Digital panel meter Analog instantaneous total indicator SP-563AHandling Company
U-Inix Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Display | Totalization display lamp | Totalization display Decimal point display | Totalization display Synchronous pulse output | Totalization display reset | Totalization display Scaling (converter) | Totalization display Over display | Accumulated top display | Instantaneous indicator lamp | Instantaneous display Least significant digit display | Instantaneous display Decimal display | Instantaneous display scaling (converter) | Instantaneous display Over display | Instantaneous display Auto zero time | Measurement method | External input display switching | External input | External prohibited input | External hold input | Mode protection function | Hard low cut | Data backup | Soft low cut | Sensor input temperature characteristics | Sensor input precision linearity | Sensor input A5 type | Sensor input A4 type | Sensor input A3 type | Sensor input A2 type | Sensor supply power |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SP-563A |
Available upon quote |
Red LED 6 digits Character height: 14mm |
Lights up while displaying the integrated measurement value (switch to instantaneous display using the "Enter" key on the front panel) |
Display setting possible from 1 to 4 digits after the decimal point (fixed decimal point calculation) |
Integration display and synchronous output |
Front “reset” key/terminal block reset ON for 50ms or more |
Set the maximum input frequency and maximum integrated value per hour |
OV lamp blinks when display is over |
Displays the top 7 to 9 digits while the front “Up” key is ON (however, up to -999 to 999) |
Lights up while displaying the instantaneous measurement value (switch to integrated display using the "Enter" key on the front panel) |
Select from Real display, 0 fixed display, 0 or 5 display |
Display setting possible from 1 to 4 digits after the decimal point (fixed decimal point calculation) |
Set maximum input frequency and display value at maximum analog input |
When the display is over, the OV lamp/display value "999,999" flashes. |
0.1 ~ 99.9 (set arbitrarily) seconds after input stops |
Periodic calculation method (instantaneous measurement) |
When selected in the external input setting, switching between instantaneous display and integrated display when the input is turned on. |
Accepts NPN open collector output or contact output |
When selected in external input settings, sensor input is ignored while input is ON. |
When selected in the external input setting, the display is retained while the input is ON. |
Functions by operating the front “down” key (mode settings cannot be changed) |
Hardware ignores inputs below 0.5% of maximum input frequency (fixed) |
Write each mode setting value and integrated measurement value to FRAM |
Software ignores inputs between 1 and 29% of the maximum input frequency (set arbitrarily) |
±200ppm/℃ |
±0.2%F.S.±1digit (23℃) |
Analog voltage input: DC 0V ~ 10V Input resistance 220KΩ |
Analog voltage input: DC 0V ~ 5V input resistance 220KΩ |
Analog voltage input: DC 1V ~ 5V input resistance 220KΩ |
Analog current input: DC 4mA ~ 20mA input resistance 250Ω |
DC +24V (±10%) 100mA MAX (regulated) output |