Image | Part Number | Price (excluding tax) | Weight | Counting efficiency | Standards/Warranty | Particle size channel number | Measuring range | Size | Suction flow rate | Particle size at shipping | Light source | Storage environment | Usage environment | Number of locations/recipes | User selectable settings | Mode | Memory/log interval | Battery Lithium-ion battery (removable) | Battery full recharge time | Communication | Optional temperature/humidity sensor | Optional multi-point monitoring software | Optional printer | Optional carrying case | Alarm | Maximum measurable concentration | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8300 |
Available upon quote |
1Kg (with battery installed) |
At 0.3μmPSL 50%±20% at 0.3μm, at 0.45μmPSL 100% ±10% at 0.3μm・<1 count/60 minutes |
ISO 21504-4, JIS B-9921/1 year (2 years for light source laser only) |
6 |
0.3μm~10.0μm or more |
W129×D114×H254 (Including handle, not including constant velocity suction probe) |
1.21/min |
0.3, 0.5, 1.0, 2.5, 5.0, 10.0μm |
Long life semiconductor laser Long life (guaranteed 2 years after shipment) |
0℃-50℃ (No condensation) |
5℃-40℃/relative humidity 20%-95% (non-condensing) |
1,000 locations (20 character index can be entered) ・50 recipes |
The minimum measurable particle size is fixed, and the particle size can be set in 0.01μm steps within the minimum to maximum measurable particle size range (calibration is only for particle size at the time of shipment) |
Manual, automatic, particle diameter value (⊿) / total value (Σ) mass concentration conversion, real-time meter, battery sleep mode |
45,000 data (can be called up on screen, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Model EE80003A (55Wh, 10 hours continuous) *One unit can be hand-carried on an aircraft with the battery installed. |
4 hours when attached to the main unit, 2 hours using an external charger (sold separately) *One unit can be transported by air with the battery attached (UPS) / Two or more units can be packed with the battery removed. |
USB, Ethernet (standard), Modbus RS486 or 232C (optional) |
Model EE80014A (0-60℃±0.5℃, 0-100%±2% (8303 and 8503 are optional) |
AMOSYS2000 Ethernet up to 8 points |
Model PS99011 Thermal printer paper width 50mm with 2 rolls of plain paper |
Sold separately/Model AS99015T hard plastic, with accidental release prevention mechanism |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) |
2,500 pieces/CC, 78,000,000 pieces/CF |
Isovelocity suction probe, purge filter, USB cable (1.8m), lithium ion battery AC adapter (15V2A-100~240VAC) Inspection report, calibration certificate, manual, IMS software |
|
8303 |
Available upon quote |
1Kg (with battery installed) |
At 0.3μmPSL 50%±20% at 0.3μm, at 0.45μmPSL 100% ±10% at 0.3μm・<1 count/60 minutes |
ISO 21504-4, JIS B-9921/1 year (2 years for light source laser only) |
3 |
0.3μm~10.0μm or more |
W129×D114×H254 (Including handle, not including constant velocity suction probe) |
2.83L/min |
0.3, 0.5, 10.0μm |
Long life semiconductor laser Long life (guaranteed 2 years after shipment) |
0℃-50℃ (No condensation) |
5℃-40℃/relative humidity 20%-95% (non-condensing) |
1,000 locations (20 character index can be entered) ・50 recipes |
The minimum measurable particle size is fixed, and the particle size can be set in 0.01μm steps within the minimum to maximum measurable particle size range (calibration is only for particle size at the time of shipment) |
Manual, automatic, particle diameter value (⊿) / total value (Σ) mass concentration conversion, real-time meter, battery sleep mode |
45,000 data (can be called up on screen, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Model EE80003A (55Wh, 10 hours continuous) *One unit can be hand-carried on an aircraft with the battery installed. |
4 hours when attached to the main unit, 2 hours using an external charger (sold separately) *One unit can be transported by air with the battery attached (UPS) / Two or more units can be packed with the battery removed. |
USB, Ethernet (standard), Modbus RS486 or 232C (optional) |
Model EE80014A (0-60℃±0.5℃, 0-100%±2% (8303 and 8503 are optional) |
AMOSYS2000 Ethernet up to 8 points |
Model PS99011 Thermal printer paper width 50mm with 2 rolls of plain paper |
Sold separately/Model AS99015T hard plastic, with accidental release prevention mechanism |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) |
- |
Isovelocity suction probe, purge filter, USB cable (1.8m), lithium ion battery AC adapter (15V2A-100~240VAC) Inspection report, calibration certificate, manual, IMS software |
|
8503 |
Available upon quote |
1Kg (with battery installed) |
At 0.3μmPSL 50%±20% at 0.3μm, at 0.45μmPSL 100% ±10% at 0.3μm・<1 count/60 minutes |
ISO 21504-4, JIS B-9921/1 year (2 years for light source laser only) |
3 |
0.5μm~10.0μm or more |
W129×D114×H254 (Including handle, not including constant velocity suction probe) |
2.83L/min |
0.5, 1.0, 10.0μm |
Long life semiconductor laser Long life (guaranteed 2 years after shipment) |
0℃-50℃ (No condensation) |
5℃-40℃/relative humidity 20%-95% (non-condensing) |
1,000 locations (20 character index can be entered) ・50 recipes |
The minimum measurable particle size is fixed, and the particle size can be set in 0.01μm steps within the minimum to maximum measurable particle size range (calibration is only for particle size at the time of shipment) |
Manual, automatic, particle diameter value (⊿) / total value (Σ) mass concentration conversion, real-time meter, battery sleep mode |
45,000 data (can be called up on screen, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Model EE80003A (55Wh, 10 hours continuous) *One unit can be hand-carried on an aircraft with the battery installed. |
4 hours when attached to the main unit, 2 hours using an external charger (sold separately) *One unit can be transported by air with the battery attached (UPS) / Two or more units can be packed with the battery removed. |
USB, Ethernet (standard), Modbus RS486 or 232C (optional) |
Model EE80014A (0-60℃±0.5℃, 0-100%±2% (8303 and 8503 are optional) |
AMOSYS2000 Ethernet up to 8 points |
Model PS99011 Thermal printer paper width 50mm with 2 rolls of plain paper |
Sold separately/Model AS99015T hard plastic, with accidental release prevention mechanism |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) |
- |
Isovelocity suction probe, purge filter, USB cable (1.8m), lithium ion battery AC adapter (15V2A-100~240VAC) Inspection report, calibration certificate, manual, IMS software |
|
8306 |
Available upon quote |
1Kg (with battery installed) |
At 0.3μmPSL 50%±20% at 0.3μm, at 0.45μmPSL 100% ±10% at 0.3μm・<1 count/60 minutes |
ISO 21504-4, JIS B-9921/1 year (2 years for light source laser only) |
6 |
0.3μm~10.0μm or more |
W129×D114×H254 (Including handle, not including constant velocity suction probe) |
2.83L/min |
0.3, 0.5, 1.0, 2.5, 5.0, 10.0μm |
Long life semiconductor laser Long life (guaranteed 2 years after shipment) |
0℃-50℃ (No condensation) |
5℃-40℃/relative humidity 20%-95% (non-condensing) |
1,000 locations (20 character index can be entered) ・50 recipes |
The minimum measurable particle size is fixed, and the particle size can be set in 0.01μm steps within the minimum to maximum measurable particle size range (calibration is only for particle size at the time of shipment) |
Manual, automatic, particle diameter value (⊿) / total value (Σ) mass concentration conversion, real-time meter, battery sleep mode |
45,000 data (can be called up on screen, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Model EE80003A (55Wh, 10 hours continuous) *One unit can be hand-carried on an aircraft with the battery installed. |
4 hours when attached to the main unit, 2 hours using an external charger (sold separately) *One unit can be transported by air with the battery attached (UPS) / Two or more units can be packed with the battery removed. |
USB, Ethernet (standard), Modbus RS486 or 232C (optional) |
Model EE80014A (0-60℃±0.5℃, 0-100%±2% (8303 and 8503 are optional) |
AMOSYS2000 Ethernet up to 8 points |
Model PS99011 Thermal printer paper width 50mm with 2 rolls of plain paper |
Sold separately/Model AS99015T hard plastic, with accidental release prevention mechanism |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) |
1,060 pieces/CC, 30,000,000 pieces/CF |
Isovelocity suction probe, purge filter, USB cable (1.8m), lithium ion battery AC adapter (15V2A-100~240VAC) Inspection report, calibration certificate, manual, IMS software |
|
8506 |
Available upon quote |
1Kg (with battery installed) |
At 0.3μmPSL 50%±20% at 0.3μm, at 0.45μmPSL 100% ±10% at 0.3μm・<1 count/60 minutes |
ISO 21504-4, JIS B-9921/1 year (2 years for light source laser only) |
6 |
0.5μm~10.0μm or more |
W129×D114×H254 (Including handle, not including constant velocity suction probe) |
2.83L/min |
0.5, 0.7, 1.0, 2.5, 5.0, 10.0μm |
Long life semiconductor laser Long life (guaranteed 2 years after shipment) |
0℃-50℃ (No condensation) |
5℃-40℃/relative humidity 20%-95% (non-condensing) |
1,000 locations (20 character index can be entered) ・50 recipes |
The minimum measurable particle size is fixed, and the particle size can be set in 0.01μm steps within the minimum to maximum measurable particle size range (calibration is only for particle size at the time of shipment) |
Manual, automatic, particle diameter value (⊿) / total value (Σ) mass concentration conversion, real-time meter, battery sleep mode |
45,000 data (can be called up on screen, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Model EE80003A (55Wh, 10 hours continuous) *One unit can be hand-carried on an aircraft with the battery installed. |
4 hours when attached to the main unit, 2 hours using an external charger (sold separately) *One unit can be transported by air with the battery attached (UPS) / Two or more units can be packed with the battery removed. |
USB, Ethernet (standard), Modbus RS486 or 232C (optional) |
Model EE80014A (0-60℃±0.5℃, 0-100%±2% (8303 and 8503 are optional) |
AMOSYS2000 Ethernet up to 8 points |
Model PS99011 Thermal printer paper width 50mm with 2 rolls of plain paper |
Sold separately/Model AS99015T hard plastic, with accidental release prevention mechanism |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) |
1,060 pieces/CC, 30,000,000 pieces/CF |
Isovelocity suction probe, purge filter, USB cable (1.8m), lithium ion battery AC adapter (15V2A-100~240VAC) Inspection report, calibration certificate, manual, IMS software |
|
8506-30 |
Available upon quote |
1Kg (with battery installed) |
At 0.3μmPSL 50%±20% at 0.3μm, at 0.45μmPSL 100% ±10% at 0.3μm・<1 count/60 minutes |
ISO 21504-4, JIS B-9921/1 year (2 years for light source laser only) |
6 |
0.5μm~30.0μm or more |
W129×D114×H254 (Including handle, not including constant velocity suction probe) |
2.83L/min |
0.5, 1.0, 5.0, 10.0, 20.0, 30.0μm |
Long life semiconductor laser Long life (guaranteed 2 years after shipment) |
0℃-50℃ (No condensation) |
5℃-40℃/relative humidity 20%-95% (non-condensing) |
1,000 locations (20 character index can be entered) ・50 recipes |
The minimum measurable particle size is fixed, and the particle size can be set in 0.01μm steps within the minimum to maximum measurable particle size range (calibration is only for particle size at the time of shipment) |
Manual, automatic, particle diameter value (⊿) / total value (Σ) mass concentration conversion, real-time meter, battery sleep mode |
45,000 data (can be called up on screen, output to PC, read out on USB memory) / 1 second to 99 hours without hold time |
Model EE80003A (55Wh, 10 hours continuous) *One unit can be hand-carried on an aircraft with the battery installed. |
4 hours when attached to the main unit, 2 hours using an external charger (sold separately) *One unit can be transported by air with the battery attached (UPS) / Two or more units can be packed with the battery removed. |
USB, Ethernet (standard), Modbus RS486 or 232C (optional) |
Model EE80014A (0-60℃±0.5℃, 0-100%±2% (8303 and 8503 are optional) |
AMOSYS2000 Ethernet up to 8 points |
Model PS99011 Thermal printer paper width 50mm with 2 rolls of plain paper |
Sold separately/Model AS99015T hard plastic, with accidental release prevention mechanism |
Set by count, concentration, μg, temperature/humidity (beep sound, red display on screen) |
- |
Isovelocity suction probe, purge filter, USB cable (1.8m), lithium ion battery AC adapter (15V2A-100~240VAC) Inspection report, calibration certificate, manual, IMS software |
Click on the part number for more information about each product