Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31-A1GA-RLS31 (30A)
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31-Osaki Electric Industry Co., Ltd.

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31
Osaki Electric Industry Co., Ltd.

Osaki Electric Industry Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

22.6hours

Relatively Fast Response


About This Product

■Features

Equipped with new functions to save labor at construction sites ・All certifications can be obtained -Weight value display can be switched in 4 directions using the LCD display setting button ・Added display backup function, allowing guideline value display even during power outage ・Infrared communication is standard equipment, and the contact communication port allows reading of instrument settings and measurement data (optional infrared communication device required)

■Applications

It is ideal not only for billing purposes using automatic meter reading systems, but also for energy saving measures. *BL: Lower power supply type is made to order. *Other product numbers are available.

  • Product

    Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31

Share this product


1170+ people viewing

Last viewed: 10 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Mass Different wire type Phase wire system Polarity Rated current (A) Rated voltage (V) Rated frequency (Hz) External dimensions Type approval number (No. ~) Installation/connection method Output method Alternating or directing Pulse current (mA) Pulse voltage (V) Pulse capacity Pulse output Pulse width Pulse output Pulse constant Type On resistance (Ω) Accessories
Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31-Part Number-A1GA-RLS31 (30A)

A1GA-RLS31 (30A)

Available upon quote

Approximately 0.5kg

2 wires

Single phase 2 wire

None

30

100200240

50 or 60 (Unverified products are shared)

100 (W) ×96 (H) ×64 (D)

4714-1

Surface mounting, surface connection

Transmission pulse (1) CA-CB No-voltage non-contact (Photomos relay, a contact)

Alternating or directing

100DC or 70AC or less

175DC or 120AC or less

10VA or less

Select from 120, 240, 520, 820, 1,020ms
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Select from 1/10, 1, 10, 100pulse/kWh
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Standard product, BL

50 or less

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31-Part Number-A1GA-RLS31 (120A)

A1GA-RLS31 (120A)

Available upon quote

Approximately 0.5kg

2 wires

Single phase 2 wire

None

120

100200240

50 or 60 (Unverified products are shared)

100 (W) ×96 (H) ×64 (D)

4716-1

Surface mounting, surface connection

Transmission pulse (1) CA-CB No-voltage non-contact (Photomos relay, a contact)

Alternating or directing

100DC or 70AC or less

175DC or 120AC or less

10VA or less

Select from 120, 240, 520, 820, 1,020ms
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Select from 1/10, 1, 10, 100pulse/kWh
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Standard product, BL

50 or less

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31-Part Number-A1GA-RLS31 (/5A)

A1GA-RLS31 (/5A)

Available upon quote

Approximately 0.3kg

2 wires

Single phase 2 wire

None

/5

/110, 100, 200, 240

50 or 60 (Unverified products are shared)

100 (W) ×96 (H) ×64.2 (D)

4735

Surface mounting, surface connection

Transmission pulse (1) CA-CB No-voltage non-contact (Photomos relay, a contact)

Alternating or directing

100DC or 70AC or less

175DC or 120AC or less

10VA or less

10^n: Select from 120, 240, 520, 820, 1,020ms
Unique: 240ms

10^n: Select from 1/10/multiplication factor, 1/multiplication factor, 10/multiplication factor, 100/multiplication factor pulse/kWh
Specific: 4,000pulse/kWh (/110, 100V), 2,000pulse/kWh (200, 240V)

Standard product

50 or less

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31-Part Number-A2GA-RLS31 (30A)

A2GA-RLS31 (30A)

Available upon quote

Approximately 0.5kg

2 wires

Single phase 3 wire

None

30

100

50 or 60 (Unverified products are shared)

100 (W) ×96 (H) ×64 (D)

4718-1

Surface mounting, surface connection

Transmission pulse (1) CA-CB No-voltage non-contact (Photomos relay, a contact)

Alternating or directing

100DC or 70AC or less

175DC or 120AC or less

10VA or less

Select from 120, 240, 520, 820, 1,020ms
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Select from 1/10, 1, 10, 100pulse/kWh
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Standard product, BL

50 or less

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31-Part Number-A2GA-RLS31 (120A)

A2GA-RLS31 (120A)

Available upon quote

Approximately 0.5kg

2 wires

Single phase 3 wire

None

120

100

50 or 60 (Unverified products are shared)

100 (W) ×96 (H) ×64 (D)

4720-1

Surface mounting, surface connection

Transmission pulse (1) CA-CB No-voltage non-contact (Photomos relay, a contact)

Alternating or directing

100DC or 70AC or less

175DC or 120AC or less

10VA or less

Select from 120, 240, 520, 820, 1,020ms
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Select from 1/10, 1, 10, 100pulse/kWh
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Standard product, BL

50 or less

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31-Part Number-A2GA-RLS31 (250A)

A2GA-RLS31 (250A)

Available upon quote

Approximately 0.9kg

2 wires

Single phase 3 wire

None

250

100

50 or 60 (Unverified products are shared)

120 (W) ×120 (H) ×65 (D)

4722-1

Surface mounting, surface connection

Transmission pulse (1) CA-CB No-voltage non-contact (Photomos relay, a contact)

Alternating or directing

100DC or 70AC or less

175DC or 120AC or less

10VA or less

Select from 120, 240, 520, 820, 1,020ms
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Select from 1/10, 1, 10, 100pulse/kWh
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Standard product, BL

50 or less

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31-Part Number-A2GA-RLS31 (/5A)

A2GA-RLS31 (/5A)

Available upon quote

Approximately 0.3kg

2 wires

Single phase 3 wire

None

/5

100

50 or 60 (Unverified products are shared)

100 (W) ×96 (H) ×64.2 (D)

4737

Surface mounting, surface connection

Transmission pulse (1) CA-CB No-voltage non-contact (Photomos relay, a contact)

Alternating or directing

100DC or 70AC or less

175DC or 120AC or less

10VA or less

10^n: Select from 120, 240, 520, 820, 1,020ms
Unique: 240ms

10^n: Select from 1/10/multiplication factor, 1/multiplication factor, 10/multiplication factor, 100/multiplication factor pulse/kWh
Specific: 2,000pulse/kWh

Standard product

50 or less

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31-Part Number-A3GA-RLS31 (30A)

A3GA-RLS31 (30A)

Available upon quote

Approximately 0.5kg

2 wires

Three-phase three-wire system

None

30

100200

50 or 60 (Unverified products are shared)

100 (W) ×96 (H) ×64 (D)

4724-1

Surface mounting, surface connection

Transmission pulse (1) CA-CB No-voltage non-contact (Photomos relay, a contact)

Alternating or directing

100DC or 70AC or less

175DC or 120AC or less

10VA or less

Select from 120, 240, 520, 820, 1,020ms
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Select from 1/10, 1, 10, 100pulse/kWh
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Standard product, BL

50 or less

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31-Part Number-A3GA-RLS31 (120A)

A3GA-RLS31 (120A)

Available upon quote

Approximately 0.5kg

2 wires

Three-phase three-wire system

None

120

100200

50 or 60 (Unverified products are shared)

100 (W) ×96 (H) ×64 (D)

4726-1

Surface mounting, surface connection

Transmission pulse (1) CA-CB No-voltage non-contact (Photomos relay, a contact)

Alternating or directing

100DC or 70AC or less

175DC or 120AC or less

10VA or less

Select from 120, 240, 520, 820, 1,020ms
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Select from 1/10, 1, 10, 100pulse/kWh
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Standard product, BL

50 or less

Terminal cover (standard equipment)

Energy meter Compact EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1GA-RLS31, A2GA-RLS31, A3GA-RLS31-Part Number-A3GA-RLS31 (250A)

A3GA-RLS31 (250A)

Available upon quote

Approximately 0.9kg

2 wires

Three-phase three-wire system

None

250

100200

50 or 60 (Unverified products are shared)

120 (W) ×120 (H) ×65 (D)

4728-1

Surface mounting, surface connection

Transmission pulse (1) CA-CB No-voltage non-contact (Photomos relay, a contact)

Alternating or directing

100DC or 70AC or less

175DC or 120AC or less

10VA or less

Select from 120, 240, 520, 820, 1,020ms
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Select from 1/10, 1, 10, 100pulse/kWh
*Even after installation, the pulse width and pulse constant can be changed from the front of the instrument. Please note that some combinations cannot be set depending on the selection of pulse width and pulse constant.

Standard product, BL

50 or less

Terminal cover (standard equipment)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Watt-hour Meters Products

Other products of Osaki Electric Industry Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Osaki Electric Industry Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

22.6hrs

  • Japan