Digital panel meter standard totalizer CU-666Handling Company
U-Inix Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply | Mass/Dimensions | Alarm output display | Alarm output terminal | Alarm output method | Alarm output reset | Alarm output mode | Alarm output timing | Alarm output Accumulated synchronous pulse output | Alarm output comparison method | Alarm output preset value setting | Alarm output 1 shot time | Integral display accuracy | Integration display range | Integration display | Integration display switching | Totalization display offset | Totalization display Decimal point display | Totalization display reset | Totalization display Scaling (converter) | Totalization display Over display | External reset input | External hold selection input | Operating temperature and humidity | Mode protection function | Data backup | Sensor input response | Sensor input signal | Sensor supply power | Case material |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CU-666 |
Available upon quote |
AC 85~264V (50/60Hz) Approx. 20VA or less |
Approximately 400g |
When OUT1 is outputting an alarm, the OUT1 LED (red) lights up in sync. |
Each output from terminal block 9-6 (OUT1) and 10-6 (OUT2) (6 is common to GND) |
2 NPN open collector pulse outputs |
Turn on the front section “reset key” and terminal block reset input (4-3) for more than 50ms |
Select from comparison, hold, 1 shot, 1 shot return to 0, and synchronous output. |
Judgment output by comparing display value and preset value |
Output width: Select from 10 steps from 10ms to 2s |
Upper limit/lower limit (immediate) - Selection setting from integrated synchronous pulse output |
Can be set arbitrarily within the range of -99,999 to 999,999 by preset value setting |
Select from 10 levels from 10ms to 2s |
Scaling (converter) Error ±0 at 1 |
-99,999 ~ 999,999 |
6 digit LED character height: 14mm (red) |
When display 1, D1 LED (green) lights up, when display 2, D2 LED (green) lights up |
The display value after reset can be changed by setting the display offset value. |
Any selection is possible from 1 to 3 digits after the decimal point. |
Front section "Reset key" and terminal block reset input (reset display selected depending on mode) |
Set arbitrarily the magnification per signal from 1×10^-9 to 9999 |
3rd round stop (“999,999” or “-99,999” flashes on the third over) |
Turn on terminal block (4-3) for 50ms or more |
Select from prohibition, hold, lap count, and display switching |
0~50℃ 30~80%RH (no condensation) |
Functions by "down key" operation (mode setting cannot be changed) |
Write each mode setting value and integrated measurement value to FRAM |
LOW: 0.01Hz ~ 50Hz |
NPN open collector pulse input (MIN 10mA or more) or no-voltage contact |
DC +12V (±10%) 100mA |
Housing: ABS resin glass included |