All Categories
History
Product
Airy Technology Particle Counter R (Remote Type) SeriesHandling Company
Particles Plus, Inc.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Weight | Communication/Power | Counting efficiency | Standards/Warranty | Measurement range/number of channels | Maximum measurable concentration | Size | Suction flow rate (per minute) | False counting | Usage/storage environment | Location | User selectable settings | User interface | Memory/Login interval | Pump Vacuum source (required degree of vacuum) | Alarm | Option | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AT-R306 |
Available upon quote |
1.18Kg |
USB, Ethernet, RS485 or RS232-C (optional) /AC100~240V,DC15V2A |
50% ± 20% of the number of PSL standard particles of the corresponding particle size at the minimum measurable particle size, 100% ± 10% at 1.5 times the particle size PSL |
ISO 21501-4, JIS B-9921/1 year after purchase (2 year warranty for semiconductor laser only) |
0.3μm~10.0μm/6 channels |
Counting loss rate within 10%. 30,000,000 pieces/CF (1,060,000 pieces/m3, 1,060,000 pieces/L, 50,000 pieces/second) |
W133xD58xH193 |
2.83L (0.1CF) Automatic flow rate detection with built-in flow controller, P type automatically adjusts flow rate, tube extension within 5m (depending on conditions) |
1 count/60 minutes at minimum measurable particle size |
Operating temperature 5℃~40℃/Storage temperature 0℃~50℃, relative humidity 20%~95% (no condensation) |
500 locations, 20 characters input |
The minimum measurable particle size is fixed. Particle size can be set in 0.01um steps beyond that range. |
Display (4.3inWQVAG color touch screen), icon operation |
45,000 (Can be called at any time on the device screen even during measurement, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Without pump (>38.1cmhg) |
Count, concentration, temperature/humidity (when optional temperature/humidity sensor is installed), red screen display, beep |
Carrying case (AS99015T), temperature and humidity sensor (EE80014A), dedicated thermal printer (AS99011), multipoint monitoring software AMOSYS2000 (up to 8 points) |
Isovelocity suction probe, purge filter, USB cable (1.8m), AC adapter, calibration certificate, traceability system diagram, manual (Japanese/paper-based), USB memory IMS software, English manual |
|
AT-R306P |
Available upon quote |
1.23Kg |
USB, Ethernet, RS485 or RS232-C (optional) /AC100~240V,DC15V2A |
50% ± 20% of the number of PSL standard particles of the corresponding particle size at the minimum measurable particle size, 100% ± 10% at 1.5 times the particle size PSL |
ISO 21501-4, JIS B-9921/1 year after purchase (2 year warranty for semiconductor laser only) |
0.3μm~10.0μm/6 channels |
Counting loss rate within 10%. 30,000,000 pieces/CF (1,060,000 pieces/m3, 1,060,000 pieces/L, 50,000 pieces/second) |
W133xD58xH177 (including exhaust port) |
2.83L (0.1CF) Automatic flow rate detection with built-in flow controller, P type automatically adjusts flow rate, tube extension within 5m (depending on conditions) |
1 count/60 minutes at minimum measurable particle size |
Operating temperature 5℃~40℃/Storage temperature 0℃~50℃, relative humidity 20%~95% (no condensation) |
500 locations, 20 characters input |
The minimum measurable particle size is fixed. Particle size can be set in 0.01um steps beyond that range. |
Display (4.3inWQVAG color touch screen), icon operation |
45,000 (Can be called at any time on the device screen even during measurement, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Built-in pump |
Count, concentration, temperature/humidity (when optional temperature/humidity sensor is installed), red screen display, beep |
Carrying case (AS99015T), temperature and humidity sensor (EE80014A), dedicated thermal printer (AS99011), multipoint monitoring software AMOSYS2000 (up to 8 points) |
Isovelocity suction probe, purge filter, USB cable (1.8m), AC adapter, calibration certificate, traceability system diagram, manual (Japanese/paper-based), USB memory IMS software, English manual |
|
AT-R506 |
Available upon quote |
1.18Kg |
USB, Ethernet, RS485 or RS232-C (optional) /AC100~240V,DC15V2A |
50% ± 20% of the number of PSL standard particles of the corresponding particle size at the minimum measurable particle size, 100% ± 10% at 1.5 times the particle size PSL |
ISO 21501-4, JIS B-9921/1 year after purchase (2 year warranty for semiconductor laser only) |
0.5μm~10.0μm/6 channels |
Counting loss rate within 10%. 30,000,000 pieces/CF (1,060,000 pieces/m3, 1,060,000 pieces/L, 50,000 pieces/second) |
W133xD58xH193 |
2.83L (0.1CF) Automatic flow rate detection with built-in flow controller, P type automatically adjusts flow rate, tube extension within 5m (depending on conditions) |
1 count/60 minutes at minimum measurable particle size |
Operating temperature 5℃~40℃/Storage temperature 0℃~50℃, relative humidity 20%~95% (no condensation) |
500 locations, 20 characters input |
The minimum measurable particle size is fixed. Particle size can be set in 0.01um steps beyond that range. |
Display (4.3inWQVAG color touch screen), icon operation |
45,000 (Can be called at any time on the device screen even during measurement, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Without pump (>38.1cmhg) |
Count, concentration, temperature/humidity (when optional temperature/humidity sensor is installed), red screen display, beep |
Carrying case (AS99015T), temperature and humidity sensor (EE80014A), dedicated thermal printer (AS99011), multipoint monitoring software AMOSYS2000 (up to 8 points) |
Isovelocity suction probe, purge filter, USB cable (1.8m), AC adapter, calibration certificate, traceability system diagram, manual (Japanese/paper-based), USB memory IMS software, English manual |
|
AT-R506P |
Available upon quote |
1.23Kg |
USB, Ethernet, RS485 or RS232-C (optional) /AC100~240V,DC15V2A |
50% ± 20% of the number of PSL standard particles of the corresponding particle size at the minimum measurable particle size, 100% ± 10% at 1.5 times the particle size PSL |
ISO 21501-4, JIS B-9921/1 year after purchase (2 year warranty for semiconductor laser only) |
0.5μm~10.0μm/6 channels |
Counting loss rate within 10%. 30,000,000 pieces/CF (1,060,000 pieces/m3, 1,060,000 pieces/L, 50,000 pieces/second) |
W133xD58xH177 (including exhaust port) |
2.83L (0.1CF) Automatic flow rate detection with built-in flow controller, P type automatically adjusts flow rate, tube extension within 5m (depending on conditions) |
1 count/60 minutes at minimum measurable particle size |
Operating temperature 5℃~40℃/Storage temperature 0℃~50℃, relative humidity 20%~95% (no condensation) |
500 locations, 20 characters input |
The minimum measurable particle size is fixed. Particle size can be set in 0.01um steps beyond that range. |
Display (4.3inWQVAG color touch screen), icon operation |
45,000 (Can be called at any time on the device screen even during measurement, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Built-in pump |
Count, concentration, temperature/humidity (when optional temperature/humidity sensor is installed), red screen display, beep |
Carrying case (AS99015T), temperature and humidity sensor (EE80014A), dedicated thermal printer (AS99011), multipoint monitoring software AMOSYS2000 (up to 8 points) |
Isovelocity suction probe, purge filter, USB cable (1.8m), AC adapter, calibration certificate, traceability system diagram, manual (Japanese/paper-based), USB memory IMS software, English manual |
Click on the part number for more information about each product