About This Product

Features

■Equipped with new functions to save labor at construction sites

Equipped with communication function compliant with RS-485. Power meter readings can be output using RS-485 communication (in-house telegram). ・All certifications can be obtained -Weight value display can be switched in 4 directions using the LCD display setting button ・Added display backup function, allowing guideline value to be displayed even during power outage ・Infrared communication is standard equipment, and the contact communication port allows reading of instrument settings and measurement data (optional infrared communication device required) ・Record 30-minute values ​​for 44 days and 1-minute values ​​for 35 hours. ・Supports bidirectional measurement, allowing one device to measure both the consumption side and the generation side. *For bidirectional (forward and reverse), the “r” at the end of the model name symbol can be removed. *Other product numbers are available.

  • Product

    Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1r

Share this product


760+ people viewing

Last viewed: 1 hour ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1r

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Communication items Communication interface Communication method Communication interface Communication code Communication interface synchronization method Communication interface Mass (kg) Phase wire system Rated current (A) Rated voltage (V) Rated frequency (Hz) Type approval number (No. ~) Installation/connection method Transmission speed Type Character configuration Parity bit Character configuration data bit Character configuration Stop bit Character configuration start bit Accessories
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1r-Part Number-A1GA-TLN1r (30A)

A1GA-TLN1r (30A)

Available upon quote

Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value

Half duplex

JISX0201 (8-bit encoded character set)

Start-stop synchronization

RS-485 communication (in-house telegram)

0.4

Single phase 2 wire

30

100200240

50 or 60 (Unverified products are shared)

4714-2

Surface mounting, surface connection

4,800/9,600/19,200bps (selective settings)

Standard product, (BL type)

1 bit (None/Even number/Odd number) Can be selected by communication setting button

8 bit

1 bit/2 bit
Can be selected using the communication setting button - 2 bits can be set only when there is no parity

1 bit

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1r-Part Number-A1GA-TLN1r (120A)

A1GA-TLN1r (120A)

Available upon quote

Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value

Half duplex

JISX0201 (8-bit encoded character set)

Start-stop synchronization

RS-485 communication (in-house telegram)

0.4

Single phase 2 wire

120

100200240

50 or 60 (Unverified products are shared)

4716-2

Surface mounting, surface connection

4,800/9,600/19,200bps (selective settings)

Standard product, (BL type)

1 bit (None/Even number/Odd number) Can be selected by communication setting button

8 bit

1 bit/2 bit
Can be selected using the communication setting button - 2 bits can be set only when there is no parity

1 bit

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1r-Part Number-A1GA-TLN1r (/5A)

A1GA-TLN1r (/5A)

Available upon quote

Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value

Half duplex

JISX0201 (8-bit encoded character set)

Start-stop synchronization

RS-485 communication (in-house telegram)

0.3

Single phase 2 wire

/5

/100, 100, 200, 240

50 or 60 (Unverified products are shared)

4734-1

Surface mounting, surface connection

4,800/9,600/19,200bps (selective settings)

Standard product

1 bit (None/Even number/Odd number) Can be selected by communication setting button

8 bit

1 bit/2 bit
Can be selected using the communication setting button - 2 bits can be set only when there is no parity

1 bit

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1r-Part Number-A2GA-TLN1r (30A)

A2GA-TLN1r (30A)

Available upon quote

Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value

Half duplex

JISX0201 (8-bit encoded character set)

Start-stop synchronization

RS-485 communication (in-house telegram)

0.5

Single phase 3 wire

30

100

50 or 60 (Unverified products are shared)

4718-2

Surface mounting, surface connection

4,800/9,600/19,200bps (selective settings)

Standard product, (BL type)

1 bit (None/Even number/Odd number) Can be selected by communication setting button

8 bit

1 bit/2 bit
Can be selected using the communication setting button - 2 bits can be set only when there is no parity

1 bit

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1r-Part Number-A2GA-TLN1r (120A)

A2GA-TLN1r (120A)

Available upon quote

Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value

Half duplex

JISX0201 (8-bit encoded character set)

