All Categories

History

High rigidity rodless cylinder SCLG6 series-SCLG6-030-200-B
High rigidity rodless cylinder SCLG6 series-Dyadic Systems Co., Ltd.

High rigidity rodless cylinder SCLG6 series
Dyadic Systems Co., Ltd.

Dyadic Systems Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

8.6hours

Fast Response


About This Product

■A miniature LM guide is built into the conventional SCLL6 series.

・The SCLG6-030 series has a brake function and battery-less absolute specification as standard. ・The maximum vertical payload of the SCLG6-030 series is 20 kg. ・The maximum horizontal payload of the SCLG6 series is 20 kg.

■Energy-saving, simple, and highly functional compared to air cylinders.

・The maximum number of points that can be set is 16 points. - Positioning operation, pitch feed operation, and pressing operation are possible. - Acceleration/deceleration and movement speed can be set.

■One unit can be used in a variety of ways depending on the purpose.

・Used in parallel connection ・Used with serial connection ・Used with pneumatic (air) compatible functions ・Used for self-control function ・Compatible with fieldbus - Operates with a switch *Other product numbers are available.

  • Product

    High rigidity rodless cylinder SCLG6 series

Share this product


430+ people viewing

Last viewed: 38 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of High rigidity rodless cylinder SCLG6 series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power supply Allowable load moment (Nm) / (kgfcm) Repeated positioning accuracy (mm) Maximum horizontal payload (kg) Maximum speed (mm/s): Typical value at25℃ Maximum thrust (N) / (kgf): Typical value Maximum thrust in push mode (N) / (kgf) typ value Maximum vertical payload (kg) Input/output signal Parallel output signal Output current Input/output signal Parallel output signal Signal name Input/output signal Parallel input signal Input current Input/output signal Parallel input signal Signal name Input/output signal Serial signal Protection function Storage temperature Operating temperature Usage/storage humidity Number of positioning points Lost motion (mm) Stroke (mm) Cylinder weight (kg) Servo amplifier weight (kg)
High rigidity rodless cylinder SCLG6 series-Part Number-SCLG6-030-200-B

SCLG6-030-200-B

Available upon quote

DC24V±10% (Motor power supply max. 3.0A, control circuit power supply max. 0.2A)

Mp=6/60, My=6/60, Mr=10/100

±0.01 (short-time repeatable positioning accuracy)

20

150

300/30.6

280/28.6

20

Maximum 30mA/port (open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Maximum 4mA/port (please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error, encoder disconnection

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when connected via serial)

0.3

200

2.7

0.5

High rigidity rodless cylinder SCLG6 series-Part Number-SCLG6-030-300-B

SCLG6-030-300-B

Available upon quote

DC24V±10% (Motor power supply max. 3.0A, control circuit power supply max. 0.2A)

Mp=6/60, My=6/60, Mr=10/100

±0.01 (short-time repeatable positioning accuracy)

20

150

300/30.6

280/28.6

20

Maximum 30mA/port (open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Maximum 4mA/port (please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error, encoder disconnection

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when connected via serial)

0.3

300

3.7

0.5

High rigidity rodless cylinder SCLG6 series-Part Number-SCLG6-030-400-B

SCLG6-030-400-B

Available upon quote

DC24V±10% (Motor power supply max. 3.0A, control circuit power supply max. 0.2A)

Mp=6/60, My=6/60, Mr=10/100

±0.01 (short-time repeatable positioning accuracy)

20

150

300/30.6

280/28.6

20

Maximum 30mA/port (open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Maximum 4mA/port (please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error, encoder disconnection

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when connected via serial)

0.3

400

4.7

0.5

High rigidity rodless cylinder SCLG6 series-Part Number-SCLG6-030-500-B

SCLG6-030-500-B

Available upon quote

DC24V±10% (Motor power supply max. 3.0A, control circuit power supply max. 0.2A)

Mp=6/60, My=6/60, Mr=10/100

±0.01 (short-time repeatable positioning accuracy)

20

150

300/30.6

280/28.6

20

Maximum 30mA/port (open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Maximum 4mA/port (please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error, encoder disconnection

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when connected via serial)

0.3

500

5.7

0.5

High rigidity rodless cylinder SCLG6 series-Part Number-SCLG6-030-600-B

SCLG6-030-600-B

Available upon quote

DC24V±10% (Motor power supply max. 3.0A, control circuit power supply max. 0.2A)

Mp=6/60, My=6/60, Mr=10/100

±0.01 (short-time repeatable positioning accuracy)

20

150

300/30.6

280/28.6

20

Maximum 30mA/port (open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Maximum 4mA/port (please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error, encoder disconnection

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when connected via serial)

0.3

600

6.7

0.5

High rigidity rodless cylinder SCLG6 series-Part Number-SCLG6-030-700-B

SCLG6-030-700-B

Available upon quote

DC24V±10% (Motor power supply max. 3.0A, control circuit power supply max. 0.2A)

Mp=6/60, My=6/60, Mr=10/100

±0.01 (short-time repeatable positioning accuracy)

20

140

300/30.6

280/28.6

20

Maximum 30mA/port (open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Maximum 4mA/port (please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error, encoder disconnection

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when connected via serial)

0.3

700

7.7

0.5

High rigidity rodless cylinder SCLG6 series-Part Number-SCLG6-030-800-B

SCLG6-030-800-B

Available upon quote

DC24V±10% (Motor power supply max. 3.0A, control circuit power supply max. 0.2A)

Mp=6/60, My=6/60, Mr=10/100

±0.01 (short-time repeatable positioning accuracy)

20

110

300/30.6

280/28.6

20

Maximum 30mA/port (open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Maximum 4mA/port (please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error, encoder disconnection

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when connected via serial)

0.3

800

8.7

0.5

High rigidity rodless cylinder SCLG6 series-Part Number-SCLG6-030-1000-B

SCLG6-030-1000-B

Available upon quote

DC24V±10% (Motor power supply max. 3.0A, control circuit power supply max. 0.2A)

Mp=6/60, My=6/60, Mr=10/100

±0.01 (short-time repeatable positioning accuracy)

20

75

300/30.6

280/28.6

20

Maximum 30mA/port (open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Maximum 4mA/port (please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error, encoder disconnection

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when connected via serial)

0.3

1,000

10.7

0.5

High rigidity rodless cylinder SCLG6 series-Part Number-SCLG6-020-200-B

SCLG6-020-200-B

Available upon quote

DC24V±10% (Motor power supply max. 3.0A, control circuit power supply max. 0.2A)

Mp=6/60, My=6/60, Mr=10/100

±0.01 (short-time repeatable positioning accuracy)

20

300

200/20.4

140/14.2

10

Maximum 30mA/port (open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Maximum 4mA/port (please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error, encoder disconnection

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when connected via serial)

0.3

200

2.7

0.5

High rigidity rodless cylinder SCLG6 series-Part Number-SCLG6-020-300-B

SCLG6-020-300-B

Available upon quote

DC24V±10% (Motor power supply max. 3.0A, control circuit power supply max. 0.2A)

Mp=6/60, My=6/60, Mr=10/100

±0.01 (short-time repeatable positioning accuracy)

20

300

200/20.4

140/14.2

10

Maximum 30mA/port (open collector output)

DC24V system
DI/DO interface (connector PIO)
Positioning complete (PFIN), alarm (ALM),
Zone signal (ZONE),
Home return completed (ZFIN)

Maximum 4mA/port (please connect with sink type output circuit)

DC24V DI/DO interface (connector PIO)
Target position number (4-bit binary: PC1, PC2, PC4, PC8)
Start (CSTR), axis movement interlock (ILK)

Serial interface (connector SIO)
+5V, 5G, TRx+, TRx-

Overspeed, main power overvoltage, regenerative voltage abnormality,
Overload, sensor error, servo error, encoder disconnection

-20~60℃

0~40℃

≦ 90% RH, but no condensation

16 (However, unlimited when connected via serial)

0.3

300

3.7

0.5

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Cylinders Products

Other products of Dyadic Systems Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Dyadic Systems Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

8.6hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree