Product
Multifunctional DC-AC inverter "NTN-5K Series" that can be used with three-phase, four-wire and connect up to 6 units in parallel.Handling Company
Earth Power Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Charging current | Charging range | Communication | Continuous output | Efficiency | Float charge | Input side current | Input side protection low voltage | Input side protection overvoltage | Input voltage range | Instantaneous output | Maximum charging power | Maximum output | No-load standby power | Operating humidity range | Operating temperature range | Output frequency | Output side protection | Output voltage fluctuation value | Output waveform | Overload | Parc charge | Rated input voltage | Remote control | Reverse connection | Side rated output voltage | Storage temperature range | Temperature compensation | UPS mode | When power is OFF |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NTN-5K-124 |
Available upon quote | 120A | DC21.0V~DC30.0V | MODBus-RTU (RS-485) /CANBus | 4,000W | 89.00% | DC27.6V | 200A |
Alarm DC22.0V and DC0.5V Shutoff DC20.0V SatDC0.5V Restart DC25.0V SatDC0.5V |
Overvoltage alarm OC31.0V DC0.5V Overvoltage cutoff DC33.0V SatDC0.5V Restart DC30.0V and DC0.5V |
DC20.0V~DC33.0V | 7,000W | 3,600W |
(10sec) 5,600W (180sec) 4,600W |
Power save OFF:2.5A Power save ON: When the side standby power connection load capacity is 10W or less, Automatically shifts to power saving mode <25W |
20%~90%RH (No condensation) |
-30~70℃ | At the time of shipment: 60-shi 0.1Hz (50-shi 0.1Hz/60-shi 0.1Hz switchable) |
Overtemperature After overvoltage protection is detected and operation stops, automatic recovery occurs when temperature is resolved. Short circuit Disconnect the connection and turn the power back on to recover. circuit breaker 50A |
3.0% (input side: rated output value at DC25.0V/DC50.0V) | Sine wave (distortion rate: 3.0% or less) |
180 seconds 105~115% of load capacity 115~140% of load capacity for 10 seconds |
DC28.8V | DC24V | Output side ON/OFF remote terminal (RC terminal) |
Error After disconnecting all connections Recovers when power is turned on again |
Factory shipped AC110V (AC100V/AC115V/AC120V switchable) | -30~+70℃ | External temperature sensor |
AC input range AC100V AC110V AC115V AC120V 16% Frequency range 45Hz~65Hz Switching time Inverter mode UPS mode Switching in 001 seconds |
≦1mA | |
NTN-5K-148 |
Available upon quote | 60A | DC42.0V~DC60.0V | MODBus-RTU (RS-485) /CANBus | 4,000W | 91.00% | DC55.2V | 100A |
Alarm DC44.0V and DC1.0V Cutoff DC40.0V and DC1.0V Restart DC50.0V and DC1.0V |
Overvoltage alarm DC62.0V and DC1.0V Overvoltage cutoff DC66.0V and DC1.0V Restart DC60.0V and DC1.0V |
DC40.0V~DC66.0V | 8,000W | 3,600W |
(10sec) 6,000W (180sec) 4,600W |
Power save OFF: 1.4A Power save ON: When the side standby power connection load capacity is 10W or less, Automatically shifts to power saving mode <25W |
20%~90%RH (No condensation) |
-30~70℃ | At the time of shipment: 60-shi 0.1Hz (50-shi 0.1Hz/60-shi 0.1Hz switchable) |
Overtemperature After overvoltage protection is detected and operation stops, automatic recovery occurs when temperature is resolved. Short circuit Disconnect the connection and turn the power back on to recover. circuit breaker 50A |
3.0% (input side: rated output value at DC25.0V/DC50.0V) | Sine wave (distortion rate: 3.0% or less) |
180 seconds 105~115% of load capacity 115~150% of load capacity for 10 seconds |
DC57.6V | DC48V | Output side ON/OFF remote terminal (RC terminal) |
Error After disconnecting all connections Recovers when power is turned on again |
Factory shipped AC110V (AC100V/AC115V/AC120V switchable) | -30~+70℃ | External temperature sensor |
AC input range AC100V AC110V AC115V AC120V 16% Frequency range 45Hz~65Hz Switching time Inverter mode UPS mode Switching in 001 seconds |
≦1mA | |
NTN-5K-224 |
Available upon quote | 135A | DC21.0V~DC30.0V | MODBus-RTU (RS-485) /CANBus | 5,000W | 91.00% | DC27.6V | 240A |
Alarm DC22.0V SatDC0.5V Shutoff DC20.0V SatDC0.5V Restart DC25.0V and DC0.5V |
Overvoltage alarm DC31.0V and DC0.5V Overvoltage cutoff DC33.0V and DC0.5V Restart DC30.0V and DC0.5V |
DC20.0V~DC33.0V | 8,000W | 4,050W |
(10sec) 7,000W (180sec) 5,750W |
Power save OFF:2.5A Power save ON: When the side standby power connection load capacity is 10W or less, Automatically shifts to power saving mode <25W |
20%~90%RH (No condensation) |
-30~70℃ | When shipped: 50-shi 0.1Hz (50-shi 0.1Hz/60-shi 0.1Hz switchable) |
Overtemperature After overvoltage protection is detected and operation stops, automatic recovery occurs when temperature is resolved. Short circuit Disconnect the connection and turn the power back on to recover. circuit breaker 35A |
3.0% (input side: rated output value at DC25.0V/DC50.0V/DC400) | Sine wave (distortion rate: 3.0% or less) |
180 seconds 105~115% of load capacity 115~140% of load capacity for 10 seconds |
DC28.8V | DC24V | Output side ON/OFF remote terminal (RC terminal) |
Error After disconnecting all connections Recovers when power is turned on again |
At time of shipment: AC230V (AC200V/AC220V/AC240V switchable) | -30~+70℃ | External temperature sensor |
AC input range AC200V AC220V AC230V AC240V 16% Frequency range 45Hz~65Hz Switching time Inverter mode UPS mode Switching in 001 seconds |
≦1mA | |
NTN-5K-248 |
Available upon quote | 70A | DC42.0V~DC60.0V | MODBus-RTU (RS-485) /CANBus | 5,000W | 93.00% | DC55.2V | 120A |
Alarm DC44.0V SatDC1.0V Shutoff DC40.0V SatDC1.0V Restart DC50.0V and DC1.0V |
Overvoltage alarm DC62.0V and DC1.0V Overvoltage cutoff DC66.0V and DC1.0V Restart DC60.0V and DC1.0V |
DC40.0V~DC66.0V | 8,000W | 4,200W |
(10sec) 7,500W (180sec) 5,750W |
Power save OFF: 1.4A Power save ON: When the side standby power connection load capacity is 10W or less, Automatically shifts to power saving mode <25W |
20%~90%RH (No condensation) |
-30~70℃ | When shipped: 50-shi 0.1Hz (50-shi 0.1Hz/60-shi 0.1Hz switchable) |
Overtemperature After overvoltage protection is detected and operation stops, automatic recovery occurs when temperature is resolved. Short circuit Disconnect the connection and turn the power back on to recover. circuit breaker 35A |
3.0% (input side: rated output value at DC25.0V/DC50.0V/DC400) | Sine wave (distortion rate: 3.0% or less) |
180 seconds 105~115% of load capacity 115~150% of load capacity for 10 seconds |
DC57.6V | DC48V | Output side ON/OFF remote terminal (RC terminal) |
Error After disconnecting all connections Recovers when power is turned on again |
At time of shipment: AC230V (AC200V/AC220V/AC240V switchable) | -30~+70℃ | External temperature sensor |
AC input range AC200V AC220V AC230V AC240V 16% Frequency range 45Hz~65Hz Switching time Inverter mode UPS mode Switching in 001 seconds |
≦1mA | |
NTN-5K-2380 |
Available upon quote | 11.3A | DC300V~DC400V | MODBus-RTU (RS-485) /CANBus | 5,000W | 94.50% | DC385V | 16A |
Alarm DC300.0V SatDC5.0V Shutoff DC280.0V SatDC5.0V Restart DC335.0V and DC5.0V |
Overvoltage alarm DC420.0V and DC5.0V Overvoltage cutoff DC430.0V and DC5.0V Restart DC400.0V and DC5.0V |
DC280V~DC430V | 10,000W | 4,520W |
(10sec) 7,500W (180sec) 5,750W |
Power save OFF:0.2A Power save ON: When the side standby power connection load capacity is 10W or less, Automatically shifts to power saving mode <25W |
20%~90%RH (No condensation) |
-30~70℃ | When shipped: 50-shi 0.1Hz (50-shi 0.1Hz/60-shi 0.1Hz switchable) |
Overtemperature After overvoltage protection is detected and operation stops, automatic recovery occurs when temperature is resolved. Short circuit Disconnect the connection and turn the power back on to recover. circuit breaker 35A |
3.0% (input side: rated output value at DC25.0V/DC50.0V/DC400) | Sine wave (distortion rate: 3.0% or less) |
180 seconds 105~115% of load capacity 115~150% of load capacity for 10 seconds |
DC400V | DC380V | Output side ON/OFF remote terminal (RC terminal) |
Error After disconnecting all connections Recovers when power is turned on again |
At time of shipment: AC230V (AC200V/AC220V/AC240V switchable) | -30~+70℃ | External temperature sensor |
AC input range AC200V AC220V AC230V AC240V 16% Frequency range 45Hz~65Hz Switching time Inverter mode UPS mode Switching in 001 seconds |
≦1mA |
Click on the part number for more information about each product