All Categories
History
Response Rate
100.0%
Response Time
39.1hours
Product
Digital panel meter standard revolution/instantaneous meter SP-556Handling Company
U-Inix Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Alarm output method | Alarm output mode | Alarm output comparison method | Alarm output maximum rating | Alarm output judgment prohibition time | Measurement type | Measurement method | Instantaneous display accuracy | Instantaneous indicator | Instantaneous display range | Instant display blank | Instantaneous display sampling time | Instantaneous display Moving average | Instantaneous display Least significant digit | Instantaneous display Decimal point position | Instantaneous display unit time | Instant display reset | Instantaneous display scaling | Instantaneous display Over display | Instantaneous display Auto zero time | Power consumption | Rated power supply voltage | Reset input method | Mode protect | Data backup | Sensor input response | Sensor input signal | Sensor supply power | EXT input method | EXT input operation selection |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SP-556 |
Available upon quote |
NPN open collector (×2) |
Compare, hold, 1 shot |
Compare display value and preset value |
DC 30V 50mA |
Alarm output stops for 0 to 99 seconds when power is turned on or after reset |
Speed, rotation, instantaneous flow rate, differential speed, ratio, shot speed, passing time, cycle timer, stopwatch |
Periodic calculation method |
|
Red LED 5 digits Character height 14mm |
-9,999 ~ 99,999 |
Hide measurement values |
Averaged from 0.1 seconds to 99.9 seconds |
Average measurement for each input pulse from 1 to 19 times |
Usually 0 (fixed), 0 or 5 |
10^-1, 10^-2, 10^-3, None |
Every hour, every minute, every second |
Reset measurement using front reset key and terminal block RST input |
1×10^-9 ~ 9,999 (per pulse) |
“99,999” flashing or “-9,999” |
Display "0" 0.5 ~ 120 seconds after input stops |
20VA or less |
AC 100 ~ 240V (-15% / +10%) 120mA MAX 50 / 60Hz |
NPN open collector or no-voltage contact |
Prohibit changing mode settings |
Save each setting value to FRAM |
LOW: 0.01Hz ~ 50Hz |
NPN open collector or no-voltage contact |
DC +12V (±10%) 100mA |
NPN open collector or no-voltage contact |
Hold, peak hold, bottom hold, reverse rotation input |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
39.1hrs