Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33-HBA-T22P-5
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33-RKC INSTRUMENT

Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33
RKC INSTRUMENT


About This Product

■What is a heater burnout alarm? This is a device that monitors the current value flowing to the heater with a CT (current detector) and outputs an output through a contact when the heater is disconnected. We offer models whose controller output supports relay contact, SSR drive, phase control, zero cross control, etc. Panel mounting or DIN rail mounting is possible. ■Main features ・Heater burnout alarm for single-phase or three-phase power regulators ・Can be used for phase control, zero cross control, relay contact, and SSR drive ・Compatible CT: CTL-6-P-N (HBA-T22/HBA-T32), CTL-18S-N (HBA-T23/HBA-T33) *For three-phase use, use two CTs. ■HBA-T22 (for single phase) Used for phase control and zero-cross control using a single-phase thyristor power regulator. *Relay contact/SSR drive control system also available ■HBA-T32 (for three-phase) Used for phase control and zero cross control using a three-phase thyristor power regulator. *Relay contact/SSR drive control system also available ■HBA-T23 (for single phase) Used for phase control and zero-cross control using a single-phase thyristor power regulator. *Relay contact/SSR drive control system also available ■HBA-T33 (for three-phase) Used for phase control and zero cross control using a three-phase thyristor power regulator. *Relay contact/SSR drive control system also available *Other product numbers are available.

  • Product

    Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33

Share this product


220+ people viewing

Last viewed: 11 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Alarm output Alarm sensitivity Applicable control method Detectable load current Input type Insulation resistance Load current Load current Load setting accuracy Mass Permissible ambient humidity Permissible ambient temperature Power consumption Power supply voltage Settable range Type Withstand voltage
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33-Part Number-HBA-T22P-5

HBA-T22P-5

Available upon quote 2 points, relay contact output, c contact, AC200V, 3A (resistive load) When the current changes by 10% or more of the load capacity
*However, it is uncertain for changes within 10%
For phase control system AC5A, 10A, 20A, 30A (depending on the rating of the main unit) Load voltage and current detector (CTL-6-P-N) DC500V 50MΩ between each input/output terminal 5A - ±3% to load setting value Approximately 400g 45~85%RH (no condensation) 0~50℃ 1.2VA or less AC100/110V and AC200/220V, 50/60Hz common 50~100% of main unit rated value For thyristor power regulator drive control system (single phase) AC1,500V between each input/output terminal for 1 minute
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33-Part Number-HBA-T22P-10

HBA-T22P-10

Available upon quote 2 points, relay contact output, c contact, AC200V, 3A (resistive load) When the current changes by 10% or more of the load capacity
*However, it is uncertain for changes within 10%
For phase control system AC5A, 10A, 20A, 30A (depending on the rating of the main unit) Load voltage and current detector (CTL-6-P-N) DC500V 50MΩ between each input/output terminal - 10A ±3% to load setting value Approximately 400g 45~85%RH (no condensation) 0~50℃ 1.2VA or less AC100/110V and AC200/220V, 50/60Hz common 50~100% of main unit rated value For thyristor power regulator drive control system (single phase) AC1,500V between each input/output terminal for 1 minute
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33-Part Number-HBA-T22P-20

HBA-T22P-20

Available upon quote 2 points, relay contact output, c contact, AC200V, 3A (resistive load) When the current changes by 10% or more of the load capacity
*However, it is uncertain for changes within 10%
For phase control system AC5A, 10A, 20A, 30A (depending on the rating of the main unit) Load voltage and current detector (CTL-6-P-N) DC500V 50MΩ between each input/output terminal - 20A ±3% to load setting value Approximately 400g 45~85%RH (no condensation) 0~50℃ 1.2VA or less AC100/110V and AC200/220V, 50/60Hz common 50~100% of main unit rated value For thyristor power regulator drive control system (single phase) AC1,500V between each input/output terminal for 1 minute
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33-Part Number-HBA-T22P-30

HBA-T22P-30

Available upon quote 2 points, relay contact output, c contact, AC200V, 3A (resistive load) When the current changes by 10% or more of the load capacity
*However, it is uncertain for changes within 10%
For phase control system AC5A, 10A, 20A, 30A (depending on the rating of the main unit) Load voltage and current detector (CTL-6-P-N) DC500V 50MΩ between each input/output terminal - 30A ±3% to load setting value Approximately 400g 45~85%RH (no condensation) 0~50℃ 1.2VA or less AC100/110V and AC200/220V, 50/60Hz common 50~100% of main unit rated value For thyristor power regulator drive control system (single phase) AC1,500V between each input/output terminal for 1 minute
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33-Part Number-HBA-T22Z-5

HBA-T22Z-5

Available upon quote 2 points, relay contact output, c contact, AC200V, 3A (resistive load) When the current changes by 10% or more of the load capacity
*However, it is uncertain for changes within 10%
For zero cross control system AC5A, 10A, 20A, 30A (depending on the rating of the main unit) Load voltage and current detector (CTL-6-P-N) DC500V 50MΩ between each input/output terminal - 5A ±3% to load setting value Approximately 400g 45~85%RH (no condensation) 0~50℃ 1.2VA or less AC100/110V and AC200/220V, 50/60Hz common 50~100% of main unit rated value For thyristor power regulator drive control system (single phase) AC1,500V between each input/output terminal for 1 minute
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33-Part Number-HBA-T22Z-10

HBA-T22Z-10

Available upon quote 2 points, relay contact output, c contact, AC200V, 3A (resistive load) When the current changes by 10% or more of the load capacity
*However, it is uncertain for changes within 10%
For zero cross control system AC5A, 10A, 20A, 30A (depending on the rating of the main unit) Load voltage and current detector (CTL-6-P-N) DC500V 50MΩ between each input/output terminal - 10A ±3% to load setting value Approximately 400g 45~85%RH (no condensation) 0~50℃ 1.2VA or less AC100/110V and AC200/220V, 50/60Hz common 50~100% of main unit rated value For thyristor power regulator drive control system (single phase) AC1,500V between each input/output terminal for 1 minute
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33-Part Number-HBA-T22Z-20

HBA-T22Z-20

Available upon quote 2 points, relay contact output, c contact, AC200V, 3A (resistive load) When the current changes by 10% or more of the load capacity
*However, it is uncertain for changes within 10%
For zero cross control system AC5A, 10A, 20A, 30A (depending on the rating of the main unit) Load voltage and current detector (CTL-6-P-N) DC500V 50MΩ between each input/output terminal - 20A ±3% to load setting value Approximately 400g 45~85%RH (no condensation) 0~50℃ 1.2VA or less AC100/110V and AC200/220V, 50/60Hz common 50~100% of main unit rated value For thyristor power regulator drive control system (single phase) AC1,500V between each input/output terminal for 1 minute
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33-Part Number-HBA-T22Z-30

HBA-T22Z-30

Available upon quote 2 points, relay contact output, c contact, AC200V, 3A (resistive load) When the current changes by 10% or more of the load capacity
*However, it is uncertain for changes within 10%
For zero cross control system AC5A, 10A, 20A, 30A (depending on the rating of the main unit) Load voltage and current detector (CTL-6-P-N) DC500V 50MΩ between each input/output terminal - 30A ±3% to load setting value Approximately 400g 45~85%RH (no condensation) 0~50℃ 1.2VA or less AC100/110V and AC200/220V, 50/60Hz common 50~100% of main unit rated value For thyristor power regulator drive control system (single phase) AC1,500V between each input/output terminal for 1 minute
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33-Part Number-HBA-T32P-5

HBA-T32P-5

Available upon quote 2 points, relay contact output, c contact, AC200V, 3A (resistive load) When the current changes by 15% or more of the load capacity
*However, it is uncertain for changes within 15%
For phase control system AC5A, 10A, 20A, 30A (depending on the rating of the main unit) Load voltage and current detector (CTL-6-P-N) DC500V 50MΩ between each input/output terminal - 5A ±3% to load setting value Approximately 400g 45~85%RH (no condensation) 0~50℃ 1.2VA or less AC100/110V and AC200/220V, 50/60Hz common 50~100% of main unit rated value For thyristor power regulator drive control system (for three-phase) AC1,500V between each input/output terminal for 1 minute
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33-Part Number-HBA-T32P-10

HBA-T32P-10

Available upon quote 2 points, relay contact output, c contact, AC200V, 3A (resistive load) When the current changes by 15% or more of the load capacity
*However, it is uncertain for changes within 15%
For phase control system AC5A, 10A, 20A, 30A (depending on the rating of the main unit) Load voltage and current detector (CTL-6-P-N) DC500V 50MΩ between each input/output terminal - 10A ±3% to load setting value Approximately 400g 45~85%RH (no condensation) 0~50℃ 1.2VA or less AC100/110V and AC200/220V, 50/60Hz common 50~100% of main unit rated value For thyristor power regulator drive control system (for three-phase) AC1,500V between each input/output terminal for 1 minute

Click on the part number for more information about each product