You can search for other models from each index. The displayed value is the value of the currently selected part number.
Accuracy class based on OIML R60
Allowable temperature range Btu
Breaking load Ed
Bridge applied voltage range Bu
Creep, 30 minutes dDR
Hysteresis error dhy
Input resistance RLC
Insulation resistance Ris
Limit load EL
Maximum capacity Emax (OIML R60)
Maximum load cell division number (OIML R60)
Minimum verification scale Vmin (OIML R60)
Nonlinearity dlin
Output resistance R0
Reference bridge applied voltage Uref
Sensitivity Cn
Sensitivity error when loading in a specific direction
Storage temperature range Btl
Temperature compensation range BT
Temperature effect on sensitivity TKc
Temperature effect on zero point TC0
Y value (OIML R60)
Maximum capacity Emax (OIML IIIM)
Maximum load cell division number (OIML IIIM)
Minimum verification scale Vmin (OIML IIIM)
Part Number
Z6 (F/G) D1Product
Beam type load cell Z6Handling Company
Hottinger Brüel & KjærCategories
Image | Price (excluding tax) | Accuracy class based on OIML R60 () | Allowable temperature range Btu () | Breaking load Ed () | Bridge applied voltage range Bu () | Creep, 30 minutes dDR () | Hysteresis error dhy () | Input resistance RLC () | Insulation resistance Ris () | Limit load EL () | Maximum capacity Emax (OIML R60) () | Maximum load cell division number (OIML R60) () | Minimum verification scale Vmin (OIML R60) () | Nonlinearity dlin () | Output resistance R0 () | Reference bridge applied voltage Uref () | Sensitivity Cn () | Sensitivity error when loading in a specific direction () | Storage temperature range Btl () | Temperature compensation range BT () | Temperature effect on sensitivity TKc () | Temperature effect on zero point TC0 () | Y value (OIML R60) () |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Available upon quote | D1 | -30~+70℃ | ≧300 (% of Emax) | 0.5~12V | ±0.0490 (% of Cn/10K) | ±0.0500 (% of Cn/10K) (Values for nonlinearity, hysteresis error, and temperature effect on sensitivity are recommended values. Their combined value is within the cumulative error specified by OIML R60) | 350~480Ω | >5GΩ | 150 (% of Emax) | 5kg~1t | 1,000 | 0.036 (% of Emax) | ±0.0500 (% of Cn/10K) (Values for nonlinearity, hysteresis error, and temperature effect on sensitivity are recommended values. Their combined value is within the cumulative error specified by OIML R60) | 356±0.2Ω | 5V | 2mV/V | + (1;-0.1) | -50~+85℃ | -10~+40℃ | ±0.0500 (% of Cn/10K) (Values for nonlinearity, hysteresis error, and temperature effect on sensitivity are recommended values. Their combined value is within the cumulative error specified by OIML R60) | ±0.0500 (% of Cn/10K) | 2,778 (% of Emax) |