarm output reset | Alarm output mode | Alarm output preset value | Alarm Judgment output prohibition time | Measurement type | Measurement method | Display | Display plank | Instantaneous display accuracy | Instantaneous display range | Instantaneous display sampling time | Instantaneous display Measurement unit | Instantaneous display Moving average number of times | Instantaneous display Decimal display | Instantaneous display Auto zero time | Protection class | Operating temperature and humidity | Reset input (DISP1, DISP2) | Mode protect | Data backup | Scaling (converter) | Case material/color | EXT input |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SP-597 |
Available upon quote |
AC 85 ~ 264V 50/60Hz Approx. 22VA or less |
Approximately 515g |
Select from function stop, DISP1, DISP2 |
During each alarm output OUT1 ~ OUT4 LED lamp lights up |
Terminal block 11-12 (OUT1), terminal block 13-14 (OUT2) |
Photomos relay A contact output 4 stages |
Judgment output by comparing display value and preset value |
Alarm output is canceled when the front reset key is ON for 2 seconds or more (selected in mode No. P-02) and the terminal block reset input is ON for 50ms or more. |
Select from comparison, retention, and 1-shot output |
Set by preset value setting |
When the power is turned on or after a reset, the alarm output function is stopped within the set time. |
Instant/integral measurement (flow rate, speed, rotation, etc.) |
Periodic calculation method |
Upper row: 7 segment red LED 6 digits character height 14mm (DISP1) |
DISP1, DISP2 display can be turned on/off individually |
|
-9,999 ~ 99,999 |
Average display over 0.1 to 100.0 seconds (set arbitrarily) |
Set as per hour, minute, or second. |
Average the number of input pulses from 1 to 29 (set arbitrarily) |
Display can be selected from 1 to 4 digits after the decimal point |
After input stops, display is 0 (select from 10 steps from 0.5 to 180 seconds) |
IP66 equivalent |
-10 ~ 50℃ 30 ~ 80%RH (no condensation) |
Input from terminal block 7-6 (DISP1) and terminal block 8-6 (DISP2) |
It is possible to disable the mode setting value from being changed by key operation. |
Write each setting value and integrated value to FRAM |
Magnification per signal: Set arbitrarily from 1×10^-9 to 9,999 |
ABS resin glass filled gray |
Input from terminal block 9-6 Accepted when terminal block is ON for 50ms or more |