Oxygen Nitrogen Hydrogen Analyzer ONH836 Series-ONH836
Oxygen Nitrogen Hydrogen Analyzer ONH836 Series-Cosmo Trading Co., Ltd.

Oxygen Nitrogen Hydrogen Analyzer ONH836 Series
Cosmo Trading Co., Ltd.


About This Product

■Features Analyzes oxygen, nitrogen, and hydrogen in all inorganic substances using the inert gas melting method. Three oxygen-sensing infrared (IR) detectors enable the industry's largest analysis range. ■Analysis target Steel, cast iron, ferroalloy, titanium alloy, zirconium, uranium, mold powder, copper alloy, aluminum alloy, ceramics, etc. The oxygen/nitrogen/hydrogen analyzer ONH836 is a wide range type that has been realized using cutting-edge technology based on customer feedback and requests over many years. We measure oxygen, nitrogen, and hydrogen in all inorganic materials such as steel, nonferrous metals, high-melting point metals, and ceramics using the inert gas fusion method. All operations such as instrument control, analysis condition settings, diagnostics and report printing are performed via a Windows®-based touchscreen interface mounted on the flexible arm, saving valuable work space. There is nothing wrong. Features and benefits ■Excellent features - Three oxygen detection infrared (IR) detectors enable the industry's largest analysis range. ・Patented Dynamic Flow Compensation (DFC) further increases the stability of the TC cell. ・The latest patent-pending IR detector has further improved long-term stability with an emitter drive and drift-free detection circuit. vinegar. - Patent-pending high-efficiency cleaning system reduces manual cleaning and provides dust-free operation. ■ Comprehensive sample loading area -Minimizes atmospheric entrainment when introducing samples. - Regular maintenance of the sample drop mechanism has been simplified. - Disc filter replacement is now easier. - The OMI tube (reagent for removing oxygen and moisture in carrier gas) is easier to replace and has a longer lifespan by bypassing it. ■Highly reliable automation mechanism - By installing an optional auto cleaner, manual cleaning between samples can be minimized. ・Optional batch loader for 20 samples can also be installed. ■Others -Ergonomic and intuitive operation is possible with the touch panel interface attached to the flexible arm. ・Pressure-compensated, temperature-controlled gas dosing system. - The latest piping minimizes joints that can cause damage or leaks.

  • Product

    Oxygen Nitrogen Hydrogen Analyzer ONH836 Series

Share this product


120+ people viewing

Last viewed: 18 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

7 Models of Oxygen Nitrogen Hydrogen Analyzer ONH836 Series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Analysis range (sample weight 1g) Analysis time Analytical accuracy (sample weight 1g) Calibration Detection method Gas flow rate Gas options Gas used Internal cooling water Operating environment Part number Power capacity Reagent Sample weight Size Weight
Oxygen Nitrogen Hydrogen Analyzer ONH836 Series-Part Number-ONH836

ONH836

Available upon quote Oxygen: 0.05ppm~5.0%
Nitrogen (carrier gas helium): 0.05ppm~3.0%
Nitrogen (carrier gas argon): 0.2ppm~3.0%
Hydrogen: 0.1ppm~2,500ppm
Oxygen [carrier gas helium]: 85 seconds, [carrier gas argon]: 95 seconds, etc.
(Including outgassing, purge, and analysis delay)
Oxygen: Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is greater
Nitrogen (carrier gas helium): Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is larger, etc.
Standard sample (1 point or multiple points), manual: gas dose Oxygen, hydrogen: non-dispersive infrared absorption method
Nitrogen: thermal conductivity method
Carrier: 490cc/min
Drive: 280cc/min
Gas dose: carbon dioxide (99.99%) 0.14MPa, nitrogen (99.99%) 0.14MPa Carrier: Helium (99.99%), 0.15MPa or Argon (99.999%), 0.15MPa
Drive: Dry nitrogen, 0.28MPa (contains no moisture or oil)
Distilled water 3.2 L Temperature: 15℃~35℃
Relative humidity: 20%~80% (non-condensing)
[ONH836-MC]
Oxygen/nitrogen/hydrogen analyzer, mount type monitor
[ONH836-HMC]
Oxygen/nitrogen/hydrogen analyzers, auto cleaners, mount type monitors, etc.
Single phase 200V~ (+10/-15%: maximum output, boosted to 230V), 50/60Hz, 30A, 12,500BTU/hr
*Average when operating with normal settings
・Magnesium perchlorate
・Copper oxide, reduced copper
・Sodium hydroxide (coated on an inert substrate)
・Oxygen water removal agent (OMI tube)
Usually 1g Width: 71cm
Depth: with touch screen monitor (85cm)
No touch screen monitor (76cm)
Height: When using road head cover lift (100cm), Normally (91.5cm)
Body weight 186kg (without touch screen monitor)
Oxygen Nitrogen Hydrogen Analyzer ONH836 Series-Part Number-ON836

ON836

Available upon quote Oxygen: 0.05ppm~5.0%
Nitrogen (carrier gas helium): 0.05ppm~3.0%
Nitrogen (carrier gas argon): 0.2ppm~3.0%
Hydrogen: 0.1ppm~2,500ppm
Oxygen [carrier gas helium]: 85 seconds, [carrier gas argon]: 95 seconds, etc.
(Including outgassing, purge, and analysis delay)
Oxygen: Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is greater
Nitrogen (carrier gas helium): Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is larger, etc.
Standard sample (1 point or multiple points), manual: gas dose Oxygen, hydrogen: non-dispersive infrared absorption method
Nitrogen: thermal conductivity method
Carrier: 490cc/min
Drive: 280cc/min
Gas dose: carbon dioxide (99.99%) 0.14MPa, nitrogen (99.99%) 0.14MPa Carrier: Helium (99.99%), 0.15MPa or Argon (99.999%), 0.15MPa
Drive: Dry nitrogen, 0.28MPa (contains no moisture or oil)
Distilled water 3.2 L Temperature: 15℃~35℃
Relative humidity: 20%~80% (non-condensing)
[ONH836-MC]
Oxygen/nitrogen/hydrogen analyzer, mount type monitor
[ONH836-HMC]
Oxygen/nitrogen/hydrogen analyzers, auto cleaners, mount type monitors, etc.
Single phase 200V~ (+10/-15%: maximum output, boosted to 230V), 50/60Hz, 30A, 12,500BTU/hr
*Average when operating with normal settings
・Magnesium perchlorate
・Copper oxide, reduced copper
・Sodium hydroxide (coated on an inert substrate)
・Oxygen water removal agent (OMI tube)
Usually 1g Width: 71cm
Depth: with touch screen monitor (85cm)
No touch screen monitor (76cm)
Height: When using road head cover lift (100cm), Normally (91.5cm)
Body weight 186kg (without touch screen monitor)
Oxygen Nitrogen Hydrogen Analyzer ONH836 Series-Part Number-OH836

OH836

Available upon quote Oxygen: 0.05ppm~5.0%
Nitrogen (carrier gas helium): 0.05ppm~3.0%
Nitrogen (carrier gas argon): 0.2ppm~3.0%
Hydrogen: 0.1ppm~2,500ppm
Oxygen [carrier gas helium]: 85 seconds, [carrier gas argon]: 95 seconds, etc.
(Including outgassing, purge, and analysis delay)
Oxygen: Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is greater
Nitrogen (carrier gas helium): Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is larger, etc.
Standard sample (1 point or multiple points), manual: gas dose Oxygen, hydrogen: non-dispersive infrared absorption method
Nitrogen: thermal conductivity method
Carrier: 490cc/min
Drive: 280cc/min
Gas dose: carbon dioxide (99.99%) 0.14MPa, nitrogen (99.99%) 0.14MPa Carrier: Helium (99.99%), 0.15MPa or Argon (99.999%), 0.15MPa
Drive: Dry nitrogen, 0.28MPa (contains no moisture or oil)
Distilled water 3.2 L Temperature: 15℃~35℃
Relative humidity: 20%~80% (non-condensing)
[ONH836-MC]
Oxygen/nitrogen/hydrogen analyzer, mount type monitor
[ONH836-HMC]
Oxygen/nitrogen/hydrogen analyzers, auto cleaners, mount type monitors, etc.
Single phase 200V~ (+10/-15%: maximum output, boosted to 230V), 50/60Hz, 30A, 12,500BTU/hr
*Average when operating with normal settings
・Magnesium perchlorate
・Copper oxide, reduced copper
・Sodium hydroxide (coated on an inert substrate)
・Oxygen water removal agent (OMI tube)
Usually 1g Width: 71cm
Depth: with touch screen monitor (85cm)
No touch screen monitor (76cm)
Height: When using road head cover lift (100cm), Normally (91.5cm)
Body weight 186kg (without touch screen monitor)
Oxygen Nitrogen Hydrogen Analyzer ONH836 Series-Part Number-NH836

