Product
Digital panel meter analog display instantaneous totalizer SP5631Handling Company
U-Inix Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Measurement type | Measurement method | Display | Display switching | Display blank | Integral measurement display accuracy | Integrated measurement Displayable range | Total measurement decimal point position | Integral measurement synchronous pulse output | Integral measurement scaling | Total measurement over display | Totalization display lamp (D2) | Accumulated top display | Instant measurement display accuracy | Instant measurement Displayable range | Instant measurement Display sampling time | Instant measurement, lowest digit display | Instant measurement Decimal point position | Instant measurement low cut | Instant measurement scaling | Instant measurement Over display | Instantaneous indicator lamp (D1) | Sensor power supply | Sensor input method | Sensor input measurement range | Sensor input temperature characteristics | Sensor input Maximum allowable input | Sensor input maximum resolution | RST input method | RST input reset operation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SP5631 |
Available upon quote |
Instant measurement/integrated measurement |
A/D conversion method (input measurement interval: approx. 20ms) |
Red LED 6 digits Character height: approx. 21mm |
Instantaneous measurement, integrated measurement (switch with ENT key on the front) |
Hide measurement values |
±0.2%F.S.+1digit |
0 ~ 999,999 |
0 ~ 0.0000 |
Use alarm output OUT1 as synchronous pulse output |
Set the integrated value per hour at maximum analog input |
Overlamp (OV) lights up when the display range is exceeded. |
Lights up while displaying integrated measurement value |
While the front up key is ON, the upper 7th to 9th digits are displayed. |
±0.2%F.S.+1digit |
0 ~ 999,999 |
Averaged in 0.1 ~ 10 seconds |
Normal (0 ~ 9), 0 (fixed), 0 or 5 |
0 ~ 0.0000 |
Cuts 0.1 to 29.9% of analog input F.S. |
Set the display value at maximum analog input |
Overlamp (OV) lights up when the display range is exceeded. |
Lights up while displaying instantaneous measurement value |
DC 24V (±10%) 100mA |
A2: DC 4~20mA Input resistance: Approx. 250Ω |
Can measure up to 110% of full scale input |
±200ppm/℃ |
Current input: ±30mA |
Approximately 50,000 |
NPN open collector or no-voltage contact |
Reset the integrated measurement value and cancel the alarm output |