All Categories
History
Product
Air quality monitor for ultra-high concentration of fine particles AQM seriesHandling Company
Particles Plus, Inc.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply | Weight | Counting efficiency/false counting | Particle size/number of channels | Environmental sensor specifications TVOC | Environmental sensor specifications CO2 | Measurement target | Temperature and humidity | Proofreading | Maximum measurable concentration | Old model | Size | Suction flow rate (built-in pump) | Output/mode | Light source | Guarantee | Usage environment/storage environment | Location recipe | User interface | Memory | Printer | Battery | Communication | Carrying case | Alarm | Standard | Option | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5300AQM-1 |
Available upon quote |
110-240V 50/60Hz Universal Inline Power Supply |
1.2kg |
50%±20% at 0.3μmPSL, 100%±10% at 0.45μmPSL at 0.3μm・1 count/160 minutes |
0.3~10.0um/6 steps/Particle size factory setting: 0.3, 0.5, 1.0, 2.5, 5.0, 10.0um or more/Minimum measurable particle size is fixed, particle size is set in 0.01um steps within the minimum to maximum particle size range Possible |
None |
0-5,000ppm, resolution 1ppm, Accuracy±1%FS, reaction time 20 seconds |
Particles (light scattering), CO2 (NDIR), temperature and humidity |
0℃-50℃±0.5℃/RH15-90%±2% |
NIST,JQA |
70,080,000 pieces/CF, 2,500 pieces/CC, 118,000 pieces/sec at 10% simultaneous passing loss rate |
5301AQM-LF |
W133×D58xH226 |
1.2Lm, automatic flow adjustment with built-in flow controller (tube extension within 5m) |
Atmospheric pressure, temperature, humidity, CO2 concentration, TVOC concentration, particle diameter number, cumulative number/real-time meter & graph, converted number per m3/CF, mass concentration (PM/m3) converted value |
Semiconductor laser |
1 year warranty, 2 years warranty for light source, 1 year warranty for TVOC sensor and CO2 sensor (depending on usage conditions) |
Usage environment: 5-40℃/humidity 20%-95%, storage environment: 0-50℃/0-98%, non-condensing. |
500 locations (20 character index can be entered) ・150 recipes |
Display (4.3in.WQVAG color touch screen), icon touch operation |
45,000 sample records (can be recalled on screen, output to PC, readable on USB memory) |
Option, thermal printer (each value, MAX/MIN. average value, date, calibration date, ISO/FDA/GMP report) |
None |
Ethernet, USB, optional RS232/485 |
Option, AS99015T, hard plastic with accidental release prevention locking function |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) - External alarm output (factory option) |
ISO21501-4, JISB-9921 |
AQM Field Calibration Cap Kit AMOSYS-2000 Multi-point monitoring software (up to 8 Ethernet units) Replacement calibrated spare sensors (up to 3 units/factory option) |
Isokinetic suction probe, purge filter, USB memory, USB cable (1.8m), IMS monitoring/control software |
|
5300AQM-2 |
Available upon quote |
110-240V 50/60Hz Universal Inline Power Supply |
1.2kg |
50%±20% at 0.3μmPSL, 100%±10% at 0.45μmPSL at 0.3μm・1 count/160 minutes |
0.3~10.0um/6 steps/Particle size factory setting: 0.3, 0.5, 1.0, 2.5, 5.0, 10.0um or more/Minimum measurable particle size is fixed, particle size is set in 0.01um steps within the minimum to maximum particle size range Possible |
5ppb,0-50ppm/min Accuracy±1.5%,Reaction time <3 seconds |
0-5,000ppm, resolution 1ppm, Accuracy±1%FS, reaction time 20 seconds |
Particles (light scattering), CO2 (NDIR), TVOC (PID), temperature and humidity |
0℃-50℃±0.5℃/RH15-90%±2% |
NIST,JQA |
70,080,000 pieces/CF, 2,500 pieces/CC, 118,000 pieces/sec at 10% simultaneous passing loss rate |
5302AQM-LF |
W133×D58xH226 |
1.2Lm, automatic flow adjustment with built-in flow controller (tube extension within 5m) |
Atmospheric pressure, temperature, humidity, CO2 concentration, TVOC concentration, particle diameter number, cumulative number/real-time meter & graph, converted number per m3/CF, mass concentration (PM/m3) converted value |
Semiconductor laser |
1 year warranty, 2 years warranty for light source, 1 year warranty for TVOC sensor and CO2 sensor (depending on usage conditions) |
Usage environment: 5-40℃/humidity 20%-95%, storage environment: 0-50℃/0-98%, non-condensing. |
500 locations (20 character index can be entered) ・150 recipes |
Display (4.3in.WQVAG color touch screen), icon touch operation |
45,000 sample records (can be recalled on screen, output to PC, readable on USB memory) |
Option, thermal printer (each value, MAX/MIN. average value, date, calibration date, ISO/FDA/GMP report) |
None |
Ethernet, USB, optional RS232/485 |
Option, AS99015T, hard plastic with accidental release prevention locking function |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) - External alarm output (factory option) |
ISO21501-4, JISB-9921 |
AQM Field Calibration Cap Kit AMOSYS-2000 Multi-point monitoring software (up to 8 Ethernet units) Replacement calibrated spare sensors (up to 3 units/factory option) |
Isokinetic suction probe, purge filter, USB memory, USB cable (1.8m), IMS monitoring/control software |
|
7300AQM-1 |
Available upon quote |
110-240V 50/60Hz Universal Inline Power Supply |
1.8kg |
50%±20% at 0.3μmPSL, 100%±10% at 0.45μmPSL at 0.3μm・1 count/160 minutes |
0.3~10.0um/6 steps/Particle size factory setting: 0.3, 0.5, 1.0, 2.5, 5.0, 10.0um or more/Minimum measurable particle size is fixed, particle size is set in 0.01um steps within the minimum to maximum particle size range Possible |
None |
0-5,000ppm, resolution 1ppm, Accuracy±1%FS, reaction time 20 seconds |
Particles (light scattering), CO2 (NDIR), temperature and humidity |
0℃-50℃±0.5℃/RH15-90%±2% |
NIST,JQA |
70,080,000 pieces/CF, 2,500 pieces/CC, 118,000 pieces/sec at 10% simultaneous passing loss rate |
7301AQM-LF |
W133xD105xH210 |
1.2Lm, automatic flow adjustment with built-in flow controller (tube extension within 5m) |
Atmospheric pressure, temperature, humidity, CO2 concentration, TVOC concentration, particle diameter number, cumulative number/real-time meter & graph, converted number per m3/CF, mass concentration (PM/m3) converted value |
Semiconductor laser |
1 year warranty, 2 years warranty for light source, 1 year warranty for TVOC sensor and CO2 sensor (depending on usage conditions) |
Usage environment: 5-40℃/humidity 20%-95%, storage environment: 0-50℃/0-98%, non-condensing. |
500 locations (20 character index can be entered) ・150 recipes |
Display (4.3in.WQVAG color touch screen), icon touch operation |
45,000 sample records (can be recalled on screen, output to PC, readable on USB memory) |
Option, thermal printer (each value, MAX/MIN. average value, date, calibration date, ISO/FDA/GMP report) |
Lithium-ion battery 55W, 8 hours continuous, 4 hours recharging (dedicated charger) |
Ethernet, USB, optional RS232/485 |
Option, AS99015T, hard plastic with accidental release prevention locking function |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) - External alarm output (factory option) |
ISO21501-4, JISB-9921 |
AQM Field Calibration Cap Kit AMOSYS-2000 Multi-point monitoring software (up to 8 Ethernet units) Replacement calibrated spare sensors (up to 3 units/factory option) |
Isokinetic suction probe, purge filter, USB memory, USB cable (1.8m), IMS monitoring/control software |
|
7300AQM-2 |
Available upon quote |
110-240V 50/60Hz Universal Inline Power Supply |
1.8kg |
50%±20% at 0.3μmPSL, 100%±10% at 0.45μmPSL at 0.3μm・1 count/160 minutes |
0.3~10.0um/6 steps/Particle size factory setting: 0.3, 0.5, 1.0, 2.5, 5.0, 10.0um or more/Minimum measurable particle size is fixed, particle size is set in 0.01um steps within the minimum to maximum particle size range Possible |
5ppb,0-50ppm/min Accuracy±1.5%,Reaction time <3 seconds |
0-5,000ppm, resolution 1ppm, Accuracy±1%FS, reaction time 20 seconds |
Particles (light scattering), CO2 (NDIR), TVOC (PID), temperature and humidity |
0℃-50℃±0.5℃/RH15-90%±2% |
NIST,JQA |
70,080,000 pieces/CF, 2,500 pieces/CC, 118,000 pieces/sec at 10% simultaneous passing loss rate |
7302AQM-LF |
W133xD105xH210 |
1.2Lm, automatic flow adjustment with built-in flow controller (tube extension within 5m) |
Atmospheric pressure, temperature, humidity, CO2 concentration, TVOC concentration, particle diameter number, cumulative number/real-time meter & graph, converted number per m3/CF, mass concentration (PM/m3) converted value |
Semiconductor laser |
1 year warranty, 2 years warranty for light source, 1 year warranty for TVOC sensor and CO2 sensor (depending on usage conditions) |
Usage environment: 5-40℃/humidity 20%-95%, storage environment: 0-50℃/0-98%, non-condensing. |
500 locations (20 character index can be entered) ・150 recipes |
Display (4.3in.WQVAG color touch screen), icon touch operation |
45,000 sample records (can be recalled on screen, output to PC, readable on USB memory) |
Option, thermal printer (each value, MAX/MIN. average value, date, calibration date, ISO/FDA/GMP report) |
Lithium-ion battery 55W, 8 hours continuous, 4 hours recharging (dedicated charger) |
Ethernet, USB, optional RS232/485 |
Option, AS99015T, hard plastic with accidental release prevention locking function |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) - External alarm output (factory option) |
ISO21501-4, JISB-9921 |
AQM Field Calibration Cap Kit AMOSYS-2000 Multi-point monitoring software (up to 8 Ethernet units) Replacement calibrated spare sensors (up to 3 units/factory option) |
Isokinetic suction probe, purge filter, USB memory, USB cable (1.8m), IMS monitoring/control software |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.