All Categories
History
Product
Remote particle counter Model remote 5301/5301P/7301Handling Company
Particles Plus, Inc.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply | Weight | Counting efficiency/false counting | Standards/Warranty | Measuring range | Temperature and humidity sensor | Maximum measurable concentration | Size | Multipoint monitoring software (optional) | Suction flow rate (per minute) | Particle size setting at time of shipment (0.3μm type) | Light source | Storage environment | Usage environment | Location/recipe settings | User selectable settings | User interface | Mode | Memory/Login interval | Pump (vacuum source) | Printer (optional) | Factory options | Communication | Carrying case (optional) | Alarm | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5301 |
Available upon quote |
110-240VAC 50/60Hz universal in-lime power surply Built-in backup battery only |
1.18kg |
50%±20% at 0.3μmPSL, 100%±10% at 0.45μmPSL at 0.3μm・1 count/60 minutes |
ISO21501-4, JIS B 9921・1 year, however, light source is 2 years |
0.3μm~10.0μm or more |
Options Model EE80014A (0-60℃±0.5℃, 15-90%±2%) |
30,000,000 pieces/CF (1,060,000 pieces/L, 50,000 pieces/second) Within 10% simultaneous passage counting loss. |
W133xD58xH193 |
Up to 8 points via AMOSYS2000 Ethernet |
0.1CFM (approximately 2.83LM), automatic flow rate detection with built-in flow controller, P is automatic flow rate adjustment, tube extension within 5m (under atmospheric pressure) |
0.3, 0.5, 1.0, 2.5, 5.0, 10.0μm |
Semiconductor laser |
0℃-50℃ (No condensation) |
5℃-40℃/relative humidity 20%-95% (non-condensing) |
500 locations (20 character index can be entered) ・150 recipes |
The minimum measurable particle size is fixed, and the particle size can be set in 0.01μm steps within the minimum to maximum measurable particle size range (calibration is only for particle size at the time of shipment) |
Display (4.3in.WQVAG color touch screen) Icon touch operation |
Manual, automatic, particle diameter value (difference)/total value, mass concentration conversion, real-time meter, battery sleep mode (7301, 7501 only) |
45,000 data (can be called up on screen, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Without pump (>38.1cmHg) |
Separately sold dedicated thermal printer Model AS99011 |
Alarm external output, open collector |
USB, Ethernet, Modbus RS485, RS232C (optional) |
Sold separately Model AS99015T Made of hard plastic |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) |
Isovelocity suction probe, purge filter, USB cable (1.8m), lithium ion battery, AC adapter (15V2A-100~240VAC) Inspection report, calibration certificate, manual |
|
5501 |
Available upon quote |
110-240VAC 50/60Hz universal in-lime power surply Built-in backup battery only |
1.18kg |
50%±20% at 0.3μmPSL, 100%±10% at 0.45μmPSL at 0.3μm・1 count/60 minutes |
ISO21501-4, JIS B 9921・1 year, however, light source is 2 years |
0.5μm~10.0μm or more |
Options Model EE80014A (0-60℃±0.5℃, 15-90%±2%) |
30,000,000 pieces/CF (1,060,000 pieces/L, 50,000 pieces/second) Within 10% simultaneous passage counting loss. |
W133xD58xH193 |
Up to 8 points via AMOSYS2000 Ethernet |
0.1CFM (approximately 2.83LM), automatic flow rate detection with built-in flow controller, P is automatic flow rate adjustment, tube extension within 5m (under atmospheric pressure) |
0.3, 0.5, 1.0, 2.5, 5.0, 10.0μm |
Semiconductor laser |
0℃-50℃ (No condensation) |
5℃-40℃/relative humidity 20%-95% (non-condensing) |
500 locations (20 character index can be entered) ・150 recipes |
The minimum measurable particle size is fixed, and the particle size can be set in 0.01μm steps within the minimum to maximum measurable particle size range (calibration is only for particle size at the time of shipment) |
Display (4.3in.WQVAG color touch screen) Icon touch operation |
Manual, automatic, particle diameter value (difference)/total value, mass concentration conversion, real-time meter, battery sleep mode (7301, 7501 only) |
