Product
Three-phase power regulator (thyristor unit SCR) THW-AHandling Company
RKC INSTRUMENTCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Absolute humidity | Accessories | Applicable load Zero cross control | Applicable load phase control | Base up setting (output bias) | Control method | Cooling method | Fast-acting fuse | Gradient setting | Input signal | Installation method | Insulation resistance | Insulation voltage | Manual configuration | Mass | Minimum load current | Optional features | Output limiter (lower limit) | Output limiter (upper limit) | Output limiter at startup (upper limit) | Output limiter time at startup | Output mode | Output voltage range | Permissible ambient humidity | Permissible ambient temperature | Permissible frequency variation | Power consumption | Power frequency | Power supply voltage | Rated current |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
THW-A1PZ020-4*NNN-1 |
Available upon quote | MAX.W.C 29.3g/m3 dry air at 101.3kPa | 1 setting device (volume, knob, scale plate) + input/output connector (plug side) included | Linearity (R: resistance) Load | Linearity (R: resistance) Load, transformer primary side control (magnetic flux density: approx. 8,000 Gauss or less) | 0.0~100.0% (front key) | Phase control/zero cross control method (switchable) Factory setting: Phase control | Natural cooling | No fast-acting fuse | 0.0~100.0% [Front keys, external setting device (volume)] | DC0~5V | Vertical mounting | Between main circuit terminal, power supply terminal and heatsink: 20MΩ or more, DC500V | Between main circuit terminal, power supply terminal and heatsink: AC2,000V, 1 minute | 0.0~100.0% [Front keys, external setting device (volume)] | Approximately 5.8kg | 1A | No optional features | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~600.0 seconds (front key) | Standard (phase angle proportional, voltage proportional, voltage squared) | 0~98% of rated voltage | 5~95%RH (no condensation) |
Performance guarantee range: 0~+40℃ Guaranteed operation range: -15~+55℃ |
50Hz±1Hz,60Hz±1Hz (performance guaranteed) 45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed) |
17 VA or less | 50/60Hz shared (automatic detection) | AC200~240V | AC20A | |
THW-A1PZ020-4*NNN-2 |
Available upon quote | MAX.W.C 29.3g/m3 dry air at 101.3kPa | 2 setting devices (volume, knob, scale plate) + input/output connector (plug side) included | Linearity (R: resistance) Load | Linearity (R: resistance) Load, transformer primary side control (magnetic flux density: approx. 8,000 Gauss or less) | 0.0~100.0% (front key) | Phase control/zero cross control method (switchable) Factory setting: Phase control | Natural cooling | No fast-acting fuse | 0.0~100.0% [Front keys, external setting device (volume)] | DC0~5V | Vertical mounting | Between main circuit terminal, power supply terminal and heatsink: 20MΩ or more, DC500V | Between main circuit terminal, power supply terminal and heatsink: AC2,000V, 1 minute | 0.0~100.0% [Front keys, external setting device (volume)] | Approximately 5.8kg | 1A | No optional features | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~600.0 seconds (front key) | Standard (phase angle proportional, voltage proportional, voltage squared) | 0~98% of rated voltage | 5~95%RH (no condensation) |
Performance guarantee range: 0~+40℃ Guaranteed operation range: -15~+55℃ |
50Hz±1Hz,60Hz±1Hz (performance guaranteed) 45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed) |
17 VA or less | 50/60Hz shared (automatic detection) | AC200~240V | AC20A | |
THW-A1PZ020-4*NNN-9 |
Available upon quote | MAX.W.C 29.3g/m3 dry air at 101.3kPa | Input/output connector (plug side) included | Linearity (R: resistance) Load | Linearity (R: resistance) Load, transformer primary side control (magnetic flux density: approx. 8,000 Gauss or less) | 0.0~100.0% (front key) | Phase control/zero cross control method (switchable) Factory setting: Phase control | Natural cooling | No fast-acting fuse | 0.0~100.0% [Front keys, external setting device (volume)] | DC0~5V | Vertical mounting | Between main circuit terminal, power supply terminal and heatsink: 20MΩ or more, DC500V | Between main circuit terminal, power supply terminal and heatsink: AC2,000V, 1 minute | 0.0~100.0% [Front keys, external setting device (volume)] | Approximately 5.8kg | 1A | No optional features | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~600.0 seconds (front key) | Standard (phase angle proportional, voltage proportional, voltage squared) | 0~98% of rated voltage | 5~95%RH (no condensation) |
Performance guarantee range: 0~+40℃ Guaranteed operation range: -15~+55℃ |
50Hz±1Hz,60Hz±1Hz (performance guaranteed) 45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed) |
