Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r-A1GA-TLN2r (30A)
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r-Osaki Electric Industry Co., Ltd.

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r
Osaki Electric Industry Co., Ltd.


About This Product

■Features Equipped with new functions to save labor at construction sites ・All certifications can be obtained -Weight value display can be switched in 4 directions using the LCD display setting button ・Added display backup function, allowing guideline value to be displayed even during power outage ・Infrared communication is standard equipment, and the contact communication port allows reading of instrument settings and measurement data (optional infrared communication device required) ・Record 30-minute values ​​for 44 days and 1-minute values ​​for 35 hours. - Possible to output electricity meter readings ・Supports bidirectional measurement, allowing one device to measure both the consumption side and the generation side ■Applications It is ideal not only for billing purposes using automatic meter reading systems, but also for energy saving measures. *About the model name: If it is bidirectional (forward or reverse direction), the “r” at the end of the model name symbol can be removed. *Other product numbers are available.

  • Product

    Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r

Share this product


410+ people viewing

Last viewed: 7 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accessories Character configuration Parity bit Character configuration Stop bit Character configuration data bit Character configuration start bit Communication code Communication interface Communication items Communication method Equipment symbol External dimensions Installation/connection method Mass Phase wire system Rated current (A) Rated frequency (Hz) Rated voltage (V) Synchronization method Transmission speed Type Type approval number (No. ~)
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r-Part Number-A1GA-TLN2r (30A)

A1GA-TLN2r (30A)

Available upon quote Terminal cover (standard equipment) 1 bit (even number) 1 bit 7 bit 1 bit JIS X 0201 (JIS7 unit code for Roman characters) Current loop Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value Half duplex, polling N2 100 (W) ×96 (H) ×64 (D) Surface mounting, surface connection Approximately 0.5kg Single phase 2 wire 30 50 or 60 (Unverified products are shared) 100200240 Start-stop synchronization 1,200bps Standard product, BL 4714
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r-Part Number-A1GA-TLN2r (120A)

A1GA-TLN2r (120A)

Available upon quote Terminal cover (standard equipment) 1 bit (even number) 1 bit 7 bit 1 bit JIS X 0201 (JIS7 unit code for Roman characters) Current loop Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value Half duplex, polling N2 100 (W) ×96 (H) ×64 (D) Surface mounting, surface connection Approximately 0.5kg Single phase 2 wire 120 50 or 60 (Unverified products are shared) 100200240 Start-stop synchronization 1,200bps Standard product, BL 4716
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r-Part Number-A1GA-TLN2r (/5A)

A1GA-TLN2r (/5A)

Available upon quote Terminal cover (standard equipment) 1 bit (even number) 1 bit 7 bit 1 bit JIS X 0201 (JIS7 unit code for Roman characters) Current loop Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value Half duplex, polling N2 100 (W) ×96 (H) ×64.2 (D) Surface mounting, surface connection Approximately 0.3kg Single phase 2 wire /5 50 or 60 (Unverified products are shared) /110, 100, 200, 240 Start-stop synchronization 1,200bps Standard product 4734
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r-Part Number-A2GA-TLN2r (30A)

A2GA-TLN2r (30A)

Available upon quote Terminal cover (standard equipment) 1 bit (even number) 1 bit 7 bit 1 bit JIS X 0201 (JIS7 unit code for Roman characters) Current loop Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value Half duplex, polling N2 100 (W) ×96 (H) ×64 (D) Surface mounting, surface connection Approximately 0.5kg Single phase 3 wire 30 50 or 60 (Unverified products are shared) 100 Start-stop synchronization 1,200bps Standard product, BL 4718
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r-Part Number-A2GA-TLN2r (120A)

A2GA-TLN2r (120A)

Available upon quote Terminal cover (standard equipment) 1 bit (even number) 1 bit 7 bit 1 bit JIS X 0201 (JIS7 unit code for Roman characters) Current loop Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value Half duplex, polling N2 100 (W) ×96 (H) ×64 (D) Surface mounting, surface connection Approximately 0.5kg Single phase 3 wire 120 50 or 60 (Unverified products are shared) 100 Start-stop synchronization 1,200bps Standard product, BL 4720
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r-Part Number-A2GA-TLN2r (250A)

A2GA-TLN2r (250A)

Available upon quote Terminal cover (standard equipment) 1 bit (even number) 1 bit 7 bit 1 bit JIS X 0201 (JIS7 unit code for Roman characters) Current loop Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value Half duplex, polling N2 120 (W) ×120 (H) ×65 (D) Surface mounting, surface connection Approximately 0.9kg Single phase 3 wire 250 50 or 60 (Unverified products are shared) 100 Start-stop synchronization 1,200bps Standard product, BL 4722
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r-Part Number-A2GA-TLN2r (/5A)

A2GA-TLN2r (/5A)

Available upon quote Terminal cover (standard equipment) 1 bit (even number) 1 bit 7 bit 1 bit JIS X 0201 (JIS7 unit code for Roman characters) Current loop Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value Half duplex, polling N2 100 (W) ×96 (H) ×64.2 (D) Surface mounting, surface connection Approximately 0.3kg Single phase 3 wire /5 50 or 60 (Unverified products are shared) 100 Start-stop synchronization 1,200bps Standard product 4736
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r-Part Number-A3GA-TLN2r (30A)

A3GA-TLN2r (30A)

Available upon quote Terminal cover (standard equipment) 1 bit (even number) 1 bit 7 bit 1 bit JIS X 0201 (JIS7 unit code for Roman characters) Current loop Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value Half duplex, polling N2 100 (W) ×96 (H) ×64 (D) Surface mounting, surface connection Approximately 0.5kg Three-phase three-wire system 30 50 or 60 (Unverified products are shared) 100200 Start-stop synchronization 1,200bps Standard product, BL 4724
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r-Part Number-A3GA-TLN2r (120A)

A3GA-TLN2r (120A)

Available upon quote Terminal cover (standard equipment) 1 bit (even number) 1 bit 7 bit 1 bit JIS X 0201 (JIS7 unit code for Roman characters) Current loop Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value Half duplex, polling N2 100 (W) ×96 (H) ×64 (D) Surface mounting, surface connection Approximately 0.5kg Three-phase three-wire system 120 50 or 60 (Unverified products are shared) 100200 Start-stop synchronization 1,200bps Standard product, BL 4726
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-TLN2r, A2GA-TLN2r, A3GA-TLN2r-Part Number-A3GA-TLN2r (250A)

A3GA-TLN2r (250A)

Available upon quote Terminal cover (standard equipment) 1 bit (even number) 1 bit 7 bit 1 bit JIS X 0201 (JIS7 unit code for Roman characters) Current loop Active energy (forward flow/reverse flow), instantaneous active power, power factor, current, voltage, 30-minute value, 1-minute value Half duplex, polling N2 120 (W) ×120 (H) ×65 (D) Surface mounting, surface connection Approximately 0.9kg Three-phase three-wire system 250 50 or 60 (Unverified products are shared) 100200 Start-stop synchronization 1,200bps Standard product, BL 4728

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Osaki Electric Industry Co., Ltd.


View more products of Osaki Electric Industry Co., Ltd.

About Company Handling This Product