NH836

Available upon quote Oxygen: 0.05ppm~5.0%
Nitrogen (carrier gas helium): 0.05ppm~3.0%
Nitrogen (carrier gas argon): 0.2ppm~3.0%
Hydrogen: 0.1ppm~2,500ppm
Oxygen [carrier gas helium]: 85 seconds, [carrier gas argon]: 95 seconds, etc.
(Including outgassing, purge, and analysis delay)
Oxygen: Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is greater
Nitrogen (carrier gas helium): Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is larger, etc.
Standard sample (1 point or multiple points), manual: gas dose Oxygen, hydrogen: non-dispersive infrared absorption method
Nitrogen: thermal conductivity method
Carrier: 490cc/min
Drive: 280cc/min
Gas dose: carbon dioxide (99.99%) 0.14MPa, nitrogen (99.99%) 0.14MPa Carrier: Helium (99.99%), 0.15MPa or Argon (99.999%), 0.15MPa
Drive: Dry nitrogen, 0.28MPa (contains no moisture or oil)
Distilled water 3.2 L Temperature: 15℃~35℃
Relative humidity: 20%~80% (non-condensing)
[ONH836-MC]
Oxygen/nitrogen/hydrogen analyzer, mount type monitor
[ONH836-HMC]
Oxygen/nitrogen/hydrogen analyzers, auto cleaners, mount type monitors, etc.
Single phase 200V~ (+10/-15%: maximum output, boosted to 230V), 50/60Hz, 30A, 12,500BTU/hr
*Average when operating with normal settings
・Magnesium perchlorate
・Copper oxide, reduced copper
・Sodium hydroxide (coated on an inert substrate)
・Oxygen water removal agent (OMI tube)
Usually 1g Width: 71cm
Depth: with touch screen monitor (85cm)
No touch screen monitor (76cm)
Height: When using road head cover lift (100cm), Normally (91.5cm)
Body weight 186kg (without touch screen monitor)
Oxygen Nitrogen Hydrogen Analyzer ONH836 Series-Part Number-O836

O836

Available upon quote Oxygen: 0.05ppm~5.0%
Nitrogen (carrier gas helium): 0.05ppm~3.0%
Nitrogen (carrier gas argon): 0.2ppm~3.0%
Hydrogen: 0.1ppm~2,500ppm
Oxygen [carrier gas helium]: 85 seconds, [carrier gas argon]: 95 seconds, etc.
(Including outgassing, purge, and analysis delay)
Oxygen: Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is greater
Nitrogen (carrier gas helium): Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is larger, etc.
Standard sample (1 point or multiple points), manual: gas dose Oxygen, hydrogen: non-dispersive infrared absorption method
Nitrogen: thermal conductivity method
Carrier: 490cc/min
Drive: 280cc/min
Gas dose: carbon dioxide (99.99%) 0.14MPa, nitrogen (99.99%) 0.14MPa Carrier: Helium (99.99%), 0.15MPa or Argon (99.999%), 0.15MPa
Drive: Dry nitrogen, 0.28MPa (contains no moisture or oil)
Distilled water 3.2 L Temperature: 15℃~35℃
Relative humidity: 20%~80% (non-condensing)
[ONH836-MC]
Oxygen/nitrogen/hydrogen analyzer, mount type monitor
[ONH836-HMC]
Oxygen/nitrogen/hydrogen analyzers, auto cleaners, mount type monitors, etc.
Single phase 200V~ (+10/-15%: maximum output, boosted to 230V), 50/60Hz, 30A, 12,500BTU/hr
*Average when operating with normal settings
・Magnesium perchlorate
・Copper oxide, reduced copper
・Sodium hydroxide (coated on an inert substrate)
・Oxygen water removal agent (OMI tube)
Usually 1g Width: 71cm
Depth: with touch screen monitor (85cm)
No touch screen monitor (76cm)
Height: When using road head cover lift (100cm), Normally (91.5cm)
Body weight 186kg (without touch screen monitor)
Oxygen Nitrogen Hydrogen Analyzer ONH836 Series-Part Number-N836

N836

Available upon quote Oxygen: 0.05ppm~5.0%
Nitrogen (carrier gas helium): 0.05ppm~3.0%
Nitrogen (carrier gas argon): 0.2ppm~3.0%
Hydrogen: 0.1ppm~2,500ppm
Oxygen [carrier gas helium]: 85 seconds, [carrier gas argon]: 95 seconds, etc.
(Including outgassing, purge, and analysis delay)
Oxygen: Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is greater
Nitrogen (carrier gas helium): Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is larger, etc.
Standard sample (1 point or multiple points), manual: gas dose Oxygen, hydrogen: non-dispersive infrared absorption method
Nitrogen: thermal conductivity method
Carrier: 490cc/min
Drive: 280cc/min
Gas dose: carbon dioxide (99.99%) 0.14MPa, nitrogen (99.99%) 0.14MPa Carrier: Helium (99.99%), 0.15MPa or Argon (99.999%), 0.15MPa
Drive: Dry nitrogen, 0.28MPa (contains no moisture or oil)
Distilled water 3.2 L Temperature: 15℃~35℃
Relative humidity: 20%~80% (non-condensing)
[ONH836-MC]
Oxygen/nitrogen/hydrogen analyzer, mount type monitor
[ONH836-HMC]
Oxygen/nitrogen/hydrogen analyzers, auto cleaners, mount type monitors, etc.
Single phase 200V~ (+10/-15%: maximum output, boosted to 230V), 50/60Hz, 30A, 12,500BTU/hr
*Average when operating with normal settings
・Magnesium perchlorate
・Copper oxide, reduced copper
・Sodium hydroxide (coated on an inert substrate)
・Oxygen water removal agent (OMI tube)
Usually 1g Width: 71cm
Depth: with touch screen monitor (85cm)
No touch screen monitor (76cm)
Height: When using road head cover lift (100cm), Normally (91.5cm)
Body weight 186kg (without touch screen monitor)
Oxygen Nitrogen Hydrogen Analyzer ONH836 Series-Part Number-H836

H836

Available upon quote Oxygen: 0.05ppm~5.0%
Nitrogen (carrier gas helium): 0.05ppm~3.0%
Nitrogen (carrier gas argon): 0.2ppm~3.0%
Hydrogen: 0.1ppm~2,500ppm
Oxygen [carrier gas helium]: 85 seconds, [carrier gas argon]: 95 seconds, etc.
(Including outgassing, purge, and analysis delay)
Oxygen: Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is greater
Nitrogen (carrier gas helium): Standard deviation (s) 0.025ppm or RSD0.3% *Whichever is larger, etc.
Standard sample (1 point or multiple points), manual: gas dose Oxygen, hydrogen: non-dispersive infrared absorption method
Nitrogen: thermal conductivity method
Carrier: 490cc/min
Drive: 280cc/min
Gas dose: carbon dioxide (99.99%) 0.14MPa, nitrogen (99.99%) 0.14MPa Carrier: Helium (99.99%), 0.15MPa or Argon (99.999%), 0.15MPa
Drive: Dry nitrogen, 0.28MPa (contains no moisture or oil)
Distilled water 3.2 L Temperature: 15℃~35℃
Relative humidity: 20%~80% (non-condensing)
[ONH836-MC]
Oxygen/nitrogen/hydrogen analyzer, mount type monitor
[ONH836-HMC]
Oxygen/nitrogen/hydrogen analyzers, auto cleaners, mount type monitors, etc.
Single phase 200V~ (+10/-15%: maximum output, boosted to 230V), 50/60Hz, 30A, 12,500BTU/hr
*Average when operating with normal settings
・Magnesium perchlorate
・Copper oxide, reduced copper
・Sodium hydroxide (coated on an inert substrate)
・Oxygen water removal agent (OMI tube)
Usually 1g Width: 71cm
Depth: with touch screen monitor (85cm)
No touch screen monitor (76cm)
Height: When using road head cover lift (100cm), Normally (91.5cm)
Body weight 186kg (without touch screen monitor)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Cosmo Trading Co., Ltd.


View more products of Cosmo Trading Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree