All Categories
History
Price (excluding tax)
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Allowable temperature range
Control volume (approximate)
Effect of power supply (with a change of 15V to 30V)
Input characteristics Accuracy class
Input characteristics Dynamic pressure Allowable pressure
Input characteristics Dynamic pressure Allowable vibration amplitude
Input characteristics Initial value
Input characteristics Limit pressure at standard temperature
Input characteristics Operating range at standard temperature
Input characteristics Pressure type
Input characteristics Test pressure
Material
Maximum current consumption (excluding loop current for P2VA2)
Maximum power consumption
Measuring range
Output characteristics Cutoff frequency (-1dB)
Output characteristics Cutoff frequency (-3dB)
Output characteristics Maximum output signal
Output characteristics Nonlinearity including hysteresis
Output characteristics Repeatability according to DIN 1319
Output characteristics Resistance value
Output characteristics Sensitivity
Output characteristics Sensitivity error
Output characteristics Sensor authentication method
Output characteristics Zero point error
Rated range of bridge applied voltage
Self-volume (approximate)
Standard temperature
Standard voltage
Temperature compensation range
Part Number
P2VA2Handling Company
Hottinger Brüel & KjærCategories
Image | Price (excluding tax) | Allowable temperature range | Control volume (approximate) | Effect of power supply (with a change of 15V to 30V) | Input characteristics Accuracy class | Input characteristics Dynamic pressure Allowable pressure | Input characteristics Dynamic pressure Allowable vibration amplitude | Input characteristics Initial value | Input characteristics Limit pressure at standard temperature | Input characteristics Operating range at standard temperature | Input characteristics Pressure type | Input characteristics Test pressure | Material | Maximum current consumption (excluding loop current for P2VA2) | Maximum power consumption | Measuring range | Output characteristics Cutoff frequency (-1dB) | Output characteristics Cutoff frequency (-3dB) | Output characteristics Maximum output signal | Output characteristics Nonlinearity including hysteresis | Output characteristics Repeatability according to DIN 1319 | Output characteristics Resistance value | Output characteristics Sensitivity | Output characteristics Sensitivity error | Output characteristics Sensor authentication method | Output characteristics Zero point error | Rated range of bridge applied voltage | Self-volume (approximate) | Standard temperature | Standard voltage | Temperature compensation range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | -20~+85℃ | 1.5mm3 | 0.02% | 0.3 | 100% | 70% (dynamic load according to DIN 50100) | 0 | 150% | 0 to approx. 110 (voltage output), 0 to approx. 105 (current output) | Absolute pressure | 150~200% | 1.4542 (Measurement object), 1.4301 (Seal) | 25mA | <1W (voltage output), <2W (current output) | 100~7,000bar | 2kHz | 4.5kHz | 10.5V, 21.6mA | 0.30% | <±0.05% | ≧10,000 (min) voltage output, ≦500 (max) current output | 0.5~10V, 4~20 (16) mA | <±0.010~±0.020V, <±0.016~<±0.032mA (P2VA2 specifications) | TEDS | <±0.010~±0.020V, <±0.016~<±0.032mA (P2VA2 specifications) | 15~30V (In P2VA2, at the maximum operating temperature or maximum power supply, the maximum allowable power exceeds the specification value. Therefore, the maximum operating temperature is 70℃ instead of 85℃ for P2VA1) | 0.8cm3 | 24V | 0~+70℃ |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.