17 VA or less | 50/60Hz shared (automatic detection) | AC200~240V | AC20A | |
THW-A1PZ020-4*NFN-1 |
Available upon quote | MAX.W.C 29.3g/m3 dry air at 101.3kPa | 1 setting device (volume, knob, scale plate) + input/output connector (plug side) included | Linearity (R: resistance) Load | Linearity (R: resistance) Load, transformer primary side control (magnetic flux density: approx. 8,000 Gauss or less) | 0.0~100.0% (front key) | Phase control/zero cross control method (switchable) Factory setting: Phase control | Natural cooling | Built-in fast-acting fuse (fuse burnout alarm output not possible) | 0.0~100.0% [Front keys, external setting device (volume)] | DC0~5V | Vertical mounting | Between main circuit terminal, power supply terminal and heatsink: 20MΩ or more, DC500V | Between main circuit terminal, power supply terminal and heatsink: AC2,000V, 1 minute | 0.0~100.0% [Front keys, external setting device (volume)] | Approximately 5.8kg | 1A | No optional features | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~600.0 seconds (front key) | Standard (phase angle proportional, voltage proportional, voltage squared) | 0~98% of rated voltage | 5~95%RH (no condensation) |
Performance guarantee range: 0~+40℃ Guaranteed operation range: -15~+55℃ |
50Hz±1Hz,60Hz±1Hz (performance guaranteed) 45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed) |
17 VA or less | 50/60Hz shared (automatic detection) | AC200~240V | AC20A | |
THW-A1PZ020-4*NFN-2 |
Available upon quote | MAX.W.C 29.3g/m3 dry air at 101.3kPa | 2 setting devices (volume, knob, scale plate) + input/output connector (plug side) included | Linearity (R: resistance) Load | Linearity (R: resistance) Load, transformer primary side control (magnetic flux density: approx. 8,000 Gauss or less) | 0.0~100.0% (front key) | Phase control/zero cross control method (switchable) Factory setting: Phase control | Natural cooling | Built-in fast-acting fuse (fuse burnout alarm output not possible) | 0.0~100.0% [Front keys, external setting device (volume)] | DC0~5V | Vertical mounting | Between main circuit terminal, power supply terminal and heatsink: 20MΩ or more, DC500V | Between main circuit terminal, power supply terminal and heatsink: AC2,000V, 1 minute | 0.0~100.0% [Front keys, external setting device (volume)] | Approximately 5.8kg | 1A | No optional features | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~600.0 seconds (front key) | Standard (phase angle proportional, voltage proportional, voltage squared) | 0~98% of rated voltage | 5~95%RH (no condensation) |
Performance guarantee range: 0~+40℃ Guaranteed operation range: -15~+55℃ |
50Hz±1Hz,60Hz±1Hz (performance guaranteed) 45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed) |
17 VA or less | 50/60Hz shared (automatic detection) | AC200~240V | AC20A | |
THW-A1PZ020-4*NFN-9 |
Available upon quote | MAX.W.C 29.3g/m3 dry air at 101.3kPa | Input/output connector (plug side) included | Linearity (R: resistance) Load | Linearity (R: resistance) Load, transformer primary side control (magnetic flux density: approx. 8,000 Gauss or less) | 0.0~100.0% (front key) | Phase control/zero cross control method (switchable) Factory setting: Phase control | Natural cooling | Built-in fast-acting fuse (fuse burnout alarm output not possible) | 0.0~100.0% [Front keys, external setting device (volume)] | DC0~5V | Vertical mounting | Between main circuit terminal, power supply terminal and heatsink: 20MΩ or more, DC500V | Between main circuit terminal, power supply terminal and heatsink: AC2,000V, 1 minute | 0.0~100.0% [Front keys, external setting device (volume)] | Approximately 5.8kg | 1A | No optional features | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~600.0 seconds (front key) | Standard (phase angle proportional, voltage proportional, voltage squared) | 0~98% of rated voltage | 5~95%RH (no condensation) |
Performance guarantee range: 0~+40℃ Guaranteed operation range: -15~+55℃ |
50Hz±1Hz,60Hz±1Hz (performance guaranteed) 45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed) |
17 VA or less | 50/60Hz shared (automatic detection) | AC200~240V | AC20A | |
THW-A1PZ020-4*NSN-1 |
Available upon quote | MAX.W.C 29.3g/m3 dry air at 101.3kPa | 1 setting device (volume, knob, scale plate) + input/output connector (plug side) included | Linearity (R: resistance) Load | Linearity (R: resistance) Load, transformer primary side control (magnetic flux density: approx. 8,000 Gauss or less) | 0.0~100.0% (front key) | Phase control/zero cross control method (switchable) Factory setting: Phase control | Natural cooling | Built-in quick-acting fuse with micro switch for alarm output | 0.0~100.0% [Front keys, external setting device (volume)] | DC0~5V | Vertical mounting | Between main circuit terminal, power supply terminal and heatsink: 20MΩ or more, DC500V | Between main circuit terminal, power supply terminal and heatsink: AC2,000V, 1 minute | 0.0~100.0% [Front keys, external setting device (volume)] | Approximately 5.8kg | 1A | No optional features | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~600.0 seconds (front key) | Standard (phase angle proportional, voltage proportional, voltage squared) | 0~98% of rated voltage | 5~95%RH (no condensation) |
