Product
Heater burnout alarm with built-in MCU for single-phase/three-phase power regulator (DIN rail mounting type) HBA-T120/HBA-T130Handling Company
RKC INSTRUMENTCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Alarm output | Alarm setting accuracy | Applicable control method | Insulation resistance | Load current | Load setting accuracy | Mass | Permissible ambient humidity | Permissible ambient temperature | Power supply voltage | Settable range | Type | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HBA-T120P-5 |
Available upon quote | 1 point, relay contact output, AC220V, 1A (resistive load) |
Within ±3% of the rated capacity of the alarm body *However, if the load voltage is 30% or less of the rating, it will be outside the accuracy range. |
For phase control system | DC500V 50MΩ between each input/output terminal | 5A (using current detector MCTL-6-P-N) | Within ±3% of the rated capacity of the alarm body | Approximately 300g | 45~85%RH (no condensation) | 0~50℃ | AC90~242V (including power supply voltage fluctuation), 50/60Hz common (rated AC100~220V) | Set at a current reduction rate of 0 to 30% of the rated capacity of the alarm body (0 to 15% of alarm set value x 2) | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T120P-30 |
Available upon quote | 1 point, relay contact output, AC220V, 1A (resistive load) |
Within ±3% of the rated capacity of the alarm body *However, if the load voltage is 30% or less of the rating, it will be outside the accuracy range. |
For phase control system | DC500V 50MΩ between each input/output terminal | 30A (using current detector MCTL-6-P-N) | Within ±3% of the rated capacity of the alarm body | Approximately 300g | 45~85%RH (no condensation) | 0~50℃ | AC90~242V (including power supply voltage fluctuation), 50/60Hz common (rated AC100~220V) | Set at a current reduction rate of 0 to 30% of the rated capacity of the alarm body (0 to 15% of alarm set value x 2) | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T120P-100 |
Available upon quote | 1 point, relay contact output, AC220V, 1A (resistive load) |
Within ±3% of the rated capacity of the alarm body *However, if the load voltage is 30% or less of the rating, it will be outside the accuracy range. |
For phase control system | DC500V 50MΩ between each input/output terminal | 100A (using current detector MCTL-12-S56-10L-N) | Within ±3% of the rated capacity of the alarm body | Approximately 300g | 45~85%RH (no condensation) | 0~50℃ | AC90~242V (including power supply voltage fluctuation), 50/60Hz common (rated AC100~220V) | Set at a current reduction rate of 0 to 30% of the rated capacity of the alarm body (0 to 15% of alarm set value x 2) | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T120Z-5 |
Available upon quote | 1 point, relay contact output, AC220V, 1A (resistive load) |
Within ±3% of the rated capacity of the alarm body *However, if the load voltage is 30% or less of the rating, it will be outside the accuracy range. |
For zero cross control system | DC500V 50MΩ between each input/output terminal | 5A (using current detector MCTL-6-P-N) | Within ±3% of the rated capacity of the alarm body | Approximately 300g | 45~85%RH (no condensation) | 0~50℃ | AC90~242V (including power supply voltage fluctuation), 50/60Hz common (rated AC100~220V) | Set at a current reduction rate of 0 to 30% of the rated capacity of the alarm body (0 to 15% of alarm set value x 2) | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T120Z-30 |
Available upon quote | 1 point, relay contact output, AC220V, 1A (resistive load) |
Within ±3% of the rated capacity of the alarm body *However, if the load voltage is 30% or less of the rating, it will be outside the accuracy range. |
For zero cross control system | DC500V 50MΩ between each input/output terminal | 30A (using current detector MCTL-6-P-N) | Within ±3% of the rated capacity of the alarm body | Approximately 300g | 45~85%RH (no condensation) | 0~50℃ | AC90~242V (including power supply voltage fluctuation), 50/60Hz common (rated AC100~220V) | Set at a current reduction rate of 0 to 30% of the rated capacity of the alarm body (0 to 15% of alarm set value x 2) | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T120Z-100 |
Available upon quote | 1 point, relay contact output, AC220V, 1A (resistive load) |
Within ±3% of the rated capacity of the alarm body *However, if the load voltage is 30% or less of the rating, it will be outside the accuracy range. |
For zero cross control system | DC500V 50MΩ between each input/output terminal | 100A (using current detector MCTL-12-S56-10L-N) | Within ±3% of the rated capacity of the alarm body | Approximately 300g | 45~85%RH (no condensation) | 0~50℃ | AC90~242V (including power supply voltage fluctuation), 50/60Hz common (rated AC100~220V) | Set at a current reduction rate of 0 to 30% of the rated capacity of the alarm body (0 to 15% of alarm set value x 2) | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T130P-5 |
Available upon quote | 1 point, relay contact output, AC220V, 1A (resistive load) |
Within ±3% of the rated capacity of the alarm body *However, if the load voltage is 30% or less of the rating, it will be outside the accuracy range. |
For phase control system | DC500V 50MΩ between each input/output terminal | 5A (using current detector MCTL-6-P-N) | Within ±3% of the rated capacity of the alarm body | Approximately 350g | 45~85%RH (no condensation) | 0~50℃ | AC90~242V (including power supply voltage fluctuation), 50/60Hz common (rated AC100~220V) | Set at a current reduction rate of 0 to 30% of the rated capacity of the alarm body (0 to 15% of alarm set value x 2) | For thyristor power regulator drive control system (for three-phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T130P-30 |
Available upon quote | 1 point, relay contact output, AC220V, 1A (resistive load) |
Within ±3% of the rated capacity of the alarm body *However, if the load voltage is 30% or less of the rating, it will be outside the accuracy range. |
For phase control system | DC500V 50MΩ between each input/output terminal | 30A (using current detector MCTL-6-P-N) | Within ±3% of the rated capacity of the alarm body | Approximately 350g | 45~85%RH (no condensation) | 0~50℃ | AC90~242V (including power supply voltage fluctuation), 50/60Hz common (rated AC100~220V) | Set at a current reduction rate of 0 to 30% of the rated capacity of the alarm body (0 to 15% of alarm set value x 2) | For thyristor power regulator drive control system (for three-phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T130P-100 |
Available upon quote | 1 point, relay contact output, AC220V, 1A (resistive load) |
Within ±3% of the rated capacity of the alarm body *However, if the load voltage is 30% or less of the rating, it will be outside the accuracy range. |
For phase control system | DC500V 50MΩ between each input/output terminal | 100A (using current detector MCTL-12-S56-10L-N) | Within ±3% of the rated capacity of the alarm body | Approximately 350g | 45~85%RH (no condensation) | 0~50℃ | AC90~242V (including power supply voltage fluctuation), 50/60Hz common (rated AC100~220V) | Set at a current reduction rate of 0 to 30% of the rated capacity of the alarm body (0 to 15% of alarm set value x 2) | For thyristor power regulator drive control system (for three-phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T130Z-5 |
Available upon quote | 1 point, relay contact output, AC220V, 1A (resistive load) |
Within ±3% of the rated capacity of the alarm body *However, if the load voltage is 30% or less of the rating, it will be outside the accuracy range. |
For zero cross control system | DC500V 50MΩ between each input/output terminal | 5A (using current detector MCTL-6-P-N) | Within ±3% of the rated capacity of the alarm body | Approximately 350g | 45~85%RH (no condensation) | 0~50℃ | AC90~242V (including power supply voltage fluctuation), 50/60Hz common (rated AC100~220V) | Set at a current reduction rate of 0 to 30% of the rated capacity of the alarm body (0 to 15% of alarm set value x 2) | For thyristor power regulator drive control system (for three-phase) | AC1,500V between each input/output terminal for 1 minute |
Click on the part number for more information about each product