Wet UV oxidation total organic carbon analyzer QbD1200+-QbD1200+
Wet UV oxidation total organic carbon analyzer QbD1200+-Nittoseiko Analytech Co., Ltd

Wet UV oxidation total organic carbon analyzer QbD1200+
Nittoseiko Analytech Co., Ltd


About This Product

Since the QbD1200 measures IC (inorganic carbon) and TOC sequentially with a single sample injection, measurement errors caused by IC measurements can be minimized. Therefore, we have achieved high sensitivity on the ppb order. In addition, running costs are low because it is a wet oxidation method that does not use expensive platinum catalysts. Furthermore, we comply with international standards such as Japanese and American analysis method validation required for pharmaceutical water. FDA 21 CFR part 11, ICH Q2B, USP<643>, EP<2.2.44>, JP16<2.59>, IP, CP, KP, US EPA 5310c Features ■Supports data integrity as a standalone product There is no need for a computer or external software, and the built-in software of the device is equipped with functions necessary for data integrity, such as ``audit trail recording and read management'', ``login user management'', and ``data backup and restoration''. I am. In addition, we support pharmaceutical companies by providing auxiliary functions to more efficiently implement GMP operations, such as validation and maintenance planning and history management functions. ■Highly sensitive analysis and stable measurement possible By using high-sensitivity NDIR and clean vials, measurements on the order of ppb can be performed stably. Additionally, we can supply reagents such as oxidizing agents and standard solutions that we have independently adjusted and managed, allowing for stable measurements. ■Using a large color touch panel Pursuing high operability and simplicity with a large 10.4-inch color touch panel, all operating steps such as initial settings and measurements are greatly simplified, and stand-alone operation is possible without the need for a PC. ■Reliability of measured values We offer an auto sampler that can measure up to 64 samples. In addition, we use cleanly cleaned glass vials to minimize the possibility of measurement errors due to contamination. ■Automatic creation of calibration curve After automatic dilution using one standard reagent, a 5-point calibration curve is automatically created. Furthermore, the custom calibration function allows calibration using any standard reagent concentration prepared as desired. Also compatible with clean water testing methods.

  • Product

    Wet UV oxidation total organic carbon analyzer QbD1200+

Share this product


50+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Wet UV oxidation total organic carbon analyzer QbD1200+

Product Image Part Number Price (excluding tax) Detection method Dimensions/mass Display Gas used Measurement time Measuring range Number of samples Oxidation method Power supply
Wet UV oxidation total organic carbon analyzer QbD1200+-Part Number-QbD1200+

QbD1200+

Available upon quote NDIR detection Body: Approx. 320 (W) x 507 (D) x 410 (H) mm Approx. 10kg
Sample changer: Approx. 366 (W) x 537 (D) x 457 (H) mm Approx. 21kg
10.4 inch high definition color touch screen CO2 free gas (N2 purity 99.99% or higher or air, dehumidification required) 6~10 minutes *Depends on sample amount and measurement conditions. 1.2ppb~100ppm (detection limit 0.4ppb) Up to 64 40mL glass vials Wet UV oxidation method Main unit: AC100~240V approximately 600VA
Sample changer: AC100~240V approximately 200VA