Product
Single-phase power regulator (thyristor unit SCR) SSNP/SSNZHandling Company
RKC INSTRUMENTCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | 1 cycle surge-on current | Ambient humidity | Ambient temperature | Applicable load | Control method | Cooling method | Input signal | Installation method | Insulation resistance | Mass | Minimum load current | Mounting direction | Output control range | Power frequency | Power supply voltage | Rated load current | Response time | Standard additional functions | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SSNP-15F |
Available upon quote | 60Hz: 150A, 50Hz: 146A | 5~95%RH (no condensation) | -20℃~60℃ | Linearity (R: Resistance) Load (Transformer primary side control using a transformer is not possible) | Phase control | Natural cooling | DC4~20mA (input impedance 250Ω) | DIN rail or screw mounting | Between input/external volume terminal, output terminal, and case: 100MΩ or more DC500V | Approximately 260g | AC100mA | Vertical or horizontal mounting | 0~95% of rated voltage | 50/60Hz shared (automatic detection) | AC85~264V | AC15A | 1 cycle or less (without soft start) |
Soft start/down function: about 0.5~13 seconds External volume function (for manual operation) |
Between input/external volume terminal, output terminal, and case: AC2,500V for 1 minute | |
SSNP-25F |
Available upon quote |
60Hz/50Hz: 250A |
5~95%RH (no condensation) | -20℃~60℃ | Linearity (R: Resistance) Load (Transformer primary side control using a transformer is not possible) | Phase control | Natural cooling | DC4~20mA (input impedance 250Ω) | DIN rail or screw mounting | Between input/external volume terminal, output terminal, and case: 100MΩ or more DC500V | Approximately 260g | AC100mA | Vertical or horizontal mounting | 0~95% of rated voltage | 50/60Hz shared (automatic detection) | AC85~264V | AC25A | 1 cycle or less (without soft start) |
Soft start/down function: about 0.5~13 seconds External volume function (for manual operation) |
Between input/external volume terminal, output terminal, and case: AC2,500V for 1 minute | |
SSNZ-15F |
Available upon quote | 60Hz: 150A, 50Hz: 146A | 5~95%RH (no condensation) | -20℃~60℃ | Linearity (R: Resistance) Load (Transformer primary side control using a transformer is not possible) | Zero cross control | Natural cooling | DC4~20mA (input impedance 250Ω) | DIN rail or screw mounting | Between input/external volume terminal, output terminal, and case: 100MΩ or more DC500V | Approximately 260g | AC100mA | Vertical or horizontal mounting | 0~100% of rated voltage | 50/60Hz shared (automatic detection) | AC85~264V | AC15A | 1 cycle or less (without soft start) |
Soft start/down function: about 0.5~40 seconds External volume function (for manual operation) |
Between input/external volume terminal, output terminal, and case: AC2,500V for 1 minute | |
SSNZ-25F |
Available upon quote |
60Hz/50Hz: 250A |
5~95%RH (no condensation) | -20℃~60℃ | Linearity (R: Resistance) Load (Transformer primary side control using a transformer is not possible) | Zero cross control | Natural cooling | DC4~20mA (input impedance 250Ω) | DIN rail or screw mounting | Between input/external volume terminal, output terminal, and case: 100MΩ or more DC500V | Approximately 260g | AC100mA | Vertical or horizontal mounting | 0~100% of rated voltage | 50/60Hz shared (automatic detection) | AC85~264V | AC25A | 1 cycle or less (without soft start) |
Soft start/down function: about 0.5~40 seconds External volume function (for manual operation) |
Between input/external volume terminal, output terminal, and case: AC2,500V for 1 minute |
Click on the part number for more information about each product