All Categories

History

Single-phase power regulator (thyristor unit SCR) THV-10 (20A, 30A, 45A, 60A, 80A, 100A)-RKC INSTRUMENT

Price (excluding tax)

Estimate Required


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Absolute humidity

Alarm output

Applicable load phase control

Base up setting (output bias)

Control method

Control power supply voltage

Cooling method

Gradient setting

Heater burnout alarm, current limiter function, etc.

Input sampling period

Input signal

Input/output plug side connector included

Insulation resistance

Insulation voltage

Leakage current when output is OFF

Load power supply voltage

Manual settings

Minimum load current

Output limiter (lower limit)

Output limiter (upper limit)

Output limiter time at startup

Output voltage range

Permissible ambient humidity

Permissible ambient temperature

Power consumption

Power frequency

Rated current

Startup output limiter (upper limit)

Transmission output or communication function

Zero cross control

See all 10 models in list
  • Part Number

    THV-10PZ020-5*HNN-N

Share this product


580+ people viewing

Last viewed: 4 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

Single-phase power regulator (thyristor unit SCR) THV-10 (20A, 30A, 45A, 60A, 80A, 100A) THV-10PZ020-5*HNN-N's performance table

Image Price (excluding tax) Absolute humidity Alarm output Applicable load phase control Base up setting (output bias) Control method Control power supply voltage Cooling method Gradient setting Heater burnout alarm, current limiter function, etc. Input sampling period Input signal Input/output plug side connector included Insulation resistance Insulation voltage Leakage current when output is OFF Load power supply voltage Manual settings Minimum load current Output limiter (lower limit) Output limiter (upper limit) Output limiter time at startup Output voltage range Permissible ambient humidity Permissible ambient temperature Power consumption Power frequency Rated current Startup output limiter (upper limit) Transmission output or communication function Zero cross control
Single-phase power regulator (thyristor unit SCR) THV-10 (20A, 30A, 45A, 60A, 80A, 100A)-Part Number-THV-10PZ020-5*HNN-N Available upon quote MAX.W.C 29g/m3 dry air at 101.3kPa No alarm output Resistive load, transformer primary side control (magnetic flux density approximately 1.25T or less) -9.9~100.0% (front key) Phase control/zero cross control method (Factory: Phase control) AC85~264V (including power supply voltage fluctuation) Rating: AC100~240V Natural cooling 0.00~2.00 (front key) 0.0~100.0% [External setting device (volume)] Heater burnout alarm, current limiter function, constant current control function, transformer primary side control protection function, power proportional control included 10ms when power frequency is 50Hz, 8.33ms when power frequency is 60Hz DC0~10V None Between main circuit terminal, power supply terminal and heatsink: 20MΩ or more, DC500V Between main circuit terminal, heatsink and input terminal: 20MΩ or more, DC500V Between power terminal and input terminal: 20MΩ or more, DC500V Between main circuit terminal and heatsink: AC2,500V, 1 minute Between power terminal and heatsink: AC2,500V, 1 minute Between main circuit terminal and input terminal: AC2,500V, 1 minute Between power terminal and input terminal: AC2,300V, 1 minute Approximately AC27mA rms or less (Load voltage 200V rms 60Hz Ta=25℃) AC85~264V (including power supply voltage fluctuation) Rating: AC100~240V 0.0~100.0% (front key) 0.0~100.0% [External setting device (volume)] 0.6A (at 98% output of rated voltage) 0.0~100.0% (front key) 0.0~100.0% (front key) 0~600 seconds (front key) 0~98% of load power supply voltage (Excluding voltage drop due to fuse) 5~95%RH (no condensation) -15~+55℃ (guaranteed operation range) 6VA or less (at AC100V) Inrush current 5.6A or less 8VA or less (at AC240V) Inrush current 13.3A or less 50/60Hz shared (automatic detection) Frequency fluctuation: Load power supply voltage 50Hz±1Hz, 60Hz±1.2Hz, control power supply voltage 50Hz±2Hz, 60Hz±2Hz AC20A 0.0~100.0% (front key) No function Resistive load

There are 10 models for this product.

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Thyristors Products

Other products of RKC INSTRUMENT

Reviews shown here are reviews of companies.


View more products of RKC INSTRUMENT

About Company Handling This Product

Company Overview

RKC Instrument has been continually growing for over half a century and strives to be a solution provider of m...

See More

  • Japan

Category of this product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.