Start-stop synchronization

RS-485 communication (in-house telegram)

0.5

Single phase 3 wire

120

100

50 or 60 (Unverified products are shared)

4720-2

Surface mounting, surface connection

4,800/9,600/19,200bps (selective settings)

Standard product, (BL type)

1 bit (None/Even number/Odd number) Can be selected by communication setting button

8 bit

1 bit/2 bit
Can be selected using the communication setting button - 2 bits can be set only when there is no parity

1 bit

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1r-Part Number-A2GA-TLN1r (250A)

A2GA-TLN1r (250A)

Available upon quote

Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value

Half duplex

JISX0201 (8-bit encoded character set)

Start-stop synchronization

RS-485 communication (in-house telegram)

0.9

Single phase 3 wire

250

100

50 or 60 (Unverified products are shared)

4722-2

Surface mounting, surface connection

4,800/9,600/19,200bps (selective settings)

Standard product, (BL type)

1 bit (None/Even number/Odd number) Can be selected by communication setting button

8 bit

1 bit/2 bit
Can be selected using the communication setting button - 2 bits can be set only when there is no parity

1 bit

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1r-Part Number-A2GA-TLN1r (/5A)

A2GA-TLN1r (/5A)

Available upon quote

Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value

Half duplex

JISX0201 (8-bit encoded character set)

Start-stop synchronization

RS-485 communication (in-house telegram)

0.3

Single phase 3 wire

/5

100

50 or 60 (Unverified products are shared)

4736-1

Surface mounting, surface connection

4,800/9,600/19,200bps (selective settings)

Standard product

1 bit (None/Even number/Odd number) Can be selected by communication setting button

8 bit

1 bit/2 bit
Can be selected using the communication setting button - 2 bits can be set only when there is no parity

1 bit

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1r-Part Number-A3GA-TLN1r (30A)

A3GA-TLN1r (30A)

Available upon quote

Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value

Half duplex

JISX0201 (8-bit encoded character set)

Start-stop synchronization

RS-485 communication (in-house telegram)

0.5

Three-phase three-wire system

30

100200

50 or 60 (Unverified products are shared)

4724-2

Surface mounting, surface connection

4,800/9,600/19,200bps (selective settings)

Standard product, (BL type)

1 bit (None/Even number/Odd number) Can be selected by communication setting button

8 bit

1 bit/2 bit
Can be selected using the communication setting button - 2 bits can be set only when there is no parity

1 bit

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1r-Part Number-A3GA-TLN1r (120A)

A3GA-TLN1r (120A)

Available upon quote

Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value

Half duplex

JISX0201 (8-bit encoded character set)

Start-stop synchronization

RS-485 communication (in-house telegram)

0.5

Three-phase three-wire system

120

100200

50 or 60 (Unverified products are shared)

4726-2

Surface mounting, surface connection

4,800/9,600/19,200bps (selective settings)

Standard product, (BL type)

1 bit (None/Even number/Odd number) Can be selected by communication setting button

8 bit

1 bit/2 bit
Can be selected using the communication setting button - 2 bits can be set only when there is no parity

1 bit

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN1r, A2GA-TLN1r, A3GA-TLN1r-Part Number-A3GA-TLN1r (250A)

A3GA-TLN1r (250A)

Available upon quote

Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value

Half duplex

JISX0201 (8-bit encoded character set)

Start-stop synchronization

RS-485 communication (in-house telegram)

0.9

Three-phase three-wire system

250

100200

50 or 60 (Unverified products are shared)

4728-2

Surface mounting, surface connection

4,800/9,600/19,200bps (selective settings)

Standard product, (BL type)

1 bit (None/Even number/Odd number) Can be selected by communication setting button

8 bit

1 bit/2 bit
Can be selected using the communication setting button - 2 bits can be set only when there is no parity

1 bit

Terminal cover (standard equipment)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Watt-hour Meters Products

Other products of Osaki Electric Industry Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Osaki Electric Industry Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

22.6hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree