Single-phase power regulator (thyristor unit SCR) THV-A1-THV-A1PZ020-4*6NNNN-1
Single-phase power regulator (thyristor unit SCR) THV-A1-RKC INSTRUMENT

Single-phase power regulator (thyristor unit SCR) THV-A1
RKC INSTRUMENT


About This Product

■What is a power regulator (thyristor unit SCR)? This is a device that inputs analog signals such as 4 to 20 mA and continuously and finely adjusts the power supply to the heater. You can choose between the phase control method that controls the power waveform and the low-noise zero-cross control method that controls the power cycle. With the phase control method, by using the soft start function, it is possible to control the primary side of heaters and transformers with large inrush currents. ■Excellent responsiveness and reproducibility with digital control - Digitally controlled operation device equipped with a display and setting keys on the front. ・With a soft up (soft start)/soft down setting of 0 seconds, the response is fast and can handle high-speed temperature rises. ■Available for heaters with special characteristics Constant voltage control, constant current control, and constant power control are possible, so it can be used with heaters whose resistance value changes greatly depending on temperature changes, such as noble metals (platinum/molybdenum), superkanthal, and silicon carbide. ■Multi-memory area function The memory area function allows you to store 4 patterns of heater burnout settings, making it easy to change heater burnout alarm settings. ■Reducing the size of the transformer without limiting the magnetic flux density of the transformer (optional) The transformer primary side control function can suppress excessive currents caused by momentary power outages on the load side (transformer). When controlling the primary side of a transformer, use a transformer with primary side control function. There are no restrictions on the magnetic flux density of the transformer. ■Heater disconnection with non-linear load can be detected. - Up to 3 inflection points can be set according to the characteristics of the heater. It can also be used with loads (such as lamp heaters) that have large resistance changes due to temperature. - Automatic setting of inflection point is possible. *Other product numbers are available.

  • Product

    Single-phase power regulator (thyristor unit SCR) THV-A1

Share this product


240+ people viewing

Last viewed: 7 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Single-phase power regulator (thyristor unit SCR) THV-A1

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Absolute humidity Accessories Alarm output Applicable load Zero cross control Applicable load phase control Base up setting (output bias) Communication function Control method Cooling method Fast-acting fuse Gradient setting Heat sink temperature detection function, etc. Input sampling period Input signal Manual configuration Minimum load current Output limiter (lower limit) Output limiter (upper limit) Output limiter at startup (upper limit) Output limiter time at startup Output mode Output voltage range Permissible ambient humidity Permissible ambient temperature Permissible frequency variation Power consumption Power frequency Power supply Power supply voltage Rated current
Single-phase power regulator (thyristor unit SCR) THV-A1-Part Number-THV-A1PZ020-4*6NNNN-1

THV-A1PZ020-4*6NNNN-1

Available upon quote MAX.W.C 29.3g/m3 dry air at 101.3kPa 1 setting device (volume, knob, scale plate) + connector (plug side) included No alarm output Resistive load Resistive load, transformer primary side control -10.0~100.0% (front key) No communication function Phase control/zero cross control method (Factory: phase system) Natural cooling No fast-acting fuse 0.0~200.0% (front key)
0~100% [External setting device (volume)]
No function 0.5 cycle of power supply cycle DC0~5V 0.0~100.0% (front key)
0~100% [External setting device (volume)]
0.5A (at 98% output of rated voltage) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~600.0 seconds (front key) Standard + constant voltage control 0~98% of rated voltage 5~95%RH (no condensation) Performance guarantee range: 0~+50℃ (AC60A: 0~+45℃)
Guaranteed operation range: -15~+55℃ (AC20A, 30A, 45A, 60A, 80A, 100A)
-10~+55℃ (AC150A,200A)
50Hz±1Hz,60Hz±1Hz (performance guaranteed)
45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed)
6VA or less (at AC100V) Inrush current 10A or less
8VA or less (at AC240V) Inrush current 24A or less
50/60Hz shared (automatic detection) Single phase AC100~240V AC90~264V (including power supply voltage fluctuation) Rating: AC100~240V AC20A
Single-phase power regulator (thyristor unit SCR) THV-A1-Part Number-THV-A1PZ020-4*6NNNN-2

THV-A1PZ020-4*6NNNN-2

Available upon quote MAX.W.C 29.3g/m3 dry air at 101.3kPa 2 setting devices (volume, knob, scale plate) + connector (plug side) included No alarm output Resistive load Resistive load, transformer primary side control -10.0~100.0% (front key) No communication function Phase control/zero cross control method (Factory: phase system) Natural cooling No fast-acting fuse 0.0~200.0% (front key)
0~100% [External setting device (volume)]
No function 0.5 cycle of power supply cycle DC0~5V 0.0~100.0% (front key)
0~100% [External setting device (volume)]
0.5A (at 98% output of rated voltage) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~600.0 seconds (front key) Standard + constant voltage control 0~98% of rated voltage 5~95%RH (no condensation) Performance guarantee range: 0~+50℃ (AC60A: 0~+45℃)
Guaranteed operation range: -15~+55℃ (AC20A, 30A, 45A, 60A, 80A, 100A)
-10~+55℃ (AC150A,200A)
50Hz±1Hz,60Hz±1Hz (performance guaranteed)
45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed)
6VA or less (at AC100V) Inrush current 10A or less
8VA or less (at AC240V) Inrush current 24A or less
50/60Hz shared (automatic detection) Single phase AC100~240V AC90~264V (including power supply voltage fluctuation) Rating: AC100~240V AC20A
Single-phase power regulator (thyristor unit SCR) THV-A1-Part Number-THV-A1PZ020-4*6NNNN-9

THV-A1PZ020-4*6NNNN-9

Available upon quote MAX.W.C 29.3g/m3 dry air at 101.3kPa Input connector (plug side) included No alarm output Resistive load Resistive load, transformer primary side control -10.0~100.0% (front key) No communication function Phase control/zero cross control method (Factory: phase system) Natural cooling No fast-acting fuse 0.0~200.0% (front key)
0~100% [External setting device (volume)]
No function 0.5 cycle of power supply cycle DC0~5V 0.0~100.0% (front key)
0~100% [External setting device (volume)]
0.5A (at 98% output of rated voltage) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~600.0 seconds (front key) Standard + constant voltage control 0~98% of rated voltage 5~95%RH (no condensation) Performance guarantee range: 0~+50℃ (AC60A: 0~+45℃)
Guaranteed operation range: -15~+55℃ (AC20A, 30A, 45A, 60A, 80A, 100A)
-10~+55℃ (AC150A,200A)
50Hz±1Hz,60Hz±1Hz (performance guaranteed)
45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed)
6VA or less (at AC100V) Inrush current 10A or less
8VA or less (at AC240V) Inrush current 24A or less
50/60Hz shared (automatic detection) Single phase AC100~240V AC90~264V (including power supply voltage fluctuation) Rating: AC100~240V AC20A
Single-phase power regulator (thyristor unit SCR) THV-A1-Part Number-THV-A1PZ020-4*6NNNN-B

THV-A1PZ020-4*6NNNN-B

Available upon quote MAX.W.C 29.3g/m3 dry air at 101.3kPa Alarm output connector (plug side) included No alarm output Resistive load Resistive load, transformer primary side control -10.0~100.0% (front key) No communication function Phase control/zero cross control method (Factory: phase system) Natural cooling No fast-acting fuse 0.0~200.0% (front key)
0~100% [External setting device (volume)]
No function 0.5 cycle of power supply cycle DC0~5V 0.0~100.0% (front key)
0~100% [External setting device (volume)]
0.5A (at 98% output of rated voltage) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~600.0 seconds (front key) Standard + constant voltage control 0~98% of rated voltage 5~95%RH (no condensation) Performance guarantee range: 0~+50℃ (AC60A: 0~+45℃)
Guaranteed operation range: -15~+55℃ (AC20A, 30A, 45A, 60A, 80A, 100A)
-10~+55℃ (AC150A,200A)
50Hz±1Hz,60Hz±1Hz (performance guaranteed)
45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed)
6VA or less (at AC100V) Inrush current 10A or less
8VA or less (at AC240V) Inrush current 24A or less
50/60Hz shared (automatic detection) Single phase AC100~240V AC90~264V (including power supply voltage fluctuation) Rating: AC100~240V AC20A
Single-phase power regulator (thyristor unit SCR) THV-A1-Part Number-THV-A1PZ020-4*6NNN4-1

THV-A1PZ020-4*6NNN4-1

Available upon quote MAX.W.C 29.3g/m3 dry air at 101.3kPa 1 setting device (volume, knob, scale plate) + connector (plug side) included No alarm output Resistive load Resistive load, transformer primary side control -10.0~100.0% (front key) RS-422A Phase control/zero cross control method (Factory: phase system) Natural cooling No fast-acting fuse 0.0~200.0% (front key)
0~100% [External setting device (volume)]
No function 0.5 cycle of power supply cycle DC0~5V 0.0~100.0% (front key)
0~100% [External setting device (volume)]
0.5A (at 98% output of rated voltage) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~600.0 seconds (front key) Standard + constant voltage control 0~98% of rated voltage 5~95%RH (no condensation) Performance guarantee range: 0~+50℃ (AC60A: 0~+45℃)
Guaranteed operation range: -15~+55℃ (AC20A, 30A, 45A, 60A, 80A, 100A)
-10~+55℃ (AC150A,200A)
50Hz±1Hz,60Hz±1Hz (performance guaranteed)
45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed)
6VA or less (at AC100V) Inrush current 10A or less
8VA or less (at AC240V) Inrush current 24A or less
50/60Hz shared (automatic detection) Single phase AC100~240V AC90~264V (including power supply voltage fluctuation) Rating: AC100~240V AC20A
Single-phase power regulator (thyristor unit SCR) THV-A1-Part Number-THV-A1PZ020-4*6NNN4-2

THV-A1PZ020-4*6NNN4-2

Available upon quote MAX.W.C 29.3g/m3 dry air at 101.3kPa 2 setting devices (volume, knob, scale plate) + connector (plug side) included No alarm output Resistive load Resistive load, transformer primary side control -10.0~100.0% (front key) RS-422A Phase control/zero cross control method (Factory: phase system) Natural cooling No fast-acting fuse 0.0~200.0% (front key)
0~100% [External setting device (volume)]
No function 0.5 cycle of power supply cycle DC0~5V 0.0~100.0% (front key)
0~100% [External setting device (volume)]
0.5A (at 98% output of rated voltage) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~600.0 seconds (front key) Standard + constant voltage control 0~98% of rated voltage 5~95%RH (no condensation) Performance guarantee range: 0~+50℃ (AC60A: 0~+45℃)
Guaranteed operation range: -15~+55℃ (AC20A, 30A, 45A, 60A, 80A, 100A)
-10~+55℃ (AC150A,200A)
50Hz±1Hz,60Hz±1Hz (performance guaranteed)
45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed)
6VA or less (at AC100V) Inrush current 10A or less
8VA or less (at AC240V) Inrush current 24A or less
50/60Hz shared (automatic detection) Single phase AC100~240V AC90~264V (including power supply voltage fluctuation) Rating: AC100~240V AC20A
Single-phase power regulator (thyristor unit SCR) THV-A1-Part Number-THV-A1PZ020-4*6NNN4-9

THV-A1PZ020-4*6NNN4-9

Available upon quote MAX.W.C 29.3g/m3 dry air at 101.3kPa Input connector (plug side) included No alarm output Resistive load Resistive load, transformer primary side control -10.0~100.0% (front key) RS-422A Phase control/zero cross control method (Factory: phase system) Natural cooling No fast-acting fuse 0.0~200.0% (front key)
0~100% [External setting device (volume)]
No function 0.5 cycle of power supply cycle DC0~5V 0.0~100.0% (front key)
0~100% [External setting device (volume)]
0.5A (at 98% output of rated voltage) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~600.0 seconds (front key) Standard + constant voltage control 0~98% of rated voltage 5~95%RH (no condensation) Performance guarantee range: 0~+50℃ (AC60A: 0~+45℃)
Guaranteed operation range: -15~+55℃ (AC20A, 30A, 45A, 60A, 80A, 100A)
-10~+55℃ (AC150A,200A)
50Hz±1Hz,60Hz±1Hz (performance guaranteed)
45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed)
6VA or less (at AC100V) Inrush current 10A or less
8VA or less (at AC240V) Inrush current 24A or less
50/60Hz shared (automatic detection) Single phase AC100~240V AC90~264V (including power supply voltage fluctuation) Rating: AC100~240V AC20A
Single-phase power regulator (thyristor unit SCR) THV-A1-Part Number-THV-A1PZ020-4*6NNN4-B

THV-A1PZ020-4*6NNN4-B

Available upon quote MAX.W.C 29.3g/m3 dry air at 101.3kPa Alarm output connector (plug side) included No alarm output Resistive load Resistive load, transformer primary side control -10.0~100.0% (front key) RS-422A Phase control/zero cross control method (Factory: phase system) Natural cooling No fast-acting fuse 0.0~200.0% (front key)
0~100% [External setting device (volume)]
No function 0.5 cycle of power supply cycle DC0~5V 0.0~100.0% (front key)
0~100% [External setting device (volume)]
0.5A (at 98% output of rated voltage) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~600.0 seconds (front key) Standard + constant voltage control 0~98% of rated voltage 5~95%RH (no condensation) Performance guarantee range: 0~+50℃ (AC60A: 0~+45℃)
Guaranteed operation range: -15~+55℃ (AC20A, 30A, 45A, 60A, 80A, 100A)
-10~+55℃ (AC150A,200A)
50Hz±1Hz,60Hz±1Hz (performance guaranteed)
45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed)
6VA or less (at AC100V) Inrush current 10A or less
8VA or less (at AC240V) Inrush current 24A or less
50/60Hz shared (automatic detection) Single phase AC100~240V AC90~264V (including power supply voltage fluctuation) Rating: AC100~240V AC20A
Single-phase power regulator (thyristor unit SCR) THV-A1-Part Number-THV-A1PZ020-4*6NNN5-1

THV-A1PZ020-4*6NNN5-1

Available upon quote MAX.W.C 29.3g/m3 dry air at 101.3kPa 1 setting device (volume, knob, scale plate) + connector (plug side) included No alarm output Resistive load Resistive load, transformer primary side control -10.0~100.0% (front key) RS-485 Phase control/zero cross control method (Factory: phase system) Natural cooling No fast-acting fuse 0.0~200.0% (front key)
0~100% [External setting device (volume)]
No function 0.5 cycle of power supply cycle DC0~5V 0.0~100.0% (front key)
0~100% [External setting device (volume)]
0.5A (at 98% output of rated voltage) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~600.0 seconds (front key) Standard + constant voltage control 0~98% of rated voltage 5~95%RH (no condensation) Performance guarantee range: 0~+50℃ (AC60A: 0~+45℃)
Guaranteed operation range: -15~+55℃ (AC20A, 30A, 45A, 60A, 80A, 100A)
-10~+55℃ (AC150A,200A)
50Hz±1Hz,60Hz±1Hz (performance guaranteed)
45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed)
6VA or less (at AC100V) Inrush current 10A or less
8VA or less (at AC240V) Inrush current 24A or less
50/60Hz shared (automatic detection) Single phase AC100~240V AC90~264V (including power supply voltage fluctuation) Rating: AC100~240V AC20A
Single-phase power regulator (thyristor unit SCR) THV-A1-Part Number-THV-A1PZ020-4*6NNN5-2

THV-A1PZ020-4*6NNN5-2

Available upon quote MAX.W.C 29.3g/m3 dry air at 101.3kPa 2 setting devices (volume, knob, scale plate) + connector (plug side) included No alarm output Resistive load Resistive load, transformer primary side control -10.0~100.0% (front key) RS-485 Phase control/zero cross control method (Factory: phase system) Natural cooling No fast-acting fuse 0.0~200.0% (front key)
0~100% [External setting device (volume)]
No function 0.5 cycle of power supply cycle DC0~5V 0.0~100.0% (front key)
0~100% [External setting device (volume)]
0.5A (at 98% output of rated voltage) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~100.0% (front key) 0.0~600.0 seconds (front key) Standard + constant voltage control 0~98% of rated voltage 5~95%RH (no condensation) Performance guarantee range: 0~+50℃ (AC60A: 0~+45℃)
Guaranteed operation range: -15~+55℃ (AC20A, 30A, 45A, 60A, 80A, 100A)
-10~+55℃ (AC150A,200A)
50Hz±1Hz,60Hz±1Hz (performance guaranteed)
45~54.9Hz (50Hz) ,55~64.9Hz (60Hz) (operation guaranteed)
6VA or less (at AC100V) Inrush current 10A or less
8VA or less (at AC240V) Inrush current 24A or less
50/60Hz shared (automatic detection) Single phase AC100~240V AC90~264V (including power supply voltage fluctuation) Rating: AC100~240V AC20A

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of RKC INSTRUMENT


View more products of RKC INSTRUMENT

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree