All Categories
History
Relatively Fast Response
Product
Hygiene management equipment High level of cleanliness fosters trust. The secret of Selius soft water is in "pH" Selius soft water generator SeliusHandling Company
Kyushu Kiden Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Weight | Piping diameter (water inlet) | Piping diameter (water spout) | Production amount | Additive liquid | Residual chlorine concentration (standard specification) | Residual chlorine concentration (low concentration specification) | Dimensions (including piping) | Size | Rating | Safety equipment | Ambient temperature | Usable water supply pressure | Fluid temperature used | Usable water amount | PH value |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NDX-1500PLB |
Available upon quote |
Approximately 80kg (dry) |
PVC union (screw type) PT3/4" (20A) |
PVC union (screw type) PT3/4" (20A) |
Maximum approximately 1,500 (±120) L/h |
Sodium hypochlorite (NaCIO), hydrochloric acid (HCI) |
Approximately 100,200mg/L (ppm) 2-step switching |
Approximately 50,100mg/L (ppm) 2-step switching |
W974×H1,275×D553 (mm) |
W800×H1,275×D553 (mm) |
AC100V4.4A50/60Hz |
PH measurement device, additive liquid shortage sensor, water supply amount monitoring, earth leakage sensor, liquid leakage sensor, additive liquid pump operation monitoring |
35~85%RH (no condensation) |
0.25~0.75MPa (0.25MPa or more is always required) |
5~35℃ (no freezing) |
5~25L/min |
PH variable setting type (raw water ±0.5) |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
32.7hrs
Company Review
5.0