All Categories

History

Basic/IEPE ISO 200kS/s module GN815/GN816-Hottinger Brüel & Kjær

Price (excluding tax)

Estimate Required


Model Description


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

ADC resolution

Analog channel

Analog input section connector

Analog input section input coupling-1

Analog input section input coupling-2

Analog input section input coupling-3

Analog input section input coupling-4

Analog input section input impedance

Antialias filter

Common Mode Rejection (CMR)

Common mode Maximum common mode voltage

Common mode range

Digital event/timer/counter

IEPE sensor input range

Input format

Input overload protection Maximum non-destructive voltage

Input overload protection Overload recovery time

Insulation

Maximum sampling rate per channel

Memory capacity per card

Passive voltage/current probe

Real-time cycle-based calculation function

Sensor

Slot width

TEDS

Voltage (all filters used) DC offset error

Voltage (all filters used) Offset error drift

Voltage (all filters used) RMS noise

Voltage (with all filters) DC gain error

Voltage (with all filters) Gain error drift

See all 2 models in list
  • Part Number

    GN816

Share this product


200+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

Basic/IEPE ISO 200kS/s module GN815/GN816 GN816's performance table

Image Price (excluding tax) ADC resolution () Analog channel () Analog input section connector () Analog input section input coupling-1 () Analog input section input coupling-2 () Analog input section input coupling-3 () Analog input section input coupling-4 () Analog input section input impedance () Antialias filter () Common Mode Rejection (CMR) () Common mode Maximum common mode voltage () Common mode range () Digital event/timer/counter () IEPE sensor input range () Input format () Input overload protection Maximum non-destructive voltage () Input overload protection Overload recovery time () Insulation () Maximum sampling rate per channel () Memory capacity per card () Passive voltage/current probe () Real-time cycle-based calculation function () Sensor () Slot width () TEDS () Voltage (all filters used) DC offset error () Voltage (all filters used) Offset error drift () Voltage (all filters used) RMS noise () Voltage (with all filters) DC gain error () Voltage (with all filters) Gain error drift ()
Basic/IEPE ISO 200kS/s module GN815/GN816-Part Number-GN816 Available upon quote 18bit 8 Insulated metal bnc Coupling mode: AC, DC, GND AC coupling frequency (1MΩ impedance): 1.6Hz±10%;-3dB Range (1MΩ impedance): ±10mV, ±20mV, ±50mV, ±0.1V, ±0.2V, ±0.5V, ±1V, ±2V, ±5V, ±10V, ±20V, ±50V Offset: ±50% at 1,000 steps (0.1%), offset fixed at 0% on ±50V range 1MΩ impedance ≤±1V range: ±1%//58pF, >±1V range: ±10%, all other ranges: 66pF±10% Fixed bandwidth analog AA filter combined with sampling rate tracking digital AA filter >60dB @80Hz (typical 80dB) 33V RMS ±2V or more 16 digital events and 2 timer/counter channels ±10mV, ±20mV, ±50mV, ±0.1V, ±0.2V, ±0.5V, ±1V, ±2V, ±5V, ±10V, ±20V Analog, isolated, unbalanced differential ±70V DC Recovers to 0.1% accuracy within 5μs after 200% overload Channel-to-channel and channel-to-chassis 200kS/s 200MB Passive, single-ended voltage probe 32; Cycle and timer-based calculations, with trigger function based on calculation results IEPE 1 Class 1, old PE sensor 0.01% of full scale ±35pV ± (45ppm+5pV) /°C (± (25ppm+3pV) /°F) 0.015% of full scale ±20pV (50Ω termination) 0.035% of reading ±35pV ±25ppm/°C (±14ppm/°F)

There are 2 models for this product.

Other products of Hottinger Brüel & Kjær

Reviews shown here are reviews of companies.


View more products of Hottinger Brüel & Kjær

About Company Handling This Product

Company Overview

HBK, formerly named HBM, is a global ISO9001 and ISO14001-certified company founded in 1950. It is known for p...

See More

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree