Product
Digital controller SR90 seriesHandling Company
SHIMADENCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply | Weight | Adjustment | Display accuracy | Display update cycle | Power consumption | External dimensions | Reference junction compensation accuracy | Ambient temperature | Output type (current) | Output type (voltage) | Output type (load current) | Output type (load resistance) | Output type (contact) | Output type (SSR drive voltage) | Input type | Operating environment conditions | Options (communication function) | Options (control output 2) | Options (external control input/output) | Option (Heater disconnection) | Options (event output) | Options (analog output) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SR91 |
Available upon quote |
100~240V±10% AC 50/60Hz |
Approximately 170g |
Expert PID with auto-tuning function |
±0.3%FS+1digit |
0.25 seconds |
100~240V AC 11VA or less |
H48×W48×D111mm (depth inside panel 100mm) |
±1℃ |
18~28℃ |
4~20mA DC |
0~10V DC |
2mA or less |
600Ω or less |
1a 240V AC 2A (resistive load) |
12V±1.5V DC 30mA or less |
Multi input |
-10~50℃ 90%RH or less (no condensation) |
RS-485, RS-232 |
Contacts, current, SSR drive voltage, voltage |
1 point |
1 point 30A, 50A CT included (remote setting and heater disconnection are exclusive selections) |
2 points 1a 240V AC 1A (resistive load) |
1 point 0~10mV, 4~20mA, 0~10V |
|
SR92 |
Available upon quote |
100~240V±10% AC 50/60Hz |
Approximately 280g |
Expert PID with auto-tuning function |
±0.3%FS+1digit |
0.25 seconds |
100~240V AC 15VA or less |
H72×W72×D111mm (depth inside panel 100mm) |
±1℃ |
18~28℃ |
4~20mA DC |
0~10V DC |
2mA or less |
600Ω or less |
1a 240V AC 2A (resistive load) |
12V±1.5V DC 30mA or less |
Multi input |
-10~50℃ 90%RH or less (no condensation) |
RS-485, RS-232 |
Contacts, current, SSR drive voltage, voltage |
1 point |
1 point 30A, 50A CT included (remote setting and heater disconnection are exclusive selections) |
2 points 1a 240V AC 1A (resistive load) |
1 point 0~10mV, 4~20mA, 0~10V |
|
SR93 |
Available upon quote |
100~240V±10% AC 50/60Hz |
Approximately 330g |
Expert PID with auto-tuning function |
±0.3%FS+1digit |
0.25 seconds |
100~240V AC 15VA or less |
H96×W96×D111mm (depth inside panel 100mm) |
±1℃ |
18~28℃ |
4~20mA DC |
0~10V DC |
2mA or less |
600Ω or less |
1a 240V AC 2A (resistive load) |
12V±1.5V DC 30mA or less |
Multi input |
-10~50℃ 90%RH or less (no condensation) |
RS-485, RS-232 |
Contacts, current, SSR drive voltage, voltage |
1 point |
1 point 30A, 50A CT included (remote setting and heater disconnection are exclusive selections) |
2 points 1a 240V AC 1A (resistive load) |
1 point 0~10mV, 4~20mA, 0~10V |
|
SR94 |
Available upon quote |
100~240V±10% AC 50/60Hz |
Approximately 240g |
Expert PID with auto-tuning function |
±0.3%FS+1digit |
0.25 seconds |
100~240V AC 15VA or less |
H96×W48×D111mm (depth inside panel 100mm) |
±1℃ |
18~28℃ |
4~20mA DC |
0~10V DC |
2mA or less |
600Ω or less |
1a 240V AC 2A (resistive load) |
12V±1.5V DC 30mA or less |
Multi input |
-10~50℃ 90%RH or less (no condensation) |
RS-485, RS-232 |
Contacts, current, SSR drive voltage, voltage |
1 point |
1 point 30A, 50A CT included (remote setting and heater disconnection are exclusive selections) |
2 points 1a 240V AC 1A (resistive load) |
1 point 0~10mV, 4~20mA, 0~10V |
Click on the part number for more information about each product