Product
Heater burnout alarm for single-phase/three-phase power regulators (panel mounting type) HBA-T22/HBA-T32/HBA-T23/HBA-T33Handling Company
RKC INSTRUMENTCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply voltage | Applicable control method | Mass | Load current | Load setting accuracy | Alarm sensitivity | Alarm output | Permissible ambient humidity | Permissible ambient temperature | Settable range | Withstand voltage | Insulation resistance | Power consumption | Detectable load current | Input type | Type | Load current |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HBA-T22P-5 |
Available upon quote |
AC100/110V and AC200/220V, 50/60Hz common |
For phase control system |
Approximately 400g |
- |
±3% to load setting value |
When the current changes by 10% or more of the load capacity |
2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
45~85%RH (no condensation) |
0~50℃ |
50~100% of main unit rated value |
AC1,500V between each input/output terminal for 1 minute |
DC500V 50MΩ between each input/output terminal |
1.2VA or less |
AC5A, 10A, 20A, 30A (depending on the rating of the main unit) |
Load voltage and current detector (CTL-6-P-N) |
For thyristor power regulator drive control system (single phase) |
5A |
|
HBA-T22P-10 |
Available upon quote |
AC100/110V and AC200/220V, 50/60Hz common |
For phase control system |
Approximately 400g |
10A |
±3% to load setting value |
When the current changes by 10% or more of the load capacity |
2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
45~85%RH (no condensation) |
0~50℃ |
50~100% of main unit rated value |
AC1,500V between each input/output terminal for 1 minute |
DC500V 50MΩ between each input/output terminal |
1.2VA or less |
AC5A, 10A, 20A, 30A (depending on the rating of the main unit) |
Load voltage and current detector (CTL-6-P-N) |
For thyristor power regulator drive control system (single phase) |
- | |
HBA-T22P-20 |
Available upon quote |
AC100/110V and AC200/220V, 50/60Hz common |
For phase control system |
Approximately 400g |
20A |
±3% to load setting value |
When the current changes by 10% or more of the load capacity |
2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
45~85%RH (no condensation) |
0~50℃ |
50~100% of main unit rated value |
AC1,500V between each input/output terminal for 1 minute |
DC500V 50MΩ between each input/output terminal |
1.2VA or less |
AC5A, 10A, 20A, 30A (depending on the rating of the main unit) |
Load voltage and current detector (CTL-6-P-N) |
For thyristor power regulator drive control system (single phase) |
- | |
HBA-T22P-30 |
Available upon quote |
AC100/110V and AC200/220V, 50/60Hz common |
For phase control system |
Approximately 400g |
30A |
±3% to load setting value |
When the current changes by 10% or more of the load capacity |
2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
45~85%RH (no condensation) |
0~50℃ |
50~100% of main unit rated value |
AC1,500V between each input/output terminal for 1 minute |
DC500V 50MΩ between each input/output terminal |
1.2VA or less |
AC5A, 10A, 20A, 30A (depending on the rating of the main unit) |
Load voltage and current detector (CTL-6-P-N) |
For thyristor power regulator drive control system (single phase) |
- | |
HBA-T22Z-5 |
Available upon quote |
AC100/110V and AC200/220V, 50/60Hz common |
For zero cross control system |
Approximately 400g |
5A |
±3% to load setting value |
When the current changes by 10% or more of the load capacity |
2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
45~85%RH (no condensation) |
0~50℃ |
50~100% of main unit rated value |
AC1,500V between each input/output terminal for 1 minute |
DC500V 50MΩ between each input/output terminal |
1.2VA or less |
AC5A, 10A, 20A, 30A (depending on the rating of the main unit) |
Load voltage and current detector (CTL-6-P-N) |
For thyristor power regulator drive control system (single phase) |
- | |
HBA-T22Z-10 |
Available upon quote |
AC100/110V and AC200/220V, 50/60Hz common |
For zero cross control system |
Approximately 400g |
10A |
±3% to load setting value |
When the current changes by 10% or more of the load capacity |
2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
45~85%RH (no condensation) |
0~50℃ |
50~100% of main unit rated value |
AC1,500V between each input/output terminal for 1 minute |
DC500V 50MΩ between each input/output terminal |
1.2VA or less |
AC5A, 10A, 20A, 30A (depending on the rating of the main unit) |
Load voltage and current detector (CTL-6-P-N) |
For thyristor power regulator drive control system (single phase) |
- | |
HBA-T22Z-20 |
Available upon quote |
AC100/110V and AC200/220V, 50/60Hz common |
For zero cross control system |
Approximately 400g |
20A |
±3% to load setting value |
When the current changes by 10% or more of the load capacity |
2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
45~85%RH (no condensation) |
0~50℃ |
50~100% of main unit rated value |
AC1,500V between each input/output terminal for 1 minute |
DC500V 50MΩ between each input/output terminal |
1.2VA or less |
AC5A, 10A, 20A, 30A (depending on the rating of the main unit) |
Load voltage and current detector (CTL-6-P-N) |
For thyristor power regulator drive control system (single phase) |
- | |
HBA-T22Z-30 |
Available upon quote |
AC100/110V and AC200/220V, 50/60Hz common |
For zero cross control system |
Approximately 400g |
30A |
±3% to load setting value |
When the current changes by 10% or more of the load capacity |
2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
45~85%RH (no condensation) |
0~50℃ |
50~100% of main unit rated value |
AC1,500V between each input/output terminal for 1 minute |
DC500V 50MΩ between each input/output terminal |
1.2VA or less |
AC5A, 10A, 20A, 30A (depending on the rating of the main unit) |
Load voltage and current detector (CTL-6-P-N) |
For thyristor power regulator drive control system (single phase) |
- | |
HBA-T32P-5 |
Available upon quote |
AC100/110V and AC200/220V, 50/60Hz common |
For phase control system |
Approximately 400g |
5A |
±3% to load setting value |
When the current changes by 15% or more of the load capacity |
2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
45~85%RH (no condensation) |
0~50℃ |
50~100% of main unit rated value |
AC1,500V between each input/output terminal for 1 minute |
DC500V 50MΩ between each input/output terminal |
1.2VA or less |
AC5A, 10A, 20A, 30A (depending on the rating of the main unit) |
Load voltage and current detector (CTL-6-P-N) |
For thyristor power regulator drive control system (for three-phase) |
- | |
HBA-T32P-10 |
Available upon quote |
AC100/110V and AC200/220V, 50/60Hz common |
For phase control system |
Approximately 400g |
10A |
±3% to load setting value |
When the current changes by 15% or more of the load capacity |
2 points, relay contact output, c contact, AC200V, 3A (resistive load) |
45~85%RH (no condensation) |
0~50℃ |
50~100% of main unit rated value |
AC1,500V between each input/output terminal for 1 minute |
DC500V 50MΩ between each input/output terminal |
1.2VA or less |
AC5A, 10A, 20A, 30A (depending on the rating of the main unit) |
Load voltage and current detector (CTL-6-P-N) |
For thyristor power regulator drive control system (for three-phase) |
- |