All Categories
History
Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Absolute humidity
Alarm output
Applicable load phase control
Base up setting (output bias)
Control method
Control power supply voltage
Cooling method
Gradient setting
Heater burnout alarm, current limiter function, etc.
Input sampling period
Input signal
Input/output plug side connector included
Insulation resistance
Insulation voltage
Leakage current when output is OFF
Load power supply voltage
Manual settings
Minimum load current
Output limiter (lower limit)
Output limiter (upper limit)
Output limiter time at startup
Output voltage range
Permissible ambient humidity
Permissible ambient temperature
Power consumption
Power frequency
Rated current
Startup output limiter (upper limit)
Transmission output or communication function
Zero cross control
Part Number
THV-10PZ020-5*NNB-NHandling Company
RKC INSTRUMENTCategories
Image | Price (excluding tax) | Absolute humidity | Alarm output | Applicable load phase control | Base up setting (output bias) | Control method | Control power supply voltage | Cooling method | Gradient setting | Heater burnout alarm, current limiter function, etc. | Input sampling period | Input signal | Input/output plug side connector included | Insulation resistance | Insulation voltage | Leakage current when output is OFF | Load power supply voltage | Manual settings | Minimum load current | Output limiter (lower limit) | Output limiter (upper limit) | Output limiter time at startup | Output voltage range | Permissible ambient humidity | Permissible ambient temperature | Power consumption | Power frequency | Rated current | Startup output limiter (upper limit) | Transmission output or communication function | Zero cross control |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | MAX.W.C 29g/m3 dry air at 101.3kPa | No alarm output | Resistive load, transformer primary side control (magnetic flux density approximately 1.25T or less) | -9.9~100.0% (front key) | Phase control/zero cross control method (Factory: Phase control) | AC85~264V (including power supply voltage fluctuation) Rating: AC100~240V | Natural cooling | 0.00~2.00 (front key) 0.0~100.0% [External setting device (volume)] | No function | 10ms when power frequency is 50Hz, 8.33ms when power frequency is 60Hz | DC0~10V | None | Between main circuit terminal, power supply terminal and heatsink: 20MΩ or more, DC500V Between main circuit terminal, heatsink and input terminal: 20MΩ or more, DC500V Between power terminal and input terminal: 20MΩ or more, DC500V | Between main circuit terminal and heatsink: AC2,500V, 1 minute Between power terminal and heatsink: AC2,500V, 1 minute Between main circuit terminal and input terminal: AC2,500V, 1 minute Between power terminal and input terminal: AC2,300V, 1 minute | Approximately AC27mA rms or less (Load voltage 200V rms 60Hz Ta=25℃) | AC85~264V (including power supply voltage fluctuation) Rating: AC100~240V | 0.0~100.0% (front key) 0.0~100.0% [External setting device (volume)] | 0.6A (at 98% output of rated voltage) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0~600 seconds (front key) | 0~98% of load power supply voltage (Excluding voltage drop due to fuse) | 5~95%RH (no condensation) | -15~+55℃ (guaranteed operation range) | 6VA or less (at AC100V) Inrush current 5.6A or less 8VA or less (at AC240V) Inrush current 13.3A or less | 50/60Hz shared (automatic detection) Frequency fluctuation: Load power supply voltage 50Hz±1Hz, 60Hz±1.2Hz, control power supply voltage 50Hz±2Hz, 60Hz±2Hz | AC20A | 0.0~100.0% (front key) | Communication (RS-485) [RKC standard communication] *Communication plug side connector included | Resistive load |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.