All Categories

History

High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-SCKR6A-025-200-B
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Dyadic Systems Co., Ltd.

High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series
Dyadic Systems Co., Ltd.

Dyadic Systems Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

8.6hours

Fast Response


About This Product

■Since the initial settings have been completed, you can use it immediately.

・Multi-point positioning operation, pitch feeding operation, and pressing operation are possible. ・Movement speed, acceleration/deceleration, etc. can be set.

■High rigidity with iron base

Uses THK steel base KR45□□ A/C series

■Equal load in 4 directions

Each ball row is arranged so that it has the same rated load in four directions (radial direction, reverse radial direction, and lateral direction).

■One unit can be used in a variety of ways depending on the purpose.

・Used in parallel connection ・Used with serial connection ・Used with pneumatic (air) compatible functions ・Used for self-control function ・Compatible with fieldbus - Operates with a switch *Other product numbers are available.

  • Product

    High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series

Share this product


350+ people viewing

Last viewed: 14 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power supply Allowable load moment (Nm) / (kgfcm) Repeated positioning accuracy (mm) Maximum horizontal payload (kg) Maximum speed (mm/s): Typical value at25℃ Maximum thrust (N) / (kgf): Typical value Maximum thrust in push mode (N) / (kgf) typ value Maximum vertical payload (kg) Input/output signal Parallel output signal Output current Input/output signal Parallel output signal Signal name Input/output signal Parallel input signal Input current Input/output signal Parallel input signal Signal name Input/output signal Serial signal Protection function Storage temperature Operating temperature Usage/storage humidity Number of positioning points Lost motion (mm) Ball screw lead (mm) Stroke (mm) Cylinder body weight (kg) Servo amplifier weight (kg)
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-200-B

SCKR6A-025-200-B

Available upon quote

DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)

Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000

±0.04

60

600

300/30

210/21

4/15 (when using external regeneration unit)

Max 30mA/port
(Open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Max 4mA/port
(Please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when using serial control)

0.1 or less

20 (Resolution: 0.025mm)

200

7.2

0.5

High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-300-B

SCKR6A-025-300-B

Available upon quote

DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)

Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000

±0.04

60

600

300/30

210/21

4/15 (when using external regeneration unit)

Max 30mA/port
(Open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Max 4mA/port
(Please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when using serial control)

0.1 or less

20 (Resolution: 0.025mm)

300

8.3

0.5

High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-400-B

SCKR6A-025-400-B

Available upon quote

DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)

Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000

±0.04

60

600

300/30

210/21

4/15 (when using external regeneration unit)

Max 30mA/port
(Open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Max 4mA/port
(Please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when using serial control)

0.1 or less

20 (Resolution: 0.025mm)

400

9.4

0.5

High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-500-B

SCKR6A-025-500-B

Available upon quote

DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)

Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000

±0.04

60

600

300/30

210/21

4/15 (when using external regeneration unit)

Max 30mA/port
(Open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Max 4mA/port
(Please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when using serial control)

0.1 or less

20 (Resolution: 0.025mm)

500

10.5

0.5

High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-600-B

SCKR6A-025-600-B

Available upon quote

DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)

Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000

±0.04

60

600

300/30

210/21

4/15 (when using external regeneration unit)

Max 30mA/port
(Open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Max 4mA/port
(Please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when using serial control)

0.1 or less

20 (Resolution: 0.025mm)

600

11.6

0.5

High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-700-B

SCKR6A-025-700-B

Available upon quote

DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)

Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000

±0.04

60

600

300/30

210/21

4/15 (when using external regeneration unit)

Max 30mA/port
(Open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Max 4mA/port
(Please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when using serial control)

0.1 or less

20 (Resolution: 0.025mm)

700

12.7

0.5

High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-800-B

SCKR6A-025-800-B

Available upon quote

DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)

Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000

±0.04

60

600

300/30

210/21

4/15 (when using external regeneration unit)

Max 30mA/port
(Open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Max 4mA/port
(Please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when using serial control)

0.1 or less

20 (Resolution: 0.025mm)

800

13.8

0.5

High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-900-B

SCKR6A-025-900-B

Available upon quote

DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)

Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000

±0.04

60

600

300/30

210/21

4/15 (when using external regeneration unit)

Max 30mA/port
(Open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Max 4mA/port
(Please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when using serial control)

0.1 or less

20 (Resolution: 0.025mm)

900

14.9

0.5

High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-1000-B

SCKR6A-025-1000-B

Available upon quote

DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)

Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000

±0.04

60

510

300/30

210/21

4/15 (when using external regeneration unit)

Max 30mA/port
(Open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Max 4mA/port
(Please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when using serial control)

0.1 or less

20 (Resolution: 0.025mm)

1,000

16

0.5

High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-1100-B

SCKR6A-025-1100-B

Available upon quote

DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)

Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000

±0.04

60

430

300/30

210/21

4/15 (when using external regeneration unit)

Max 30mA/port
(Open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Max 4mA/port
(Please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when using serial control)

0.1 or less

20 (Resolution: 0.025mm)

1,100

17.1

0.5

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Cylinders Products

Other products of Dyadic Systems Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Dyadic Systems Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

8.6hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree