Production line World's first (decompression chamber method) Hydrogen gas leak detector Hydrogen leak test system FER-H2-FER-H2
Production line World's first (decompression chamber method) Hydrogen gas leak detector Hydrogen leak test system FER-H2-A-Gas Japan Co., Ltd.

Production line World's first (decompression chamber method) Hydrogen gas leak detector Hydrogen leak test system FER-H2
A-Gas Japan Co., Ltd.

A-Gas Japan Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

103.8hours


About This Product

■Features

・Achieved expanded measurement range and high accuracy using a unique measurement method (decompression chamber method) ・Reduce equipment costs and running costs ・Propose measurement environment preparation

■Chamber unit supports up to 4 channels

- It is possible to reduce takt time and measure different types of workpieces. ・Chamber: We manufacture a chamber that matches the customer's workpiece to minimize the remaining volume and measure with high sensitivity *The chamber, seal jig, and clamp are created in a shape that matches the customer's workpiece each time, so a separate estimate will be required. Masu.

■Measurement/control unit

・Equipment can be operated with touch panel ・The operating status of the measurement circuit is displayed in real time, which is convenient for checking operation and troubleshooting. ・Detector: Capable of measuring 1 to 4 channels, each channel has a pass function and can operate on any channel, 16 patterns of measurement conditions can be set depending on differences in workpieces, etc. Equipped with automatic calibration function

■Sensor unit

- Up to 4 channels of sensor units can be installed in the measurement circuit. - Equipped with a spare sensor that will automatically switch if there is damage due to exposure to high concentration gas.

  • Product

    Production line World's first (decompression chamber method) Hydrogen gas leak detector Hydrogen leak test system FER-H2

Share this product


60+ people viewing

Last viewed: 58 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Production line World's first (decompression chamber method) Hydrogen gas leak detector Hydrogen leak test system FER-H2

Image Part Number Price (excluding tax) Power supply voltage Mass (kg) Test method Test gas Measuring range Test pressure Chamber unit size (mm) Channel
Production line World's first (decompression chamber method) Hydrogen gas leak detector Hydrogen leak test system FER-H2-Part Number-FER-H2

FER-H2

Available upon quote

AC90~110V AC200~240V Three phase 50/60Hz

700

Decompression chamber method

5% hydrogen + 95% nitrogen (gas concentration)

Decompression chamber method: 3.0×10-6Pa・m^3/s or more (Measurement conditions: chamber remaining volume 500ml)

Less than 5MPa

①W200×D200×H100, ②W600×D300×H200, ③W900×D400×H300

1~4ch

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Gas Sensors Products

Other products of A-Gas Japan Co., Ltd.