About This Product

■Features

-Compliant with the Measurement Act. - The guideline value can be displayed to two decimal places, making it easy to check operation under actual load. - Some instruments have type approval from the Japan Electric Meter Inspection Institute. (See the specifications column for compatible products) - With the addition of a display backup function, weighing can be displayed even during a power outage. This product is a type with current loop communication function.

  • Product

    Energy meter Built-in EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1D-RLN2SV, A2D-RLN2SV, A3D-RLN2SV

Share this product


430+ people viewing

Last viewed: 1 hour ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

3 Models of Energy meter Built-in EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1D-RLN2SV, A2D-RLN2SV, A3D-RLN2SV

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Current circuit apparent power (VA) Voltage circuit apparent power (VA) Mass (g) Instrument constant (pulse/kWs) 220V Instrument constant (pulse/kWs) 200V Instrument constant (pulse/kWs) 100V Instrument constant (pulse/kWs) /110V Terminal cover Phase wire system Rated current (A) Rated voltage (V) Rated frequency (Hz) Type approval number Installation/connection method Pulse width specific (1) Pulse width Front metering pulse Pulse width 10^n Pulse constant specific (1) /5A Pulse constant 10^n (pulse/kWh) S27 type transmitter specifications Wire type S27 type transmitter specifications polarity S27 type transmitter specifications output method S27 type transmitter specifications AC/DC S27 type transmitter specifications Pulse current S27 type transmitter specifications pulse voltage S27 type transmitter specifications pulse capacity S27 type transmitter specifications On-resistance (Ω) Instrument constant (pulse/kWs) 240V
Energy meter Built-in EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1D-RLN2SV, A2D-RLN2SV, A3D-RLN2SV-Part Number-A1D-RLN2SV

A1D-RLN2SV

Available upon quote

1S-1L: 0.08 or less

P1-P2: 1.09 or less

Approximately 450

-

1,000

2,000

2,000

Standard equipment

Single phase 2 wire

/5

100, /110, 200, 240

50 or 60

No. 4596-1

Embedded mounting/rear connection

240±15msec (fixed)

21μsec or more

Select one from 120, 240, 520, 820, 1020±15msec

100V, /110V: 4,000 pulse/kWh
200V, 240V: 2,000 pulse/kWh

1/10/ (multiplication factor), 1/ (multiplication factor), 10/ (multiplication factor), 100/ (multiplication factor)
(pulse/kWh, pulse/kvarh)

2 wires

None

Transmission pulse (1) C1A-C1B No-voltage a contact (photomos relay)
Transmission pulse (2) C2A-C2B No-voltage a contact (Photomos relay)

Alternating or directing

0.1ADC or 0.07AAC or less

175VDC or 120VAC or less

10VA or less

50 or less

750

Energy meter Built-in EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1D-RLN2SV, A2D-RLN2SV, A3D-RLN2SV-Part Number-A2D-RLN2SV

A2D-RLN2SV

Available upon quote

1S-1L, 3S-3L: 0.08 or less

P1-P2: 0.75 or less
P3-P2: 0.02 or less

Approximately 460

- -

1,000

-

Standard equipment

Single phase 3 wire

/5

100

50 or 60

No. 4597-1

Embedded mounting/rear connection

240±15msec (fixed)

21μsec or more

Select one from 120, 240, 520, 820, 1020±15msec

2,000 pulses/kWh

1/10/ (multiplication factor), 1/ (multiplication factor), 10/ (multiplication factor), 100/ (multiplication factor)
(pulse/kWh, pulse/kvarh)

2 wires

None

Transmission pulse (1) C1A-C1B No-voltage a contact (photomos relay)
Transmission pulse (2) C2A-C2B No-voltage a contact (Photomos relay)

Alternating or directing

0.1ADC or 0.07AAC or less

175VDC or 120VAC or less

10VA or less

50 or less

-
Energy meter Built-in EM Single-phase 2-wire/Single-phase 3-wire/Three-phase 3-wire A1D-RLN2SV, A2D-RLN2SV, A3D-RLN2SV-Part Number-A3D-RLN2SV

A3D-RLN2SV

Available upon quote

1S-1L, 3S-3L: 0.08 or less

P1-P2: 0.99 or less
P3-P2: 0.07 or less

Approximately 460

500

500

1,000

1,000

Standard equipment

Three-phase three-wire system

/5

100, /110, 200, (220)

50 or 60

No. 4598-1

Embedded mounting/rear connection

240±15msec (fixed)

21μsec or more

Select one from 120, 240, 520, 820, 1020±15msec

100V, /110V: 2,000 pulse/kWh
200V, 240V: 1,000 pulse/kWh

1/10/ (multiplication factor), 1/ (multiplication factor), 10/ (multiplication factor), 100/ (multiplication factor)
(pulse/kWh, pulse/kvarh)

2 wires

None

Transmission pulse (1) C1A-C1B No-voltage a contact (photomos relay)
Transmission pulse (2) C2A-C2B No-voltage a contact (Photomos relay)

Alternating or directing

0.1ADC or 0.07AAC or less

175VDC or 120VAC or less

10VA or less

50 or less

-

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Watt-hour Meters Products

Other products of Osaki Electric Industry Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Osaki Electric Industry Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

22.6hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree