High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-SCKR6A-025-200-B
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Dyadic Systems Co., Ltd.

High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series
Dyadic Systems Co., Ltd.


About This Product

■Since the initial settings have been completed, you can use it immediately. ・Multi-point positioning operation, pitch feeding operation, and pressing operation are possible. ・Movement speed, acceleration/deceleration, etc. can be set. ■High rigidity with iron base Uses THK steel base KR45□□ A/C series ■Equal load in 4 directions Each ball row is arranged so that it has the same rated load in four directions (radial direction, reverse radial direction, and lateral direction). ■One unit can be used in a variety of ways depending on the purpose. ・Used in parallel connection ・Used with serial connection ・Used with pneumatic (air) compatible functions ・Used for self-control function ・Compatible with fieldbus - Operates with a switch *Other product numbers are available.

  • Product

    High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series

Share this product


230+ people viewing

Last viewed: 8 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Allowable load moment (Nm) / (kgfcm) Ball screw lead (mm) Cylinder body weight (kg) Input/output signal Parallel input signal Input current Input/output signal Parallel input signal Signal name Input/output signal Parallel output signal Output current Input/output signal Parallel output signal Signal name Input/output signal Serial signal Lost motion (mm) Maximum horizontal payload (kg) Maximum speed (mm/s): Typical value at25℃ Maximum thrust (N) / (kgf): Typical value Maximum thrust in push mode (N) / (kgf) typ value Maximum vertical payload (kg) Number of positioning points Operating temperature Power supply Protection function Repeated positioning accuracy (mm) Servo amplifier weight (kg) Storage temperature Stroke (mm) Usage/storage humidity
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-200-B

SCKR6A-025-200-B

Available upon quote Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000
20 (Resolution: 0.025mm) 7.2 Max 4mA/port
(Please connect with sink type output circuit)
DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)
Max 30mA/port
(Open collector output)
DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)
Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-
0.1 or less 60 600 300/30 210/21 4/15 (when using external regeneration unit) 16 (However, unlimited when using serial control) 0~40℃ DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)
Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error
±0.04 0.5 -20~60℃ 200 ≦ 90% RH, but no condensation
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-300-B

SCKR6A-025-300-B

Available upon quote Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000
20 (Resolution: 0.025mm) 8.3 Max 4mA/port
(Please connect with sink type output circuit)
DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)
Max 30mA/port
(Open collector output)
DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)
Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-
0.1 or less 60 600 300/30 210/21 4/15 (when using external regeneration unit) 16 (However, unlimited when using serial control) 0~40℃ DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)
Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error
±0.04 0.5 -20~60℃ 300 ≦ 90% RH, but no condensation
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-400-B

SCKR6A-025-400-B

Available upon quote Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000
20 (Resolution: 0.025mm) 9.4 Max 4mA/port
(Please connect with sink type output circuit)
DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)
Max 30mA/port
(Open collector output)
DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)
Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-
0.1 or less 60 600 300/30 210/21 4/15 (when using external regeneration unit) 16 (However, unlimited when using serial control) 0~40℃ DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)
Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error
±0.04 0.5 -20~60℃ 400 ≦ 90% RH, but no condensation
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-500-B

SCKR6A-025-500-B

Available upon quote Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000
20 (Resolution: 0.025mm) 10.5 Max 4mA/port
(Please connect with sink type output circuit)
DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)
Max 30mA/port
(Open collector output)
DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)
Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-
0.1 or less 60 600 300/30 210/21 4/15 (when using external regeneration unit) 16 (However, unlimited when using serial control) 0~40℃ DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)
Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error
±0.04 0.5 -20~60℃ 500 ≦ 90% RH, but no condensation
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-600-B

SCKR6A-025-600-B

Available upon quote Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000
20 (Resolution: 0.025mm) 11.6 Max 4mA/port
(Please connect with sink type output circuit)
DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)
Max 30mA/port
(Open collector output)
DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)
Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-
0.1 or less 60 600 300/30 210/21 4/15 (when using external regeneration unit) 16 (However, unlimited when using serial control) 0~40℃ DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)
Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error
±0.04 0.5 -20~60℃ 600 ≦ 90% RH, but no condensation
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-700-B

SCKR6A-025-700-B

Available upon quote Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000
20 (Resolution: 0.025mm) 12.7 Max 4mA/port
(Please connect with sink type output circuit)
DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)
Max 30mA/port
(Open collector output)
DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)
Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-
0.1 or less 60 600 300/30 210/21 4/15 (when using external regeneration unit) 16 (However, unlimited when using serial control) 0~40℃ DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)
Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error
±0.04 0.5 -20~60℃ 700 ≦ 90% RH, but no condensation
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-800-B

SCKR6A-025-800-B

Available upon quote Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000
20 (Resolution: 0.025mm) 13.8 Max 4mA/port
(Please connect with sink type output circuit)
DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)
Max 30mA/port
(Open collector output)
DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)
Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-
0.1 or less 60 600 300/30 210/21 4/15 (when using external regeneration unit) 16 (However, unlimited when using serial control) 0~40℃ DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)
Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error
±0.04 0.5 -20~60℃ 800 ≦ 90% RH, but no condensation
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-900-B

SCKR6A-025-900-B

Available upon quote Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000
20 (Resolution: 0.025mm) 14.9 Max 4mA/port
(Please connect with sink type output circuit)
DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)
Max 30mA/port
(Open collector output)
DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)
Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-
0.1 or less 60 600 300/30 210/21 4/15 (when using external regeneration unit) 16 (However, unlimited when using serial control) 0~40℃ DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)
Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error
±0.04 0.5 -20~60℃ 900 ≦ 90% RH, but no condensation
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-1000-B

SCKR6A-025-1000-B

Available upon quote Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000
20 (Resolution: 0.025mm) 16 Max 4mA/port
(Please connect with sink type output circuit)
DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)
Max 30mA/port
(Open collector output)
DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)
Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-
0.1 or less 60 510 300/30 210/21 4/15 (when using external regeneration unit) 16 (However, unlimited when using serial control) 0~40℃ DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)
Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error
±0.04 0.5 -20~60℃ 1,000 ≦ 90% RH, but no condensation
High rigidity iron base rodless mechanical cylinder (electric cylinder) SCKR6 series-Part Number-SCKR6A-025-1100-B

SCKR6A-025-1100-B

Available upon quote Mp = 243 / 2,430
My = 243 / 2,430
Mr = 400 / 4,000
20 (Resolution: 0.025mm) 17.1 Max 4mA/port
(Please connect with sink type output circuit)
DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)
Max 30mA/port
(Open collector output)
DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)
Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-
0.1 or less 60 430 300/30 210/21 4/15 (when using external regeneration unit) 16 (However, unlimited when using serial control) 0~40℃ DC24V±10%
(Motor power supply max. 3.0 A, control circuit power supply max. 0.2 A)
Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error
±0.04 0.5 -20~60℃ 1,100 ≦ 90% RH, but no condensation

Click on the part number for more information about each product