All Categories

History

Zgaiard X series (inverter)-ZV08AX-R
Zgaiard X series (inverter)-ZV11AX-R
Zgaiard X series (inverter)-ZV15AX-R
Zgaiard X series (inverter)-ZV22AX-R
Zgaiard X series (inverter)-ZV37AX-R
Zgaiard X series (inverter)-ZV55AX-R
Zgaiard X series (inverter)-Nakajima Koki Co., Ltd.

Zgaiard X series (inverter)
Nakajima Koki Co., Ltd.

Nakajima Koki Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

48.3hours


About This Product

■The ultimate precision pursuit

・By maximizing the unique compression mechanism "Z Screw", we have achieved a maximum of 10% increase in discharged air volume. ・Uses a motor that complies with Top Runner regulations, achieving both high efficiency and energy savings. ・In addition to the roll system, an instant start system is adopted. Common specifications for inverter type and basic type

■The largest amount of air discharged in its class

・Achieving the ultimate precision of the compression mechanism by leveraging the know-how of a machine tool manufacturer ・Optimization of the ideal compression shape (Z screw) using the latest processing technology and analysis ・Increase the amount of discharged air by up to 10% compared to the conventional model

■Global warming countermeasure machine

・By reviewing the intake and exhaust cooling circuits, it is possible to operate without abnormal shutdowns even at ambient temperatures of 50 degrees Celsius. ・Uses a high-efficiency, high-inlet air temperature dryer ・Increased air cooling operation starts when the discharge temperature is 95℃ or higher. *The lifespan of electrical components will be shorter than normal in environments where the ambient temperature exceeds 40℃.

■Improved maintainability

Reduce maintenance parts by unitizing lubricating oil circuit and control circuit

■Top runner system compatible machine

At Mitsui Seiki, we affix a "PREMIUM" sticker to both the basic type and inverter type to clearly indicate that all of our models comply with the "Top Runner Regulations." Inverter type specifications

■Instant start system adopted

・Added instant start system in addition to AUCS (auto unloader control system) ・Improved followability of terminal pressure and greatly reduced idle time with automatic start/stop operation, number control operation, etc. *: The value in parentheses is the discharge air amount for 0.50MPa specification (optional). *Values ​​are based on the conditions of ambient temperature 30℃, humidity 75%, and rated discharge pressure.

  • Product

    Zgaiard X series (inverter)

Share this product


510+ people viewing

Last viewed: 2 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Zgaiard X series (inverter)

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Noise level dB・(A) Drive method Power supply voltage (50/60Hz,V) Radio frequency (Hz) Motor type Motor output (kW) Mass (dry) kg Lubricating oil filling amount (L) Width x depth x height [dryerless] mm Capacity control method Starting method Suction conditions Discharge air volume (m3/min) Discharge air diameter (R) Discharge pressure (adjustment range) MPa Cooling method Fan motor output (kW) Dryer power consumption (kW) Dryer outlet air dew point (℃) Dryer refrigerant filling amount (g) Dryer refrigerant used
Zgaiard X series (inverter)-Part Number-ZV08AX-R

ZV08AX-R

Available upon quote

52

Coupling direct drive

Three phase 200/200・220

50/60 shared

Totally enclosed external fan three-phase induction motor (IE3 motor)

7.5

430

7

905 × 705 × 1,400

Constant pressure control by inverter (rotation speed control)

Inverter start

Atmospheric pressure (2~40℃)

1.21

3/4

0.7 [0.60~0.93]

Air cooling

0.4 (inverter control)

0.352 / 0.408・0.432

10 (under pressure) *

240

R-407C

Zgaiard X series (inverter)-Part Number-ZV11AX-R

ZV11AX-R

Available upon quote

53

Coupling direct drive

Three phase 200/200・220

50/60 shared

Totally enclosed external fan three-phase induction motor (IE3 motor)

11

480

7

1,050 × 750 × 1,400

Constant pressure control by inverter (rotation speed control)

Inverter start

Atmospheric pressure (2~40℃)

1.86

3/4

0.7 [0.60~0.93]

Air cooling

0.4 (inverter control)

0.360 / 0.440・0.460

10 (under pressure) *

260

R-407C

Zgaiard X series (inverter)-Part Number-ZV15AX-R

ZV15AX-R

Available upon quote

54

Coupling direct drive

Three phase 200/200・220

50/60 shared

Totally enclosed external fan three-phase induction motor (IE3 motor)

15

560

9

1,050 × 750 × 1,400

Constant pressure control by inverter (rotation speed control)

Inverter start

Atmospheric pressure (2~40℃)

2.64

1

0.7 [0.53~0.93]

Air cooling

0.9 (inverter control)

0.528 / 0.612・0.640

10 (under pressure) *

300

R-407C

Zgaiard X series (inverter)-Part Number-ZV22AX-R

ZV22AX-R

Available upon quote

54

Coupling direct drive

Three phase 200/200・220

50/60 shared

Totally enclosed external sector permanent magnet rotor variable speed synchronous motor (IPM motor)

Twenty two

590

15

1,280 [1,160] × 750 × 1,490

Constant pressure control by inverter (rotation speed control)

Inverter start

Atmospheric pressure (2~40℃)

4.2 (4.5) *

1

0.7 [0.53~0.93]

Air cooling

0.75 (inverter control)

1.1/1.3

10 (under pressure) *

650

R-410A

Zgaiard X series (inverter)-Part Number-ZV37AX-R

ZV37AX-R

Available upon quote

58

Coupling direct drive

Three phase 200/200・220

50/60 shared

Totally enclosed external sector permanent magnet rotor variable speed synchronous motor (IPM motor)

37

830

20

1,750 [1,550] × 750 × 1,550

Constant pressure control by inverter (rotation speed control)

Inverter start

Atmospheric pressure (2~40℃)

7.0 (7.4 ) *

1・1/2

0.7 [0.53~0.93]

Air cooling

2.2 (Inverter control)

1.4/1.7

10 (under pressure) *

1,050

R-410A

Zgaiard X series (inverter)-Part Number-ZV55AX-R

ZV55AX-R

Available upon quote

64

Coupling direct drive

Three phase 200/200・220

50/60 shared

Totally enclosed external sector permanent magnet rotor variable speed synchronous motor (IPM motor)

55

1,400

38

2,008 × 1,183 × 1,750

Constant pressure control by inverter (rotation speed control)

Inverter start

Atmospheric pressure (2~40℃)

10.2 (11.5) *

2

0.7 [0.53 ~ 0.93 ] (0.5) *

Air cooling

1.5 (inverter control)

1.8/2.2

10 (under pressure) *

1,050

R-410A

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Compressors Products

Other products of Nakajima Koki Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Nakajima Koki Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

48.3hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree