All Categories
History
Product
Leak detector for Freon Accuprobe UVHandling Company
ASADA CO., LTD.Categories
Image | Part Number | Price (excluding tax) | Power supply | Mass | Temperature range | Standard accessories | Detection method | Sensitivity | Compatible refrigerant | Size | Probe length | Sensor life | Code No. | Gas introduction method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Accuprobe UV |
Available upon quote |
100V or 4 AA alkaline batteries (life span: approx. 4.5 hours) |
480g (including battery) |
Operating temperature: –4~52℃ |
100V AC power adapter, 4 AA alkaline batteries, sensor, spare filter, leak check bottle, case |
Heat semiconductor sensor type |
R22: 0.9gg/year, R134a: 1.7g/year, R410A: 1.7g/year |
Freon such as R410A, R407C, R404A, R507A, R134a, R12, R22, R500, R502, HFO1234yf, HFO1234ze, HFO1233zd, R32, R245fa |
L: 65 x W: 68 x H: 265mm |
430mm |
300 hours |
Y69338 |
Gas suction method |