All Categories
History
Price (excluding tax)
■Optical fiber type composite temperature sensor - Can be used to adhere to all types of surfaces, including non-homogeneous materials such as concrete and composites ・Measurement range: -20℃~80℃ - Aramid or armored cables for harsh environments ・Ideal for compensating strain sensor FS62CSS ・To ensure long-term durability, we recommend using aluminum foil ABM75 with soft putty or soft putty AK22.
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Bending radius of sensor part
External dimensions
FBG reflection wavelength
Fiber type
Hand width (FWHM), reflectance, sidelobe suppression
Input/output cable bending radius
Input/output cable length
Input/output cable type
Input/output connector
Installation method
Main material
Maximum calibration error
Measuring range
Operating humidity
Optical fiber cladding diameter/covering diameter
Resolution
Sensitivity
Storage humidity
Storage temperature
Temperature correction factor
Weight
Protection class
Part Number
FS63CTSHandling Company
Hottinger Brüel & KjærCategories
Image | Price (excluding tax) | Bending radius of sensor part | External dimensions | FBG reflection wavelength | Fiber type | Hand width (FWHM), reflectance, sidelobe suppression | Input/output cable bending radius | Input/output cable length | Input/output cable type | Input/output connector | Installation method | Main material | Maximum calibration error | Measuring range | Operating humidity | Optical fiber cladding diameter/covering diameter | Resolution | Sensitivity | Storage humidity | Storage temperature | Temperature correction factor | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | Cannot be bent | 130±0.5×20±0.5×6.5±0.5mm | 1,500~1,600nm (±0.5) | SMF-28 compatible | ≤0.3nm, 21±4%, >10dB | >30mm (When tested by winding the cable around a mandrel (cylindrical reel with a radius of 30mm), the induction loss during one revolution is less than 0.05dB) | 0.5~20m | Φ3mm aramid cable (Hytrel, Kevlar®, LSZH) or Φ3mm armored (Hytrel, stainless steel spiral, Kevlar®, stainless mesh, LDPE) | FC/APC, SC/APC, NC (no connector) | Adhesive (HBK FiberSensing recommends using a two-part epoxy adhesive such as 3M DP490 cold cure adhesive) | Stainless steel, CFRP (carbon fiber reinforced plastic), Ormocer® (the entire sensor configuration including the cable is RoHS, REACH, Conflict Minerals and Fire Propagation Directive compliant) | ±0.5°C (To achieve the absolute measurements listed in this data sheet, use a data logger with an accuracy of ±2 pm or better. Typical traceability uncertainty is ±0.7) | -20~+80℃ (Aramid cable's mechanical properties change above 70℃. Sensor operation and measurement values are not affected by this change) | <95% | 125/195μm | 0.02℃ (Resolution 0.5pm in wavelength measurement is the value for interrogator FS22SI) | 30pm/℃ (This is the value for FBG with a wavelength of 1,550nm.It can usually be approximated by a linear function, and corresponds to its first-order coefficient.) | <95% | -20~+80℃ | 20 (μm/m) /℃ (Temperature correction factor (TCF) is the apparent induced strain caused by a temperature change of 1℃. Temperature compensation of strain sensors uses this value.) | Φ3mm aramid: 47, Φ3mm armor: 97 (Weight when cable length is 2m and there are no connectors at both ends) |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.