Intelligent control output distributor IOPDHandling Company
RKC INSTRUMENTCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply voltage | Current detector input (CT) | Communication speed | Communication function | Communication method | Load power supply voltage measurement input Allowable frequency fluctuation | Load power supply voltage measurement input sampling period | Load power supply voltage measurement input input range | Load power supply voltage measurement input Number of input points | Load power supply voltage measurement input (PT input) | Alarm function | Minimum ON time | Maximum number of connected devices | Synchronization method | Control output | Control method | Control input accuracy | Control input resolution | Control input | Factory initial settings | Output load voltage | Output Allowable load current | Voltage drop when output is ON | Leakage current when output is OFF | Additional functions | Sampling period | Input type | Input impedance | CT input type | Number of channels |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
IOPD16-L-C*C6N |
Available upon quote |
DC20.4~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Accuracy: ±2% OF READING or ±1.0A, whichever is greater *CT accuracy not included |
9,600bps, 19,200bps, 38,400bps, 57,600bps |
RS-485 [2-wire] MODBUS protocol |
RS-485 2-wire half-duplex multidrop connection |
50Hz±2Hz or 60Hz±2Hz |
1/2 cycle of load power supply cycle |
85V~242V AC |
1 point |
Accuracy: ±4% OF READING |
Heater burnout alarm (HBA) / Output current upper limit alarm / SSR short circuit abnormality alarm / Output shortage alarm / Load power supply voltage abnormality alarm / Load power supply frequency abnormality alarm |
1 cycle of load power supply cycle |
31 units |
Half-duplex step synchronization type |
Transistor output (source method) |
Zero cross control (continuous proportion) |
±1% OF SPAN (accuracy of captured manipulated variable) |
Time proportional cycle setting 0.1~10.0 seconds: approx. 1/100~1/10,000 |
Upper controller transistor (open collector) output (sink method) Input pulse L active |
None (no initial setting specified) |
DC8~30V |
100mA |
0.5V or less (at allowable load current) |
100μA or less |
Peak power suppression function, slope setting function, output monitor function |
0.1~10.0 seconds or 1~100 seconds (when the control method is continuous proportional method) |
Voltage pulse input DC0/12V or DC0/24V (common to all CHs) |
13kΩ or more |
16 points CTL-10-CLS (clamp type) [Current transformation ratio 3,000:1] |
16 points |
![]() |
IOPD16-L-C*C7N |
Available upon quote |
DC20.4~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Accuracy: ±2% OF READING or ±1.0A, whichever is greater *CT accuracy not included |
9,600bps, 19,200bps, 38,400bps, 57,600bps |
RS-422A [4-wire] MODBUS protocol |
RS-422A 4-wire half-duplex multidrop connection |
50Hz±2Hz or 60Hz±2Hz |
1/2 cycle of load power supply cycle |
85V~242V AC |
1 point |
Accuracy: ±4% OF READING |
Heater burnout alarm (HBA) / Output current upper limit alarm / SSR short circuit abnormality alarm / Output shortage alarm / Load power supply voltage abnormality alarm / Load power supply frequency abnormality alarm |
1 cycle of load power supply cycle |
31 units |
Half-duplex step synchronization type |
Transistor output (source method) |
Zero cross control (continuous proportion) |
±1% OF SPAN (accuracy of captured manipulated variable) |
Time proportional cycle setting 0.1~10.0 seconds: approx. 1/100~1/10,000 |
Upper controller transistor (open collector) output (sink method) Input pulse L active |
None (no initial setting specified) |
DC8~30V |
100mA |
0.5V or less (at allowable load current) |
100μA or less |
Peak power suppression function, slope setting function, output monitor function |
0.1~10.0 seconds or 1~100 seconds (when the control method is continuous proportional method) |
Voltage pulse input DC0/12V or DC0/24V (common to all CHs) |
13kΩ or more |
16 points CTL-10-CLS (clamp type) [Current transformation ratio 3,000:1] |
16 points |
![]() |
IOPD16-L-C*P6N |
Available upon quote |
DC20.4~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Accuracy: ±2% OF READING or ±1.0A, whichever is greater *CT accuracy not included |
9,600bps, 19,200bps, 38,400bps, 57,600bps |
RS-485 [2-wire] MODBUS protocol |
RS-485 2-wire half-duplex multidrop connection |
50Hz±2Hz or 60Hz±2Hz |
1/2 cycle of load power supply cycle |
85V~242V AC |
1 point |
Accuracy: ±4% OF READING |
Heater burnout alarm (HBA) / Output current upper limit alarm / SSR short circuit abnormality alarm / Output shortage alarm / Load power supply voltage abnormality alarm / Load power supply frequency abnormality alarm |
1 cycle of load power supply cycle |
31 units |
Half-duplex step synchronization type |
Transistor output (source method) |
Zero cross control (continuous proportion) |
±1% OF SPAN (accuracy of captured manipulated variable) |
Time proportional cycle setting 0.1~10.0 seconds: approx. 1/100~1/10,000 |
Upper controller transistor (open collector) output (sink method) Input pulse L active |
None (no initial setting specified) |
DC8~30V |
100mA |
0.5V or less (at allowable load current) |
100μA or less |
Peak power suppression function, slope setting function, output monitor function |
0.1~10.0 seconds or 1~100 seconds (when the control method is continuous proportional method) |
Voltage pulse input DC0/12V or DC0/24V (common to all CHs) |
13kΩ or more |
16 points CTL-6-P-N (through type) [current transformation ratio 800:1] |
16 points |
![]() |
IOPD16-L-C*P7N |
Available upon quote |
DC20.4~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Accuracy: ±2% OF READING or ±1.0A, whichever is greater *CT accuracy not included |
9,600bps, 19,200bps, 38,400bps, 57,600bps |
RS-422A [4-wire] MODBUS protocol |
RS-422A 4-wire half-duplex multidrop connection |
50Hz±2Hz or 60Hz±2Hz |
1/2 cycle of load power supply cycle |
85V~242V AC |
1 point |
Accuracy: ±4% OF READING |
Heater burnout alarm (HBA) / Output current upper limit alarm / SSR short circuit abnormality alarm / Output shortage alarm / Load power supply voltage abnormality alarm / Load power supply frequency abnormality alarm |
1 cycle of load power supply cycle |
31 units |
Half-duplex step synchronization type |
Transistor output (source method) |
Zero cross control (continuous proportion) |
±1% OF SPAN (accuracy of captured manipulated variable) |
Time proportional cycle setting 0.1~10.0 seconds: approx. 1/100~1/10,000 |
Upper controller transistor (open collector) output (sink method) Input pulse L active |
None (no initial setting specified) |
DC8~30V |
100mA |
0.5V or less (at allowable load current) |
100μA or less |
Peak power suppression function, slope setting function, output monitor function |
0.1~10.0 seconds or 1~100 seconds (when the control method is continuous proportional method) |
Voltage pulse input DC0/12V or DC0/24V (common to all CHs) |
13kΩ or more |
16 points CTL-6-P-N (through type) [current transformation ratio 800:1] |
16 points |
![]() |
IOPD16-L-C*S6N |
Available upon quote |
DC20.4~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Accuracy: ±2% OF READING or ±1.0A, whichever is greater *CT accuracy not included |
9,600bps, 19,200bps, 38,400bps, 57,600bps |
RS-485 [2-wire] MODBUS protocol |
RS-485 2-wire half-duplex multidrop connection |
50Hz±2Hz or 60Hz±2Hz |
1/2 cycle of load power supply cycle |
85V~242V AC |
1 point |
Accuracy: ±4% OF READING |
Heater burnout alarm (HBA) / Output current upper limit alarm / SSR short circuit abnormality alarm / Output shortage alarm / Load power supply voltage abnormality alarm / Load power supply frequency abnormality alarm |
1 cycle of load power supply cycle |
31 units |
Half-duplex step synchronization type |
Transistor output (source method) |
Zero cross control (continuous proportion) |
±1% OF SPAN (accuracy of captured manipulated variable) |
Time proportional cycle setting 0.1~10.0 seconds: approx. 1/100~1/10,000 |
Upper controller transistor (open collector) output (sink method) Input pulse L active |
None (no initial setting specified) |
DC8~30V |
100mA |
0.5V or less (at allowable load current) |
100μA or less |
Peak power suppression function, slope setting function, output monitor function |
0.1~10.0 seconds or 1~100 seconds (when the control method is continuous proportional method) |
Voltage pulse input DC0/12V or DC0/24V (common to all CHs) |
13kΩ or more |
16 points CTL-12-S56-10L-N (through type) [Current transformation ratio 1,000:1] |
16 points |
![]() |
IOPD16-L-C*S7N |
Available upon quote |
DC20.4~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Accuracy: ±2% OF READING or ±1.0A, whichever is greater *CT accuracy not included |
9,600bps, 19,200bps, 38,400bps, 57,600bps |
RS-422A [4-wire] MODBUS protocol |
RS-422A 4-wire half-duplex multidrop connection |
50Hz±2Hz or 60Hz±2Hz |
1/2 cycle of load power supply cycle |
85V~242V AC |
1 point |
Accuracy: ±4% OF READING |
Heater burnout alarm (HBA) / Output current upper limit alarm / SSR short circuit abnormality alarm / Output shortage alarm / Load power supply voltage abnormality alarm / Load power supply frequency abnormality alarm |
1 cycle of load power supply cycle |
31 units |
Half-duplex step synchronization type |
Transistor output (source method) |
Zero cross control (continuous proportion) |
±1% OF SPAN (accuracy of captured manipulated variable) |
Time proportional cycle setting 0.1~10.0 seconds: approx. 1/100~1/10,000 |
Upper controller transistor (open collector) output (sink method) Input pulse L active |
None (no initial setting specified) |
DC8~30V |
100mA |
0.5V or less (at allowable load current) |
100μA or less |
Peak power suppression function, slope setting function, output monitor function |
0.1~10.0 seconds or 1~100 seconds (when the control method is continuous proportional method) |
Voltage pulse input DC0/12V or DC0/24V (common to all CHs) |
13kΩ or more |
16 points CTL-12-S56-10L-N (through type) [Current transformation ratio 1,000:1] |
16 points |
![]() |
IOPD16-L-C*L6N |
Available upon quote |
DC20.4~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Accuracy: ±2% OF READING or ±1.0A, whichever is greater *CT accuracy not included |
9,600bps, 19,200bps, 38,400bps, 57,600bps |
RS-485 [2-wire] MODBUS protocol |
RS-485 2-wire half-duplex multidrop connection |
50Hz±2Hz or 60Hz±2Hz |
1/2 cycle of load power supply cycle |
85V~242V AC |
1 point |
Accuracy: ±4% OF READING |
Heater burnout alarm (HBA) / Output current upper limit alarm / SSR short circuit abnormality alarm / Output shortage alarm / Load power supply voltage abnormality alarm / Load power supply frequency abnormality alarm |
1 cycle of load power supply cycle |
31 units |
Half-duplex step synchronization type |
Transistor output (source method) |
Zero cross control (continuous proportion) |
±1% OF SPAN (accuracy of captured manipulated variable) |
Time proportional cycle setting 0.1~10.0 seconds: approx. 1/100~1/10,000 |
Upper controller transistor (open collector) output (sink method) Input pulse L active |
None (no initial setting specified) |
DC8~30V |
100mA |
0.5V or less (at allowable load current) |
100μA or less |
Peak power suppression function, slope setting function, output monitor function |
0.1~10.0 seconds or 1~100 seconds (when the control method is continuous proportional method) |
Voltage pulse input DC0/12V or DC0/24V (common to all CHs) |
13kΩ or more |
16 points CTL-36-S56-20 (through type), CTL-24-CLS (clamp type) [Current transformation ratio 2,000:1] |
16 points |
![]() |
IOPD16-L-C*L7N |
Available upon quote |
DC20.4~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Accuracy: ±2% OF READING or ±1.0A, whichever is greater *CT accuracy not included |
9,600bps, 19,200bps, 38,400bps, 57,600bps |
RS-422A [4-wire] MODBUS protocol |
RS-422A 4-wire half-duplex multidrop connection |
50Hz±2Hz or 60Hz±2Hz |
1/2 cycle of load power supply cycle |
85V~242V AC |
1 point |
Accuracy: ±4% OF READING |
Heater burnout alarm (HBA) / Output current upper limit alarm / SSR short circuit abnormality alarm / Output shortage alarm / Load power supply voltage abnormality alarm / Load power supply frequency abnormality alarm |
1 cycle of load power supply cycle |
31 units |
Half-duplex step synchronization type |
Transistor output (source method) |
Zero cross control (continuous proportion) |
±1% OF SPAN (accuracy of captured manipulated variable) |
Time proportional cycle setting 0.1~10.0 seconds: approx. 1/100~1/10,000 |
Upper controller transistor (open collector) output (sink method) Input pulse L active |
None (no initial setting specified) |
DC8~30V |
100mA |
0.5V or less (at allowable load current) |
100μA or less |
Peak power suppression function, slope setting function, output monitor function |
0.1~10.0 seconds or 1~100 seconds (when the control method is continuous proportional method) |
Voltage pulse input DC0/12V or DC0/24V (common to all CHs) |
13kΩ or more |
16 points CTL-36-S56-20 (through type), CTL-24-CLS (clamp type) [Current transformation ratio 2,000:1] |
16 points |
![]() |
IOPD16-L-C*F6N |
Available upon quote |
DC20.4~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Accuracy: ±2% OF READING or ±1.0A, whichever is greater *CT accuracy not included |
9,600bps, 19,200bps, 38,400bps, 57,600bps |
RS-485 [2-wire] MODBUS protocol |
RS-485 2-wire half-duplex multidrop connection |
50Hz±2Hz or 60Hz±2Hz |
1/2 cycle of load power supply cycle |
85V~242V AC |
1 point |
Accuracy: ±4% OF READING |
Heater burnout alarm (HBA) / Output current upper limit alarm / SSR short circuit abnormality alarm / Output shortage alarm / Load power supply voltage abnormality alarm / Load power supply frequency abnormality alarm |
1 cycle of load power supply cycle |
31 units |
Half-duplex step synchronization type |
Transistor output (source method) |
Zero cross control (continuous proportion) |
±1% OF SPAN (accuracy of captured manipulated variable) |
Time proportional cycle setting 0.1~10.0 seconds: approx. 1/100~1/10,000 |
Upper controller transistor (open collector) output (sink method) Input pulse L active |
None (no initial setting specified) |
DC8~30V |
100mA |
0.5V or less (at allowable load current) |
100μA or less |
Peak power suppression function, slope setting function, output monitor function |
0.1~10.0 seconds or 1~100 seconds (when the control method is continuous proportional method) |
Voltage pulse input DC0/12V or DC0/24V (common to all CHs) |
13kΩ or more |
16 points CTL-24-CLSF (clamp type) [Current transformation ratio 3,000:1] |
16 points |
![]() |
IOPD16-L-C*F7N |
Available upon quote |
DC20.4~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Accuracy: ±2% OF READING or ±1.0A, whichever is greater *CT accuracy not included |
9,600bps, 19,200bps, 38,400bps, 57,600bps |
RS-422A [4-wire] MODBUS protocol |
RS-422A 4-wire half-duplex multidrop connection |
50Hz±2Hz or 60Hz±2Hz |
1/2 cycle of load power supply cycle |
85V~242V AC |
1 point |
Accuracy: ±4% OF READING |
Heater burnout alarm (HBA) / Output current upper limit alarm / SSR short circuit abnormality alarm / Output shortage alarm / Load power supply voltage abnormality alarm / Load power supply frequency abnormality alarm |
1 cycle of load power supply cycle |
31 units |
Half-duplex step synchronization type |
Transistor output (source method) |
Zero cross control (continuous proportion) |
±1% OF SPAN (accuracy of captured manipulated variable) |
Time proportional cycle setting 0.1~10.0 seconds: approx. 1/100~1/10,000 |
Upper controller transistor (open collector) output (sink method) Input pulse L active |
None (no initial setting specified) |
DC8~30V |
100mA |
0.5V or less (at allowable load current) |
100μA or less |
Peak power suppression function, slope setting function, output monitor function |
0.1~10.0 seconds or 1~100 seconds (when the control method is continuous proportional method) |
Voltage pulse input DC0/12V or DC0/24V (common to all CHs) |
13kΩ or more |
16 points CTL-24-CLSF (clamp type) [Current transformation ratio 3,000:1] |
16 points |