Product
Platinum sensor with lead wire for high temperature measurement 600℃ seriesHandling Company
OG Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Characteristic curve | Lead wire | Long term stability | Nominal resistance value | Operating temperature range | Other special specifications | Permissible class | Recommended circuit current value | Special lead wire |
---|---|---|---|---|---|---|---|---|---|---|---|
P0K1.161.6W.Y.007 |
Available upon quote | 3,850ppm/K | Platinum clad nickel wire, Φ0.2mm (solderable, weldable, crimpable, brazeable) | <0.04% at 1,000h (at maximum operating temperature) | 100Ω at 0℃ | -200℃~+600℃ | Cylindrical ceramic housing (for dry environments), grouping and pairing, board thickness | IEC 60751 F0.1 (class Y) | 1mA at 100Ω | Direction lead wire |