Performance guarantee range: 0~+40℃ Guaranteed operation range: -15~+55℃ |
50Hz±1Hz,60Hz±1Hz (performance guaranteed) 45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed) |
17 VA or less | 50/60Hz shared (automatic detection) | AC200~240V | AC20A | |
THW-A1PZ020-4*NSN-2 |
Available upon quote | MAX.W.C 29.3g/m3 dry air at 101.3kPa | 2 setting devices (volume, knob, scale plate) + input/output connector (plug side) included | Linearity (R: resistance) Load | Linearity (R: resistance) Load, transformer primary side control (magnetic flux density: approx. 8,000 Gauss or less) | 0.0~100.0% (front key) | Phase control/zero cross control method (switchable) Factory setting: Phase control | Natural cooling | Built-in quick-acting fuse with micro switch for alarm output | 0.0~100.0% [Front keys, external setting device (volume)] | DC0~5V | Vertical mounting | Between main circuit terminal, power supply terminal and heatsink: 20MΩ or more, DC500V | Between main circuit terminal, power supply terminal and heatsink: AC2,000V, 1 minute | 0.0~100.0% [Front keys, external setting device (volume)] | Approximately 5.8kg | 1A | No optional features | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~600.0 seconds (front key) | Standard (phase angle proportional, voltage proportional, voltage squared) | 0~98% of rated voltage | 5~95%RH (no condensation) |
Performance guarantee range: 0~+40℃ Guaranteed operation range: -15~+55℃ |
50Hz±1Hz,60Hz±1Hz (performance guaranteed) 45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed) |
17 VA or less | 50/60Hz shared (automatic detection) | AC200~240V | AC20A | |
THW-A1PZ020-4*NSN-9 |
Available upon quote | MAX.W.C 29.3g/m3 dry air at 101.3kPa | Input/output connector (plug side) included | Linearity (R: resistance) Load | Linearity (R: resistance) Load, transformer primary side control (magnetic flux density: approx. 8,000 Gauss or less) | 0.0~100.0% (front key) | Phase control/zero cross control method (switchable) Factory setting: Phase control | Natural cooling | Built-in quick-acting fuse with micro switch for alarm output | 0.0~100.0% [Front keys, external setting device (volume)] | DC0~5V | Vertical mounting | Between main circuit terminal, power supply terminal and heatsink: 20MΩ or more, DC500V | Between main circuit terminal, power supply terminal and heatsink: AC2,000V, 1 minute | 0.0~100.0% [Front keys, external setting device (volume)] | Approximately 5.8kg | 1A | No optional features | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~600.0 seconds (front key) | Standard (phase angle proportional, voltage proportional, voltage squared) | 0~98% of rated voltage | 5~95%RH (no condensation) |
Performance guarantee range: 0~+40℃ Guaranteed operation range: -15~+55℃ |
50Hz±1Hz,60Hz±1Hz (performance guaranteed) 45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed) |
17 VA or less | 50/60Hz shared (automatic detection) | AC200~240V | AC20A | |
THW-A1PZ020-4*6NN-1 |
Available upon quote | MAX.W.C 29.3g/m3 dry air at 101.3kPa | 1 setting device (volume, knob, scale plate) + input/output connector (plug side) included | Linearity (R: resistance) Load | Linearity (R: resistance) Load, transformer primary side control (magnetic flux density: approx. 8,000 Gauss or less) | 0.0~100.0% (front key) | Phase control/zero cross control method (switchable) Factory setting: Phase control | Natural cooling | No fast-acting fuse | 0.0~100.0% [Front keys, external setting device (volume)] | DC0~5V | Vertical mounting | Between main circuit terminal, power supply terminal and heatsink: 20MΩ or more, DC500V | Between main circuit terminal, power supply terminal and heatsink: AC2,000V, 1 minute | 0.0~100.0% [Front keys, external setting device (volume)] | Approximately 5.8kg | 1A | No optional features | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~100.0% (front key) | 0.0~600.0 seconds (front key) | Standard + constant voltage control (no heater burnout alarm) | 0~98% of rated voltage | 5~95%RH (no condensation) |
Performance guarantee range: 0~+40℃ Guaranteed operation range: -15~+55℃ |
50Hz±1Hz,60Hz±1Hz (performance guaranteed) 45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed) |
17 VA or less | 50/60Hz shared (automatic detection) | AC200~240V | AC20A |