Demand monitoring device Energy saving system Pulse detector OCK-8A/OCK-8Handling Company
Osaki Electric Industry Co., Ltd.Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply | Atmosphere | Mass | Display numeric LED | Display LED lamp | Compatible power area | External dimensions Main body | External dimensions Pulse detection section | Model name | Installation method | Number of outputs | Output transmission distance | Output Pulse condition Output 3 | Output Pulse conditions Output 1, Output 2 | Number of inputs | Input pulse condition 2 | Input pulse condition 1 | Usage environment | Key operation Confirm | Key operation digit movement | Key operation number feed | Key operation operation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
OCK-8A |
$ 1,053.00〜 |
AC100/110V±10%, 50/60Hz shared, 5VA or less |
Place without corrosive gas, similar to general industrial instruments |
Main body: approx. 500g, pulse detection section: approx. 100g |
Pulse constant, composite metamorphic ratio, pulse width, etc. (red 5-digit numerical display) |
Operation, settings, confirmation, input (all red) |
Hokkaido, Tohoku, Tokyo, Hokuriku, Kansai* ・Chugoku, Shikoku, Kyushu, Okinawa For each power service area |
83mm (W) ×189.5mm (H) ×89mm (D) |
For OCK-8A (OCK-8A-CT): 36mm (W) ×77mm (H) ×36mm (D) |
RPK-19 |
Can be used for both wall mounting and IEC rail mounting |
3 |
Maximum 500m (using CVVS 1.25mm2) |
No-voltage a contact (photomos relay), AC/DC 110V 0.1A or less, 500mW or less, pulse width is the same as input (through output) |
No-voltage a contact (photomos relay), AC/DC110V 0.1A or less 500mW or less |
1 (Pulse detection section, through-type CT) |
2,000pulse/kWh (400Hz modulation pulse): Pulse width 10msec or more, pulse interval 140msec or more, DC pulse current 12mA or more and 40mA or less |
50,000pulse/kWh: Pulse width 10msec or more, pulse interval 60msec or more, DC pulse current 8mA or more and 40mA or less |
Temperature: 10~55℃, Humidity: 90%RH or less (non-condensing) |
Change mode and confirm settings |
Switching the display, moving setting data digits |
Switching the display and changing the numerical value of setting data |
Change operation/setting/confirmation mode |
![]() |
OCK-8 |
$ 1,053.00〜 |
AC100/110V±10%, 50/60Hz shared, 5VA or less |
Place without corrosive gas, similar to general industrial instruments |
Main body: approx. 500g, pulse detection section: approx. 100g |
Pulse constant, composite metamorphic ratio, pulse width, etc. (red 5-digit numerical display) |
Operation, settings, confirmation, input (all red) |
Chubu/Kansai* For each power area |
83mm (W) ×189.5mm (H) ×89mm (D) |
For OCK-8 (OCK-8-CT): 35mm (W) ×50mm (H) ×40mm (D) |
RPK-20 |
Can be used for both wall mounting and IEC rail mounting |
3 |
Maximum 500m (using CVVS 1.25mm2) |
No-voltage a contact (photomos relay), AC/DC 110V 0.1A or less, 500mW or less, pulse width is the same as input (through output) |
No-voltage a contact (photomos relay), AC/DC110V 0.1A or less 500mW or less |
1 (Pulse detection section, through-type CT) |
2,000pulse/kWh (400Hz modulation pulse): Pulse width 10msec or more, pulse interval 140msec or more, DC pulse current 12mA or more and 40mA or less |
50,000pulse/kWh: Pulse width 10msec or more, pulse interval 60msec or more, DC pulse current 8mA or more and 40mA or less |
Temperature: 10~55℃, Humidity: 90%RH or less (non-condensing) |
Change mode and confirm settings |
Switching the display, moving setting data digits |
Switching the display and changing the numerical value of setting data |
Change operation/setting/confirmation mode |