45,000 data (can be called up on screen, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Without pump (>38.1cmHg) |
Separately sold dedicated thermal printer Model AS99012 |
Alarm external output, open collector |
USB, Ethernet, Modbus RS485, RS232C (optional) |
Sold separately Model AS99015T Made of hard plastic |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) |
Isovelocity suction probe, purge filter, USB cable (1.8m), lithium ion battery, AC adapter (15V2A-100~240VAC) Inspection report, calibration certificate, manual |
|
5301P |
Available upon quote |
110-240VAC 50/60Hz universal in-lime power surply Built-in backup battery only |
1.23kg |
50%±20% at 0.3μmPSL, 100%±10% at 0.45μmPSL at 0.3μm・1 count/60 minutes |
ISO21501-4, JIS B 9921・1 year, however, light source is 2 years |
0.3μm~10.0μm or more |
Options Model EE80014A (0-60℃±0.5℃, 15-90%±2%) |
30,000,000 pieces/CF (1,060,000 pieces/L, 50,000 pieces/second) Within 10% simultaneous passage counting loss. |
W133×D58×H177 |
Up to 8 points via AMOSYS2000 Ethernet |
0.1CFM (approximately 2.83LM), automatic flow rate detection with built-in flow controller, P is automatic flow rate adjustment, tube extension within 5m (under atmospheric pressure) |
0.3, 0.5, 1.0, 2.5, 5.0, 10.0μm |
Semiconductor laser |
0℃-50℃ (No condensation) |
5℃-40℃/relative humidity 20%-95% (non-condensing) |
500 locations (20 character index can be entered) ・150 recipes |
The minimum measurable particle size is fixed, and the particle size can be set in 0.01μm steps within the minimum to maximum measurable particle size range (calibration is only for particle size at the time of shipment) |
Display (4.3in.WQVAG color touch screen) Icon touch operation |
Manual, automatic, particle diameter value (difference)/total value, mass concentration conversion, real-time meter, battery sleep mode (7301, 7501 only) |
45,000 data (can be called up on screen, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Built-in pump |
Separately sold dedicated thermal printer Model AS99013 |
Alarm external output, open collector |
USB, Ethernet, Modbus RS485, RS232C (optional) |
Sold separately Model AS99015T Made of hard plastic |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) |
Isovelocity suction probe, purge filter, USB cable (1.8m), lithium ion battery, AC adapter (15V2A-100~240VAC) Inspection report, calibration certificate, manual |
|
5501P |
Available upon quote |
110-240VAC 50/60Hz universal in-lime power surply Built-in backup battery only |
1.23kg |
50%±20% at 0.3μmPSL, 100%±10% at 0.45μmPSL at 0.3μm・1 count/60 minutes |
ISO21501-4, JIS B 9921・1 year, however, light source is 2 years |
0.5μm~10.0μm or more |
Options Model EE80014A (0-60℃±0.5℃, 15-90%±2%) |
30,000,000 pieces/CF (1,060,000 pieces/L, 50,000 pieces/second) Within 10% simultaneous passage counting loss. |
W133×D58×H177 |
Up to 8 points via AMOSYS2000 Ethernet |
0.1CFM (approximately 2.83LM), automatic flow rate detection with built-in flow controller, P is automatic flow rate adjustment, tube extension within 5m (under atmospheric pressure) |
0.3, 0.5, 1.0, 2.5, 5.0, 10.0μm |
Semiconductor laser |
0℃-50℃ (No condensation) |
5℃-40℃/relative humidity 20%-95% (non-condensing) |
500 locations (20 character index can be entered) ・150 recipes |
The minimum measurable particle size is fixed, and the particle size can be set in 0.01μm steps within the minimum to maximum measurable particle size range (calibration is only for particle size at the time of shipment) |
Display (4.3in.WQVAG color touch screen) Icon touch operation |
Manual, automatic, particle diameter value (difference)/total value, mass concentration conversion, real-time meter, battery sleep mode (7301, 7501 only) |
45,000 data (can be called up on screen, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Built-in pump |
Separately sold dedicated thermal printer Model AS99014 |
Alarm external output, open collector |
USB, Ethernet, Modbus RS485, RS232C (optional) |
Sold separately Model AS99015T Made of hard plastic |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) |
Isovelocity suction probe, purge filter, USB cable (1.8m), lithium ion battery, AC adapter (15V2A-100~240VAC) Inspection report, calibration certificate, manual |
|
7301 |
Available upon quote |
Lithium ion battery 55Wh 8 hours continuous |
1.8kg |
50%±20% at 0.3μmPSL, 100%±10% at 0.45μmPSL at 0.3μm・1 count/60 minutes |
ISO21501-4, JIS B 9921・1 year, however, light source is 2 years |
0.3μm~10.0μm or more |
Attached EE80022A |
30,000,000 pieces/CF (1,060,000 pieces/L, 50,000 pieces/second) Within 10% simultaneous passage counting loss. |
W133×D105×H210 |
Up to 8 points via AMOSYS2000 Ethernet |
0.1CFM (approximately 2.83LM), automatic flow rate detection with built-in flow controller, P is automatic flow rate adjustment, tube extension within 5m (under atmospheric pressure) |
0.3, 0.5, 1.0, 2.5, 5.0, 10.0μm |
Semiconductor laser |
0℃-50℃ (No condensation) |
5℃-40℃/relative humidity 20%-95% (non-condensing) |
500 locations (20 character index can be entered) ・150 recipes |
The minimum measurable particle size is fixed, and the particle size can be set in 0.01μm steps within the minimum to maximum measurable particle size range (calibration is only for particle size at the time of shipment) |
Display (4.3in.WQVAG color touch screen) Icon touch operation |
Manual, automatic, particle diameter value (difference)/total value, mass concentration conversion, real-time meter, battery sleep mode (7301, 7501 only) |
45,000 data (can be called up on screen, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Built-in long-life pump |
Separately sold dedicated thermal printer Model AS99015 |
Alarm external output, open collector |
USB, Ethernet, Modbus RS485, RS232C (optional) |
Sold separately Model AS99015T Made of hard plastic |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) |
Isovelocity suction probe, purge filter, USB cable (1.8m), lithium ion battery, AC adapter (15V2A-100~240VAC) Inspection report, calibration certificate, manual |
|
7501 |
Available upon quote |
Lithium ion battery 55Wh 8 hours continuous |
1.8kg |
50%±20% at 0.3μmPSL, 100%±10% at 0.45μmPSL at 0.3μm・1 count/60 minutes |
ISO21501-4, JIS B 9921・1 year, however, light source is 2 years |
0.5μm~10.0μm or more |
Attached EE80022A |
30,000,000 pieces/CF (1,060,000 pieces/L, 50,000 pieces/second) Within 10% simultaneous passage counting loss. |
W133×D105×H210 |
Up to 8 points via AMOSYS2000 Ethernet |
0.1CFM (approximately 2.83LM), automatic flow rate detection with built-in flow controller, P is automatic flow rate adjustment, tube extension within 5m (under atmospheric pressure) |
0.3, 0.5, 1.0, 2.5, 5.0, 10.0μm |
Semiconductor laser |
0℃-50℃ (No condensation) |
5℃-40℃/relative humidity 20%-95% (non-condensing) |
500 locations (20 character index can be entered) ・150 recipes |
The minimum measurable particle size is fixed, and the particle size can be set in 0.01μm steps within the minimum to maximum measurable particle size range (calibration is only for particle size at the time of shipment) |
Display (4.3in.WQVAG color touch screen) Icon touch operation |
Manual, automatic, particle diameter value (difference)/total value, mass concentration conversion, real-time meter, battery sleep mode (7301, 7501 only) |
45,000 data (can be called up on screen, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Built-in long-life pump |
Separately sold dedicated thermal printer Model AS99016 |
Alarm external output, open collector |
USB, Ethernet, Modbus RS485, RS232C (optional) |
Sold separately Model AS99015T Made of hard plastic |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) |
Isovelocity suction probe, purge filter, USB cable (1.8m), lithium ion battery, AC adapter (15V2A-100~240VAC) Inspection report, calibration certificate, manual |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.