Single-phase power regulator (thyristor unit SCR) SSNP/SSNZHandling Company
RKC INSTRUMENTCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply voltage | Power frequency | Applicable load | Mass | Withstand voltage | Insulation resistance | Standard additional functions | Minimum load current | Response time | Rated load current | Installation method | Mounting direction | Control method | Output control range | Cooling method | Input signal | Ambient humidity | Ambient temperature | 1 cycle surge-on current |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SSNP-15F |
Available upon quote |
AC85~264V |
50/60Hz shared (automatic detection) |
Linearity (R: Resistance) Load (Transformer primary side control using a transformer is not possible) |
Approximately 260g |
Between input/external volume terminal, output terminal, and case: AC2,500V for 1 minute |
Between input/external volume terminal, output terminal, and case: 100MΩ or more DC500V |
Soft start/down function: about 0.5~13 seconds |
AC100mA |
1 cycle or less (without soft start) |
AC15A |
DIN rail or screw mounting |
Vertical or horizontal mounting |
Phase control |
0~95% of rated voltage |
Natural cooling |
DC4~20mA (input impedance 250Ω) |
5~95%RH (no condensation) |
-20℃~60℃ |
60Hz: 150A, 50Hz: 146A |
|
SSNP-25F |
Available upon quote |
AC85~264V |
50/60Hz shared (automatic detection) |
Linearity (R: Resistance) Load (Transformer primary side control using a transformer is not possible) |
Approximately 260g |
Between input/external volume terminal, output terminal, and case: AC2,500V for 1 minute |
Between input/external volume terminal, output terminal, and case: 100MΩ or more DC500V |
Soft start/down function: about 0.5~13 seconds |
AC100mA |
1 cycle or less (without soft start) |
AC25A |
DIN rail or screw mounting |
Vertical or horizontal mounting |
Phase control |
0~95% of rated voltage |
Natural cooling |
DC4~20mA (input impedance 250Ω) |
5~95%RH (no condensation) |
-20℃~60℃ |
60Hz/50Hz: 250A |
|
SSNZ-15F |
Available upon quote |
AC85~264V |
50/60Hz shared (automatic detection) |
Linearity (R: Resistance) Load (Transformer primary side control using a transformer is not possible) |
Approximately 260g |
Between input/external volume terminal, output terminal, and case: AC2,500V for 1 minute |
Between input/external volume terminal, output terminal, and case: 100MΩ or more DC500V |
Soft start/down function: about 0.5~40 seconds |
AC100mA |
1 cycle or less (without soft start) |
AC15A |
DIN rail or screw mounting |
Vertical or horizontal mounting |
Zero cross control |
0~100% of rated voltage |
Natural cooling |
DC4~20mA (input impedance 250Ω) |
5~95%RH (no condensation) |
-20℃~60℃ |
60Hz: 150A, 50Hz: 146A |
|
SSNZ-25F |
Available upon quote |
AC85~264V |
50/60Hz shared (automatic detection) |
Linearity (R: Resistance) Load (Transformer primary side control using a transformer is not possible) |
Approximately 260g |
Between input/external volume terminal, output terminal, and case: AC2,500V for 1 minute |
Between input/external volume terminal, output terminal, and case: 100MΩ or more DC500V |
Soft start/down function: about 0.5~40 seconds |
AC100mA |
1 cycle or less (without soft start) |
AC25A |
DIN rail or screw mounting |
Vertical or horizontal mounting |
Zero cross control |
0~100% of rated voltage |
Natural cooling |
DC4~20mA (input impedance 250Ω) |
5~95%RH (no condensation) |
-20℃~60℃ |
60Hz/50Hz: 250A |