All Categories

History

Circulation pump controller (continuous circulation) Inkjet reflux pump PWM drive compatible IJCP-01 system-IJCP-01
Circulation pump controller (continuous circulation) Inkjet reflux pump PWM drive compatible IJCP-01 system-Y Drive Co., Ltd.

Circulation pump controller (continuous circulation) Inkjet reflux pump PWM drive compatible IJCP-01 system
Y Drive Co., Ltd.

Y Drive Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

94.6hours


About This Product

■IJCP-01 System basic concept

- Stabilization control of ink pressure inside the head ensures stable ejection at all times. ・Effectively reflux and discharge cleaning liquid inside the head. - More effective than flushing to control the discharge of air remaining inside the head when replacing ink. - Compatible with the diversification of reflux routes, increasing the degree of freedom in reflux, cleaning, discharge, etc. ・Support for small total reflux amount depends on the reflux system, but it is possible to use at least 50cc of ink. ・The temperature of the reflux liquid can be adjusted, and the liquid temperature can be heated from 5 to 50℃ using an external temperature controller in the reservoir tank. - Air bubbles can be removed in the reservoir tank during the temperature of the reflux liquid.

■IJCP-01 System overall configuration

This device consists of the IJCP-01 pump controller, IJCP-01 pump drive section, and head unit, and is used to stably supply ink to the two heads.

■IJCP-01 Pump controller

Controls the IJCP-01 pump driver that supplies ink to the head at the optimal pressure.

■IJCP-01 Pump driver

IJCP-01 This is a driver that can perform PWM control of the following pumps built into this machine by receiving control signals from the pump controller. ・Air pump for generating pressure ・Air pump for pressure generation ・reflux pump

■Head unit

This unit is a mechanism that supplies the appropriate amount of ink required by the head. For this reason, it is necessary to shorten the path as much as possible, so the following parts are placed as short as possible in the head. ・Pressure sensor ・Liquid feeding ink tank ・Ink outflow channel cock ・Liquid receiving ink tank ・Negative pressure sensor ・reflux pump ・Float sensor for reflux pump or manual SW

■IJCP-01 Pump controller

This controller controls each pump. The pressure and negative pressure pumps supply the appropriate amount of ink to the head based on feedback from the pressure sensor and negative pressure sensor. The appropriate feed pressure is set from this controller panel or PC depending on the ink used, etc. The reflux pump is controlled by the pump drive unit using the float sensor in the liquid receiving ink tank or the manual switch.

  • Product

    Circulation pump controller (continuous circulation) Inkjet reflux pump PWM drive compatible IJCP-01 system

Share this product


110+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Circulation pump controller (continuous circulation) Inkjet reflux pump PWM drive compatible IJCP-01 system

Image Part Number Price (excluding tax) Drive voltage Drive frequency Current Voltage resolution Voltage Pressure range Pressure resolution Frequency resolution Interface PWM Duty
Circulation pump controller (continuous circulation) Inkjet reflux pump PWM drive compatible IJCP-01 system-Part Number-IJCP-01

IJCP-01

Available upon quote

0.0V ~ 3.0V (transmission/negative pressure/reflux pump drive control)

10.0KHz~64.0KHz (transmission and negative pressure pump drive control)
10.0Hz~64Hz (reflux pump drive control)

0.2A

12bit (transmission and negative pressure pump drive control)
12.9mV (reflux pump drive control)

AC100V

±99.99kPa (both pressure sensor and negative pressure sensor)

0.01kPa (both pressure sensor and negative pressure sensor)

0.1KHz (transmission and negative pressure pump drive control)
0.1Hz (reflux pump drive control)

Settings from a PC use USB 2.0.

0~95% (Sending and negative pressure/reflux pump drive control)

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Circulating Pumps Products

Other products of Y Drive Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Y Drive Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

94.6hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree