Adjustment
Ambient temperature
Display accuracy
Display update cycle
External dimensions
Input type
Operating environment conditions
Options (CT input)
Options (analog output)
Options (communication function)
Options (control output 2)
Options (event output)
Options (external control input/output)
Output type (SSR drive voltage)
Output type (contact)
Output type (current)
Output type (load current)
Output type (load resistance)
Output type (voltage)
Power consumption
Power supply
Reference junction compensation accuracy
Weight
Part Number
SRS13AProduct
Digital controller SRS10A seriesHandling Company
SHIMADENCategories
Image | Price (excluding tax) | Adjustment | Ambient temperature | Display accuracy | Display update cycle | External dimensions | Input type | Operating environment conditions | Options (CT input) | Options (analog output) | Options (communication function) | Options (control output 2) | Options (event output) | Options (external control input/output) | Output type (SSR drive voltage) | Output type (contact) | Output type (current) | Output type (load current) | Output type (load resistance) | Output type (voltage) | Power consumption | Power supply | Reference junction compensation accuracy | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Expert PID with auto-tuning function | 5~45℃ | ±0.25%FS+1digit | 0.25 seconds | H96×W96×D69mm (depth inside panel 65mm) | Multi input Thermocouple: 14 types RTD: 2 types Voltage (mV): 6 types Voltage input (V): 6 types Current input is used by attaching a shunt resistor (sold separately) to voltage input. | -10~50℃ 90%RH or less (no condensation) | Requires 2 CTs (30A, 50A) sold separately | 1 point 0~10mV, 4~20mA, 0~10V | RS-485 | Contact, current, SSR drive voltage, voltage (exclusive selection for extended event, extended external control input, and control output 2) | Maximum 3 points 240V AC 2A (resistive load) | Maximum 4 input points | 12V±1.5V DC 30mA or less | 1a 240V AC 2A (resistive load) | 4~20mA DC | 2mA or less | 600Ω or less | 0~10V DC | 100~240V AC 14VA or less | 100~240V±10% AC 50/60Hz | ±2℃ | Approximately 220g |