All Categories

History

Freon gas leak prevention Stationary type Freon gas leak detector Infrared type Freon gas leak detector-D4302
Freon gas leak prevention Stationary type Freon gas leak detector Infrared type Freon gas leak detector-D4306
Freon gas leak prevention Stationary type Freon gas leak detector Infrared type Freon gas leak detector-A-Gas Japan Co., Ltd.

Freon gas leak prevention Stationary type Freon gas leak detector Infrared type Freon gas leak detector
A-Gas Japan Co., Ltd.

A-Gas Japan Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

88.3hours


About This Product

■Features

・Compatible with new refrigerants R32 and R1234yf ・For line inspection of refrigeration and air conditioning equipment compatible with each refrigerant ・Two types of sensitivity can be set by switching between two circuits. ・No balance adjustment required/Complete auto zero - Stability and ease of maintenance of analog circuits ・For mass production lines with an emphasis on cost ・R600A and R290 gas are also supported with special models.

■Features

・The “D43” series uses an IR sensor that utilizes the principle of infrared absorption of gas, and was developed with the aim of providing low-cost, easy-to-use equipment. ・It is now possible to maintain stable sensitivity that is less susceptible to background effects. -Uses a lightweight PEN type probe suitable for quick pass/fail judgments on mass production lines, reducing the burden on workers and increasing their ability to concentrate on inspection work. ・Completely auto-zero eliminates the need for operations such as balance adjustment. - Stable sensitivity can be maintained for a long period of time, freeing the operator from troublesome fine adjustments. -Using a universal power supply eliminates the effects of power supply voltage fluctuations. ・Adoption of small and lightweight PEN probe ・Flexible suction tube that is easy to replace ・When the suction pipe is removed, the filter can be seen directly, making it easy to determine whether it is dirty or whether it needs to be replaced. ・The first filter uses acetate to reduce erroneous reactions due to the influence of water vapor. ・Second filter (sintered metal) accurately blocks the cause of sensor contamination

  • Product

    Freon gas leak prevention Stationary type Freon gas leak detector Infrared type Freon gas leak detector

Share this product


100+ people viewing

Last viewed: 12 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

2 Models of Freon gas leak prevention Stationary type Freon gas leak detector Infrared type Freon gas leak detector

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power supply Weight/dimensions Alarm point Flow rate adjustment (ml/min.) Standard probe Highest sensitivity Sensitivity switching Response speed Target gas type Suction method Leak display Zero adjustment
Freon gas leak prevention Stationary type Freon gas leak detector Infrared type Freon gas leak detector-Part Number-D4302

D4302

Available upon quote

AC100 ~ 240V 50/60Hz 100VA or less

Body: approx. 7kg 260 (W) × 380 (D) × 160 (H) mm *Including rubber feet, probe: 100mm × 18mmΦ L=200mm with suction tube 75g

Meter pointer position 3 ~ 10 arbitrary points can be set

0 ~ 300 Initial setting 200

Flexible suction tube L=200mm, probe tube Φ4×1mm L=2m *Optional length available for each

5×10^-6ml/sec

L (10^-4) M (10^-5) H (10^-6) 3 stages plus AB circuit Sensitivity adjustment VR (linear)

Within 1 second *When using L=200mm suction tube L=2m probe tube

R32,R410A,R22,R134A,R1234yf,R404A,R407C,SF6 etc.

DC drive (DC - AC conversion) diaphragm pump

Analog meter and speaker alarm sound

Fully automatic/no adjustment

Freon gas leak prevention Stationary type Freon gas leak detector Infrared type Freon gas leak detector-Part Number-D4306

D4306

Available upon quote

AC100 ~ 240V 50/60Hz 100VA or less

Body: approx. 7kg 260 (W) × 380 (D) × 160 (H) mm *Including rubber feet, probe: 100mm × 18mmΦ L=200mm with suction tube 75g

Meter pointer position 3 ~ 10 arbitrary points can be set

0 ~ 300 Initial setting 200

Flexible suction tube L=200mm, probe tube Φ4×1mm L=2m *Optional length available for each

5×10^-6ml/sec

L (10^-4) M (10^-5) H (10^-6) 3 stages plus AB circuit Sensitivity adjustment VR (linear)

Within 1 second *When using L=200mm suction tube L=2m probe tube

R600A,R290

DC drive (DC - AC conversion) diaphragm pump

Analog meter and speaker alarm sound

Fully automatic/no adjustment

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Gas Sensors Products

Other products of A-Gas Japan Co., Ltd.

Reviews shown here are reviews of companies.


View more products of A-Gas Japan Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

88.3hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree