Digital panel meter small instant meter SP-491Handling Company
U-Inix Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Alarm output display | Alarm output terminal | Alarm output comparison method | Alarm output method | Alarm output judgment | Alarm output reset | Alarm output mode | Alarm output judgment prohibition time | Alarm output one shot time | Alarm output preset value setting | Measurement type | Measurement method | Display (2-level display) | Instant measurement accuracy | Instant measurement display range | Instant measurement Display moving average | Instant measurement Display scaling method | Instant measurement Display sampling time | Instant measurement Least significant digit correction | Instant measurement Decimal point display | Instant measurement Low cut function | Power consumption | External EXT input | Operating power supply | Mode protection function | Data backup | Sensor input temperature characteristics | Sensor input Current input | Sensor input Voltage input | Warm up time |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SP-491 |
Available upon quote |
During each alarm output, OUT1, OUT2, OUT3, OUT4 LED (orange) lights up. |
Output from terminal blocks 10-11 (OUT1) and 12-11 (OUT2) (common to COM1) |
Can be selected from upper/lower limit (immediate)/lower limit (delayed) |
NPN open collector output 4 points |
Judgment output is made by comparing the displayed value and preset value. |
Reset by front “reset” key or EXT input |
Select from Compare, Hold, or 1 shot |
After turning on the power or resetting, the alarm output function is stopped during the 9-step judgment prohibition time (1 to 60 seconds) |
Selectable from 8 levels from 30ms to 2s |
Can be set arbitrarily by preset value setting mode |
Instant measurement (displays the input after scaling conversion) |
A/D conversion method |
Upper display: Red LED 4-digit display Character height: 7mm (zero suppression method) |
For full scale span analog input, |
-999 ~ 0 ~ 9,999 (displays the number of digits ignoring the decimal point) |
Average the set display sampling time from 1 to 9 times (can be set arbitrarily) |
A input display: Set the display value at maximum input (displays "0" at minimum input) |
Average display from 0.1 seconds to 10.0 seconds (can be set arbitrarily) |
Selectable from “Normal”, “0 fixed”, “0 or 5 display” |
Selectable from 0 to 3 digits after the decimal point (can be set individually for upper and lower digits) |
0 to 29% of maximum analog input (can be set arbitrarily) |
7VA or less |
Selectable from reset or hold |
DC 24V (±10%) |
Switching selection by mode protect setting |
Write each mode setting value to RRPROM |
±100ppm/℃ (0 ~ 50℃) |
A2 DC 4 ~ 20mA Input resistance approximately 250Ω |
A3 DC 1 ~ 5V Input resistance approximately 220kΩ |
30 minutes or more after power on |