Product
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1rHandling Company
Osaki Electric Industry Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Accessories | Character configuration Parity bit | Character configuration Stop bit | Character configuration data bit | Character configuration start bit | Communication interface | Communication interface Communication code | Communication interface Communication method | Communication interface synchronization method | Communication items | Installation/connection method | Mass (kg) | Phase wire system | Rated current (A) | Rated frequency (Hz) | Rated voltage (V) | Transmission speed | Type | Type approval number (No. ~) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A1GA-TLN1r (30A) |
Available upon quote | Terminal cover (standard equipment) | 1 bit (None/Even number/Odd number) Can be selected by communication setting button |
1 bit/2 bit Can be selected using the communication setting button - 2 bits can be set only when there is no parity |
8 bit | 1 bit | RS-485 communication (in-house telegram) | JISX0201 (8-bit encoded character set) | Half duplex | Start-stop synchronization | Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value | Surface mounting, surface connection | 0.4 | Single phase 2 wire | 30 | 50 or 60 (Unverified products are shared) | 100200240 | 4,800/9,600/19,200bps (selective settings) | Standard product, (BL type) | 4714-2 | |
A1GA-TLN1r (120A) |
Available upon quote | Terminal cover (standard equipment) | 1 bit (None/Even number/Odd number) Can be selected by communication setting button |
1 bit/2 bit Can be selected using the communication setting button - 2 bits can be set only when there is no parity |
8 bit | 1 bit | RS-485 communication (in-house telegram) | JISX0201 (8-bit encoded character set) | Half duplex | Start-stop synchronization | Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value | Surface mounting, surface connection | 0.4 | Single phase 2 wire | 120 | 50 or 60 (Unverified products are shared) | 100200240 | 4,800/9,600/19,200bps (selective settings) | Standard product, (BL type) | 4716-2 | |
A1GA-TLN1r (/5A) |
Available upon quote | Terminal cover (standard equipment) | 1 bit (None/Even number/Odd number) Can be selected by communication setting button |
1 bit/2 bit Can be selected using the communication setting button - 2 bits can be set only when there is no parity |
8 bit | 1 bit | RS-485 communication (in-house telegram) | JISX0201 (8-bit encoded character set) | Half duplex | Start-stop synchronization | Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value | Surface mounting, surface connection | 0.3 | Single phase 2 wire | /5 | 50 or 60 (Unverified products are shared) | /100, 100, 200, 240 | 4,800/9,600/19,200bps (selective settings) | Standard product | 4734-1 | |
A2GA-TLN1r (30A) |
Available upon quote | Terminal cover (standard equipment) | 1 bit (None/Even number/Odd number) Can be selected by communication setting button |
1 bit/2 bit Can be selected using the communication setting button - 2 bits can be set only when there is no parity |
8 bit | 1 bit | RS-485 communication (in-house telegram) | JISX0201 (8-bit encoded character set) | Half duplex | Start-stop synchronization | Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value | Surface mounting, surface connection | 0.5 | Single phase 3 wire | 30 | 50 or 60 (Unverified products are shared) | 100 | 4,800/9,600/19,200bps (selective settings) | Standard product, (BL type) | 4718-2 | |
A2GA-TLN1r (120A) |
Available upon quote | Terminal cover (standard equipment) | 1 bit (None/Even number/Odd number) Can be selected by communication setting button |
1 bit/2 bit Can be selected using the communication setting button - 2 bits can be set only when there is no parity |
8 bit | 1 bit | RS-485 communication (in-house telegram) | JISX0201 (8-bit encoded character set) | Half duplex | Start-stop synchronization | Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value | Surface mounting, surface connection | 0.5 | Single phase 3 wire | 120 | 50 or 60 (Unverified products are shared) | 100 | 4,800/9,600/19,200bps (selective settings) | Standard product, (BL type) | 4720-2 | |
A2GA-TLN1r (250A) |
Available upon quote | Terminal cover (standard equipment) | 1 bit (None/Even number/Odd number) Can be selected by communication setting button |
1 bit/2 bit Can be selected using the communication setting button - 2 bits can be set only when there is no parity |
8 bit | 1 bit | RS-485 communication (in-house telegram) | JISX0201 (8-bit encoded character set) | Half duplex | Start-stop synchronization | Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value | Surface mounting, surface connection | 0.9 | Single phase 3 wire | 250 | 50 or 60 (Unverified products are shared) | 100 | 4,800/9,600/19,200bps (selective settings) | Standard product, (BL type) | 4722-2 | |
A2GA-TLN1r (/5A) |
Available upon quote | Terminal cover (standard equipment) | 1 bit (None/Even number/Odd number) Can be selected by communication setting button |
1 bit/2 bit Can be selected using the communication setting button - 2 bits can be set only when there is no parity |
8 bit | 1 bit | RS-485 communication (in-house telegram) | JISX0201 (8-bit encoded character set) | Half duplex | Start-stop synchronization | Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value | Surface mounting, surface connection | 0.3 | Single phase 3 wire | /5 | 50 or 60 (Unverified products are shared) | 100 | 4,800/9,600/19,200bps (selective settings) | Standard product | 4736-1 | |
A3GA-TLN1r (30A) |
Available upon quote | Terminal cover (standard equipment) | 1 bit (None/Even number/Odd number) Can be selected by communication setting button |
1 bit/2 bit Can be selected using the communication setting button - 2 bits can be set only when there is no parity |
8 bit | 1 bit | RS-485 communication (in-house telegram) | JISX0201 (8-bit encoded character set) | Half duplex | Start-stop synchronization | Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value | Surface mounting, surface connection | 0.5 | Three-phase three-wire system | 30 | 50 or 60 (Unverified products are shared) | 100200 | 4,800/9,600/19,200bps (selective settings) | Standard product, (BL type) | 4724-2 | |
A3GA-TLN1r (120A) |
Available upon quote | Terminal cover (standard equipment) | 1 bit (None/Even number/Odd number) Can be selected by communication setting button |
1 bit/2 bit Can be selected using the communication setting button - 2 bits can be set only when there is no parity |
8 bit | 1 bit | RS-485 communication (in-house telegram) | JISX0201 (8-bit encoded character set) | Half duplex | Start-stop synchronization | Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value | Surface mounting, surface connection | 0.5 | Three-phase three-wire system | 120 | 50 or 60 (Unverified products are shared) | 100200 | 4,800/9,600/19,200bps (selective settings) | Standard product, (BL type) | 4726-2 | |
A3GA-TLN1r (250A) |
Available upon quote | Terminal cover (standard equipment) | 1 bit (None/Even number/Odd number) Can be selected by communication setting button |
1 bit/2 bit Can be selected using the communication setting button - 2 bits can be set only when there is no parity |
8 bit | 1 bit | RS-485 communication (in-house telegram) | JISX0201 (8-bit encoded character set) | Half duplex | Start-stop synchronization | Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value | Surface mounting, surface connection | 0.9 | Three-phase three-wire system | 250 | 50 or 60 (Unverified products are shared) | 100200 | 4,800/9,600/19,200bps (selective settings) | Standard product, (BL type) | 4728-2 |
Click on the part number for more information about each product