All Categories

History

Air management hub-Nippon Dick Co., Ltd.

Price (excluding tax)

Estimate Required

Nippon Dick Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

14.2hours

Relatively Fast Response


Model Filter

You can search for other models from each index. The displayed value is the value of the currently selected part number.

Electrical indicator

Electrical power supply voltage

Electrical specification current consumption

Electrical specification protection

Electrical specifications Current consumption

Electrical specifications Power supply voltage

Electrical specifications indicator

Electrical specifications protection

Environment Ambient humidity

Environment Installation location

Environment Operating temperature range

Environment Storage temperature range

Environment altitude

Environment pollution degree

Environment protection structure

Environmental altitude

Environmental and humidity

Environmental installation location

Environmental pollution

Environmental preservation temperature range

Environmental protection structure

Environmental standards

Environmental use temperature range

Flow -up specification pressure characteristics

Flow -up specification repetition accuracy

Flow -up specification setting settings minimum unit accumulation flow rate

Flow -up specification settings minimum unit instantaneous flow rate

Flow -up specification specification flow rate range

Flow -up specification temperature characteristic

Flow rate specification accuracy

Flow rate specification rated rated flow rate range

Flow rate specification unit

Flow rate specifications Accumulated flow range

Flow rate specifications Accuracy

Flow rate specifications Minimum setting unit Instantaneous flow rate

Flow rate specifications Minimum setting unit Total flow rate

Flow rate specifications Pressure characteristics

Flow rate specifications Repeatability

Flow rate specifications Temperature characteristics

Flow specification Rated flow range

Flow specification unit

Fluid Measuring fluid

Fluid fluid temperature

Fluid measurement fluid

Input / output user setting Port Number of empty ports

Input/Output User configurable ports Number of free ports

Pressure specification accuracy

Pressure specification pressure -bearing pressure

Pressure specification rated pressure range

Pressure specification repetition accuracy

Pressure specification temperature characteristics

Pressure specification unit

Pressure specifications

Pressure specifications Rated pressure range

Pressure specifications Repeatability

Pressure specifications Temperature characteristics

Pressure specifications Unit

Pressure specifications accuracy

Temperature specification accuracy

Temperature specification rated temperature range

Temperature specification unit

Temperature specifications Accuracy

Temperature specifications Rated temperature range

See all 4 models in list
  • Part Number

    EXA1-30

Share this product


310+ people viewing

Last viewed: 11 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

Air management hub EXA1-30's performance table

Image Price (excluding tax) Electrical indicator Electrical power supply voltage Electrical specification current consumption Electrical specification protection Electrical specifications Current consumption Electrical specifications Power supply voltage Electrical specifications indicator Electrical specifications protection Environment Ambient humidity Environment Installation location Environment Operating temperature range Environment Storage temperature range Environment altitude Environment pollution degree Environment protection structure Environmental altitude Environmental and humidity Environmental installation location Environmental pollution Environmental preservation temperature range Environmental protection structure Environmental standards Environmental use temperature range Flow -up specification pressure characteristics Flow -up specification repetition accuracy Flow -up specification setting settings minimum unit accumulation flow rate Flow -up specification settings minimum unit instantaneous flow rate Flow -up specification specification flow rate range Flow -up specification temperature characteristic Flow rate specification accuracy Flow rate specification rated rated flow rate range Flow rate specification unit Flow rate specifications Accumulated flow range Flow rate specifications Accuracy Flow rate specifications Minimum setting unit Instantaneous flow rate Flow rate specifications Minimum setting unit Total flow rate Flow rate specifications Pressure characteristics Flow rate specifications Repeatability Flow rate specifications Temperature characteristics Flow specification Rated flow range Flow specification unit Fluid Measuring fluid Fluid fluid temperature Fluid measurement fluid Input / output user setting Port Number of empty ports Input/Output User configurable ports Number of free ports Pressure specification accuracy Pressure specification pressure -bearing pressure Pressure specification rated pressure range Pressure specification repetition accuracy Pressure specification temperature characteristics Pressure specification unit Pressure specifications Pressure specifications Rated pressure range Pressure specifications Repeatability Pressure specifications Temperature characteristics Pressure specifications Unit Pressure specifications accuracy Temperature specification accuracy Temperature specification rated temperature range Temperature specification unit Temperature specifications Accuracy Temperature specifications Rated temperature range
Air management hub-Part Number-EXA1-30 Available upon quote LED & LCD DC24V ± 10 % 400ma Reverse connection protection, overcurrent protection 400mA DC24V±10% LED&LCD Reverse connection protection, overcurrent protection 35~85%RH outdoor 0~50℃ (No freezing or condensation) -10~60℃ (No freezing or condensation) Up to 3,000m 3 IP65 (electrical equipment only) Compliant with IEC60529 Up to 3,000m 35-85 % RH Outdoors 3 -10 to 60 ° C (freezing and without condensation) IP65 (only for electrical equipment) complies with IEC60529 CE/UKCA marking, UL (CSA) 0 to 50 ° C (freezing and without condensation) ± 5.0 % F.S. ± 1.0 % F.S. 10L 1L/min 0 ~ 9,999,999,990L ± 5.0 % F.S. (0 to 50 ° C, 25 ° C standard) ± 3.0 % F.S. 10 ~ 1,000L/min L/Min, CFM (FT3/Min) 0~9,999,999,990L ±3.0%F.S. 1L/min 10L ±5.0%F.S. (0~1.0MPa 0.5MPa standard) ±1.0%F.S. ±5.0%F.S. (0~50℃, 25℃ standard) 10~1,000L/min L/min, CFM (ft3/min) air 0~50℃ air 1 1 ± 3.0 % F.S. 1.5MPA 0 ~ 1.0MPa ± 1.0 % F.S. ± 5.0 % F.S. (0 to 50 ° C, 25 ° C standard) MPA, KPA, KGF/CM2, Bar, PSI 1.5MPa 0~1.0MPa ±1.0%F.S. ±5.0%F.S. (0~50℃, 25℃ standard) MPa, kPa, kgf/cm2, bar, psi ±3.0%F.S. ± 2.5 ℃ (flow range 10 % to 100 %) 0 to 50 ℃ ℃, ℉ ±2.5℃ (Flow rate range 10%~100%) 0~50℃

There are 4 models for this product.

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Factory Visualization Softwares Products

Other products of Nippon Dick Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Nippon Dick Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

14.2hrs


Company Review

5.0
  • Japan

Category of this product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree