Product
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33Handling Company
RKC INSTRUMENTCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Alarm output | Alarm sensitivity | Applicable control method | Detectable load current | Input type | Insulation resistance | Load current | Load current | Load setting accuracy | Mass | Permissible ambient humidity | Permissible ambient temperature | Power consumption | Power supply voltage | Settable range | Type | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HBA-T22P-5 |
Available upon quote | 2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
When the current changes by 10% or more of the load capacity *However, it is uncertain for changes within 10% |
For phase control system | AC5A, 10A, 20A, 30A (depending on the rating of the main unit) | Load voltage and current detector (CTL-6-P-N) | DC500V 50MΩ between each input/output terminal | 5A | - | ±3% to load setting value | Approximately 400g | 45~85%RH (no condensation) | 0~50℃ | 1.2VA or less | AC100/110V and AC200/220V, 50/60Hz common | 50~100% of main unit rated value | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T22P-10 |
Available upon quote | 2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
When the current changes by 10% or more of the load capacity *However, it is uncertain for changes within 10% |
For phase control system | AC5A, 10A, 20A, 30A (depending on the rating of the main unit) | Load voltage and current detector (CTL-6-P-N) | DC500V 50MΩ between each input/output terminal | - | 10A | ±3% to load setting value | Approximately 400g | 45~85%RH (no condensation) | 0~50℃ | 1.2VA or less | AC100/110V and AC200/220V, 50/60Hz common | 50~100% of main unit rated value | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T22P-20 |
Available upon quote | 2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
When the current changes by 10% or more of the load capacity *However, it is uncertain for changes within 10% |
For phase control system | AC5A, 10A, 20A, 30A (depending on the rating of the main unit) | Load voltage and current detector (CTL-6-P-N) | DC500V 50MΩ between each input/output terminal | - | 20A | ±3% to load setting value | Approximately 400g | 45~85%RH (no condensation) | 0~50℃ | 1.2VA or less | AC100/110V and AC200/220V, 50/60Hz common | 50~100% of main unit rated value | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T22P-30 |
Available upon quote | 2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
When the current changes by 10% or more of the load capacity *However, it is uncertain for changes within 10% |
For phase control system | AC5A, 10A, 20A, 30A (depending on the rating of the main unit) | Load voltage and current detector (CTL-6-P-N) | DC500V 50MΩ between each input/output terminal | - | 30A | ±3% to load setting value | Approximately 400g | 45~85%RH (no condensation) | 0~50℃ | 1.2VA or less | AC100/110V and AC200/220V, 50/60Hz common | 50~100% of main unit rated value | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T22Z-5 |
Available upon quote | 2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
When the current changes by 10% or more of the load capacity *However, it is uncertain for changes within 10% |
For zero cross control system | AC5A, 10A, 20A, 30A (depending on the rating of the main unit) | Load voltage and current detector (CTL-6-P-N) | DC500V 50MΩ between each input/output terminal | - | 5A | ±3% to load setting value | Approximately 400g | 45~85%RH (no condensation) | 0~50℃ | 1.2VA or less | AC100/110V and AC200/220V, 50/60Hz common | 50~100% of main unit rated value | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T22Z-10 |
Available upon quote | 2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
When the current changes by 10% or more of the load capacity *However, it is uncertain for changes within 10% |
For zero cross control system | AC5A, 10A, 20A, 30A (depending on the rating of the main unit) | Load voltage and current detector (CTL-6-P-N) | DC500V 50MΩ between each input/output terminal | - | 10A | ±3% to load setting value | Approximately 400g | 45~85%RH (no condensation) | 0~50℃ | 1.2VA or less | AC100/110V and AC200/220V, 50/60Hz common | 50~100% of main unit rated value | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T22Z-20 |
Available upon quote | 2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
When the current changes by 10% or more of the load capacity *However, it is uncertain for changes within 10% |
For zero cross control system | AC5A, 10A, 20A, 30A (depending on the rating of the main unit) | Load voltage and current detector (CTL-6-P-N) | DC500V 50MΩ between each input/output terminal | - | 20A | ±3% to load setting value | Approximately 400g | 45~85%RH (no condensation) | 0~50℃ | 1.2VA or less | AC100/110V and AC200/220V, 50/60Hz common | 50~100% of main unit rated value | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T22Z-30 |
Available upon quote | 2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
When the current changes by 10% or more of the load capacity *However, it is uncertain for changes within 10% |
For zero cross control system | AC5A, 10A, 20A, 30A (depending on the rating of the main unit) | Load voltage and current detector (CTL-6-P-N) | DC500V 50MΩ between each input/output terminal | - | 30A | ±3% to load setting value | Approximately 400g | 45~85%RH (no condensation) | 0~50℃ | 1.2VA or less | AC100/110V and AC200/220V, 50/60Hz common | 50~100% of main unit rated value | For thyristor power regulator drive control system (single phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T32P-5 |
Available upon quote | 2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
When the current changes by 15% or more of the load capacity *However, it is uncertain for changes within 15% |
For phase control system | AC5A, 10A, 20A, 30A (depending on the rating of the main unit) | Load voltage and current detector (CTL-6-P-N) | DC500V 50MΩ between each input/output terminal | - | 5A | ±3% to load setting value | Approximately 400g | 45~85%RH (no condensation) | 0~50℃ | 1.2VA or less | AC100/110V and AC200/220V, 50/60Hz common | 50~100% of main unit rated value | For thyristor power regulator drive control system (for three-phase) | AC1,500V between each input/output terminal for 1 minute | |
HBA-T32P-10 |
Available upon quote | 2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
When the current changes by 15% or more of the load capacity *However, it is uncertain for changes within 15% |
For phase control system | AC5A, 10A, 20A, 30A (depending on the rating of the main unit) | Load voltage and current detector (CTL-6-P-N) | DC500V 50MΩ between each input/output terminal | - | 10A | ±3% to load setting value | Approximately 400g | 45~85%RH (no condensation) | 0~50℃ | 1.2VA or less | AC100/110V and AC200/220V, 50/60Hz common | 50~100% of main unit rated value | For thyristor power regulator drive control system (for three-phase) | AC1,500V between each input/output terminal for 1 minute |
Click on the part number for more information about each product